36 research outputs found

    Enhanced S-Cone Syndrome

    No full text

    Akute makul\ue4re Neuroretinopathie [Acute macular neuroretinopathy]

    No full text

    Establishment of diagnostic reference levels for dental panoramic radiography in Greece

    No full text
    The purpose of the present study was to present the national diagnostic reference levels (DRL) established for panoramic dental examinations in Greece. The establishment of DRL, as a tool for the optimisation of radiological procedures, is a requirement of national regulations. Measurements performed by the Greek Atomic Energy Commission on 90 panoramic systems have been used for the derivation of DRL values. DRL values have been proposed for exposure settings of different patient types (child, small adult and standard adult), both for film and digital imaging. The DRLs for different patient types are grouped in three categories: children, small adults (corresponding to female) and average adults (corresponding to male). Proposed DRLs for these groups are 2.2, 3.3 and 4.1 μGy, respectively. In order to investigate the correlation of DRLs with the available imaging modalities (CR, DR and film), this parameter was taken into account. DR imaging DRL is the lowest at 3.5 μGy, CR imaging the highest at 4.2 μGy and film imaging at 3.7 μGy. In order to facilitate comparison with other studies, kerma-width product values were calculated from Ki, air and field size. © The Author 2015

    Establishment of diagnostic reference levels for dental intraoral radiography

    No full text
    Diagnostic reference levels (DRLs) is a tool for the optimisation of radiological procedures. Establishment of a DRL is a requirement of national regulations. Measurements performed by the Greek Atomic Energy Commission on 529 dental intraoral radiographic facilities have been used in order to define DRLs for digital and film imaging modalities, taking into account the region of the mouth to be imaged. Thus, different DRL values have been proposed for minimum (usually incisors), maximum (usually maxillary molars) and average exposure settings, both for film and digital imaging. The results have been compared with similar studies performed in Europe and the USA and are in line with the most recent ones. ©The Author 2013. Published by Oxford University Press

    Development and applicability of a quality control phantom for dental cone-beam CT

    No full text
    Cone-beam CT (CBCT) has shown to be a useful imaging modality for various dentomaxillofacial applications. However, optimization and quality control of dental CBCT devices is hampered due to the lack of an appropriate tool for image quality assessment. To investigate the application of different image quality parameters for CBCT, a prototype polymethyl methacrylate (PMMA) cylindrical phantom with inserts for image quality analysis was developed. Applicability and reproducibility of the phantom were assessed using seven CBCT devices with different scanning protocols. Image quality parameters evaluated were: CT number correlation, contrast resolution, image homogeneity and uniformity, point spread function, and metal artifacts. Deviations of repeated measurements were between 0.0% and 3.3%. Correlation coefficients of CBCT voxel values with CT numbers ranged between 0.68 and 1.00. Contrast-to-noise ratio (CNR) values were much lower for hydroxyapatite (0 < CNR < 7.7) than for air and aluminum (5.0 < CNR < 32.8). Noise values ranged between 35 and 419. The uniformity index was between 3.3% and 11.9%. Full width at half maximum (FWHM) measurements varied between 0.43 mm and 1.07 mm. The increase of mean voxel values surrounding metal objects ranged between 6.7% and 43.0%. Results from preliminary analyses of the prototype quality control phantom showed its potential for routine quality assurance on CBCT. Large differences in image quality performance were seen between CBCT devices. Based on the initial evaluations, the phantom can be optimized and validated