1,650 research outputs found
Theory of deoplet vaporization in the region of the thermodynamic critical point
Droplet vaporization in region of thermodynamic critical poin
Hamiltonian and physical Hilbert space in polymer quantum mechanics
In this paper, a version of polymer quantum mechanics, which is inspired by
loop quantum gravity, is considered and shown to be equivalent, in a precise
sense, to the standard, experimentally tested, Schroedinger quantum mechanics.
The kinematical cornerstone of our framework is the so called polymer
representation of the Heisenberg-Weyl (H-W) algebra, which is the starting
point of the construction. The dynamics is constructed as a continuum limit of
effective theories characterized by a scale, and requires a renormalization of
the inner product. The result is a physical Hilbert space in which the
continuum Hamiltonian can be represented and that is unitarily equivalent to
the Schroedinger representation of quantum mechanics. As a concrete
implementation of our formalism, the simple harmonic oscillator is fully
developed.Comment: 19 pages, 2 figures. Comments and references added. Version to be
published in CQ
Matching Crop Requirements to Land Characteristics
Examples of matching crop, soil, and season are given; implications for technology transfer in the tropics are mentioned
Metallic impurities in the Cu-fraction of Ni targets prepared from NiCl2 solutions
Introduction
Copper-64 is an emerging radionuclide with applications in PET molecular imaging and/or internal therapy and it is typically produced by proton irradiation of isotopically enriched 64Ni electrodeposited on a suitable backing substrate. We recently reported a simple and efficient method for the preparation of nickel targets from electrolytic solutions of nickel chloride and boric acid [1]. Herein we report our recent research work on the analysis of metallic impurities in the copper-fraction of the radiochemical separation process.
Material and Methods
Nickel targets were prepared and processed as previously reported [1]. Briefly, the bath solution was composed of a mixture of natural NiCl2. 6H2O (135 mg/ml) and H3BO3 (15 mg/ml) and Ni was electrodeposited using a gold disk as cathode and a platinum wire as anode. The plating process was carried out at room temperature using 2 ml of bath solution (pH = 3.7) and a constant current density of 60 mA/cm2 for 1 hour. The unirradiated Ni targets were dissolved in 1–2 ml of concentrated (10M) HCl at 90 oC. After complete dissolution of the Ni layer, water was added to dilute the acid to 6M, and the solution was transferred onto a chromatographic column containing AG 1-X8 resin equilibrated with 6M HCl. The Ni , Co and Cu isotopes were separated by using the well-known chromatography of the chloro-complexes. The sample-fractions containing the Cu isotopes (15 ml, 0.1M HCl) were collected in plastic centrifuge tubes previously soaked in 1M HNO3 and rinsed with Milli-Q water (18 MΩ cm). Impurities of B, Co, Ni, Cu and Zn in these samples were determined by inductively coupled plasma-mass spectroscopy (ICP-MS) at the Department of Geosciences (Laboratory of Isotopic Studies) of the National University.
Results and Conclusions
The mass of Ni deposited in 1 h was 25.0 ± 1.0 mg (n = 3) and the current efficiency was > 75 % in all cases. The pH of the electrolytic solution tended to decrease along the electrodeposition process (3.71.6). The results of ICP-MS analysis of the Cu-fractions from the cold chromatography separation runs are shown in FIG. 1. We were particularly interested in the boron impurities as H3BO3 is used as buffer for electrodeposition of the Ni targets.
Except for the Ni impurities that were deter-mined to be in the range of ppm (mg/l), all other analyzed metallic impurities were found to be in the range of ppb (µg/l), including boron. The Co, Ni, Cu and Zn impurities determined in the Cu-fraction in this work using Ni targets electrode-posited from a NiCl2 acidic solution, are in the same order of magnitude compared with that obtained when using targets prepared from an alkaline solution [2], with the advantage of the simplicity of the electrodeposition method from NiCl2 solutions, as the target material is already recovered in the chemical form of NiCl2, enabling a simpler, one step process to prepare a new plating solution when using enriched 64Ni target material for the production of 64Cu
Ca II 8542 \AA\ brightenings induced by a solar microflare
We study small-scale brightenings in Ca II 8542 \AA\ line-core images to
determine their nature and effect on localized heating and mass transfer in
active regions. High-resolution 2D spectroscopic observations of an active
region in the Ca II 8542 \AA\ line were acquired with the GFPI attached to the
1.5-meter GREGOR telescope. Inversions of the spectra were carried out using
NICOLE. We identified three brightenings of sizes up to 2"x2". We found
evidence that the brightenings belonged to the footpoints of a microflare (MF).
The properties of the observed brightenings disqualified the scenarios of
Ellerman bombs or IRIS bombs. However, this MF shared some common properties
with flaring active-region fibrils or flaring arch filaments (FAFs): (1) FAFs
and MFs are both apparent in chromospheric and coronal layers according to the
AIA channels, and (2) both show flaring arches with lifetimes of about 3.0-3.5
min and lengths of about 20". The inversions revealed heating by 600 K at the
footpoint location in the ambient chromosphere during the impulsive phase.
Connecting the footpoints, a dark filamentary structure appeared in the Ca II
line-core images. Before the start of the MF, the spectra of this structure
already indicated average blueshifts, meaning upward motions of the plasma
along the LOS. During the impulsive phase, these velocities increased up to
-2.2 km/s. Downflows dominated at the footpoints. However, in the upper
photosphere, slight upflows occurred during the impulsive phase. Hence,
bidirectional flows are present in the footpoints of the MF. Conclusions: We
detected Ca II brightenings that coincided with the footpoint location of an
MF. The MF event led to a rise of plasma in the upper photosphere, both before
and during the impulsive phase. Excess mass, previously raised to at most
chromospheric layers, slowly drained downward along arches toward the
footpoints of the MF.Comment: Accepted for publication in Astronomy & Astrophysics, 13 pages, 6
figures, 1 online movi
Rapid and MR-Independent IK1 activation by aldosterone during ischemia-reperfusion
In ST elevation myocardial infarction (STEMI) context, clinical studies have shown the deleterious
effect of high aldosterone levels on ventricular arrhythmia occurrence and cardiac
mortality. Previous in vitro reports showed that during ischemia-reperfusion, aldosterone
modulates K+ currents involved in the holding of the resting membrane potential (RMP).
The aim of this study was to assess the electrophysiological impact of aldosterone on IK1
current during myocardial ischemia-reperfusion. We used an in vitro model of “border zone”
using right rabbit ventricle and standard microelectrode technique followed by cell-attached
recordings from freshly isolated rabbit ventricular cardiomyocytes. In microelectrode experiments,
aldosterone (10 and 100 nmol/L, n=7 respectively) increased the action potential
duration (APD) dispersion at 90% between ischemic and normoxic zones (from 95±4ms to
116±6 ms and 127±5 ms respectively, P<0.05) and reperfusion-induced sustained premature
ventricular contractions occurrence (from 2/12 to 5/7 preparations, P<0.05). Conversely,
potassium canrenoate 100 nmol/L and RU 28318 1 μmol/l alone did not affect AP
parameters and premature ventricular contractions occurrence (except Vmax which was
decreased by potassium canrenoate during simulated-ischemia). Furthermore, aldosterone
induced a RMP hyperpolarization, evoking an implication of a K+ current involved in the
holding of the RMP. Cell-attached recordings showed that aldosterone 10 nmol/L quickly
activated (within 6.2±0.4 min) a 30 pS K+-selective current, inward rectifier, with pharmacological
and biophysical properties consistent with the IK1 current (NPo =1.9±0.4 in control vs
NPo=3.0±0.4, n=10, P<0.05). These deleterious effects persisted in presence of RU 28318,
a specific MR antagonist, and were successfully prevented by potassium canrenoate, a non
specific MR antagonist, in both microelectrode and patch-clamp recordings, thus indicating
a MR-independent IK1 activation. In this ischemia-reperfusion context, aldosterone induced
rapid and MR-independent deleterious effects including an arrhythmia substrate (increased
APD90 dispersion) and triggered activities (increased premature ventricular contractions
occurrence on reperfusion) possibly related to direct IK1 activation
Fractal space-times under the microscope: A Renormalization Group view on Monte Carlo data
The emergence of fractal features in the microscopic structure of space-time
is a common theme in many approaches to quantum gravity. In this work we carry
out a detailed renormalization group study of the spectral dimension and
walk dimension associated with the effective space-times of
asymptotically safe Quantum Einstein Gravity (QEG). We discover three scaling
regimes where these generalized dimensions are approximately constant for an
extended range of length scales: a classical regime where , a
semi-classical regime where , and the UV-fixed point
regime where . On the length scales covered by
three-dimensional Monte Carlo simulations, the resulting spectral dimension is
shown to be in very good agreement with the data. This comparison also provides
a natural explanation for the apparent puzzle between the short distance
behavior of the spectral dimension reported from Causal Dynamical
Triangulations (CDT), Euclidean Dynamical Triangulations (EDT), and Asymptotic
Safety.Comment: 26 pages, 6 figure
- …