98 research outputs found

    Effects of candesartan cilexetil on carotid remodeling in hypertensive diabetic patients: the MITEC study

    Get PDF
    In hypertension and diabetes, early structural changes of the arterial wall precede or support atherosclerosis. There is evidence that some antihypertensive drugs exert an antiathero-sclerotic effect. Over 36 months, we investigated the effect of candesartan cilexetil (CC) on the common carotid intima-media thickness (IMT) vs amlodipine besylate (AML) in patients with type 2 diabetes and mild to moderate essential hypertension. After a 4-week wash-out period, 209 patients were randomized to either CC 8 mg or AML 5 mg once daily for a minimum of 1 month, after which, if BP was not normalized, the dosage was doubled, followed by the addition of hydrochlorothiazide 12.5 mg if necessary. No significant differences were observed between the two groups for change in IMT at M12 (−0.001 vs −0.027 mm/year for CC and AML respectively, p = 0.425), at M24 (−0.033 vs −0.019 mm per year respectively, p = 0.442), and at the last visit (−0.016 vs −0.039 mm per year respectively, p = 0.549). Within the group, comparisons did not show a significant difference in changes in IMT from baseline to the three visits. At the last visit, IMT regression was observed in 52.2% of patients receiving CC and in 51.3% of those receiving AML (p = 0.908). The augmentation in carotid lumen diameter from baseline was statistically greater in the AML group at the last visit (p = 0.034). BP variations during the study were similar in the two groups. The results of this study show that CC and AML treatments may alter identically the natural progression of carotid IMT in hypertensive type 2 diabetic patients

    Tolerability of the Oscar 2 ambulatory blood pressure monitor among research participants: a cross-sectional repeated measures study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Ambulatory blood pressure monitoring (ABPM) is increasingly used to measure blood pressure (BP) in research studies. We examined ease of use, comfort, degree of disturbance, reported adverse effects, factors associated with poor tolerability, and association of poor tolerability with data acquisition of 24-hour ABPM using the Oscar 2 monitor in the research setting.</p> <p>Methods</p> <p>Sixty adults participating in a research study of people with a history of borderline clinic BP reported on their experience with ABPM on two occasions one week apart. Poor tolerability was operationalized as an overall score at or above the 75th percentile using responses to questions adapted from a previously developed questionnaire. In addition to descriptive statistics (means for responses to Likert-scaled "0 to 10" questions and proportions for Yes/No questions), we examined reproducibility of poor tolerability as well as associations with poor tolerability and whether poor tolerability was associated with removal of the monitor or inadequate number of BP measurements.</p> <p>Results</p> <p>The mean ambulatory BP of participants by an initial ABPM session was 148/87 mm Hg. After wearing the monitor the first time, the degree to which the monitor was felt to be cumbersome ranged from a mean of 3.0 to 3.8, depending on whether at work, home, driving, or other times. The most bother was interference with normal sleeping pattern (mean 4.2). Wearers found the monitor straightforward to use (mean 7.5). Nearly 67% reported that the monitor woke them after falling asleep, and 8.6% removed it at some point during the night. Reported adverse effects included pain (32%), skin irritation (37%), and bruising (7%). Those categorized as having poor tolerability (kappa = 0.5 between sessions, p = 0.0003) were more likely to report being in fair/poor health (75% vs 22%, p = 0.01) and have elevated 24-hour BP average (systolic: 28% vs 17%, p = 0.56; diastolic: 30% vs 17%, p = 0.37). They were also more likely to remove the monitor and have inadequate numbers of measurements.</p> <p>Conclusions</p> <p>The Oscar 2 ABPM device is straightforward to use but can interfere with sleep. Commonly reported adverse effects include pain, skin irritation, and bruising. Those who tolerate the monitor poorly are more likely to report being in fair or poor health and to remove it, particularly at night.</p

    Favorable patient acceptance of ambulatory blood pressure monitoring in a primary care setting in the United States: a cross-sectional survey

    Get PDF
    BACKGROUND: The use of ambulatory blood pressure monitoring (ABPM) in the diagnosis and management of hypertension in primary care settings in the United States is increasing. Insufficient information is available describing patients' experiences and acceptance of this technology in the United States, where medical insurance coverage of the procedure is often limited. The objective of this study was to describe patient satisfaction with ABPM performed in a primary care office in the United States, using modern ABPM technology. METHODS: Cross-sectional survey performed on consecutive patients referred to the ABPM service of the Family Care Center, University of Iowa Hospitals and Clinics, Iowa City, Iowa from January 2001 to July 2003. Measures of patient satisfaction and acceptance with the device, comfort, and overall session were assessed via a 9-question, Likert-scale response survey. RESULTS: Since its inception two and a half years ago, 245 total ABPM sessions have been conducted in 235 unique patients. Of the 235 eligible respondents, 177 returned completed surveys, yielding a 75% response rate. Three-fourths (75%) of patients believed that undergoing the test was worthwhile considering the time and monetary cost involved, while most (90%) reported they thought the information provided by the test would be helpful to their physician in making treatment decisions. Patients reporting that their physician had clearly explained the benefit of undergoing the testing were more likely to report that they thought the results of the test would be more helpful in making treatment decisions. Few patients (20%) found that wearing the monitor was uncomfortable. CONCLUSIONS: When clinically indicated, clinicians should not hesitate to order ABPM testing for fear of subjecting patients to an uncomfortable test, or an uncovered insurance benefit. When ordering ABPM, they should be sure to educate the patient about the potential benefits of undergoing the testing. Most patients believe the test will provide useful information in making treatment decisions, despite probable lack of insurance coverage, and appear willing to experience some discomfort for the overall gain of the results obtained from undergoing the session

    All that glisters is not gold: a comparison of electronic monitoring versus filled prescriptions – an observational study

    Get PDF
    BACKGROUND: Poor compliance with antihypertensive medication is assumed to be an important reason for unsatisfactory control of blood pressure. Poor compliance is difficult to detect. Each method of measuring compliance has its own strengths and weaknesses. The aim of the present study was to compare patient compliance with antihypertensive drugs as measured by two methods, electronic monitoring versus refill compliance. METHODS: 161 patients with a diagnosis of hypertension for at least a year prior to inclusion, and inadequate blood pressure control (systolic blood pressure ≥ 160 mmHg and/or diastolic blood pressure ≥ 95 mmHg) despite the use of antihypertensive drugs, were included. Patients' pharmacy records from 12 months prior to inclusion were obtained. Refill compliance was calculated as the number of days for which the pills were prescribed divided by the total number of days in this period. After inclusion compliance was measured with an electronic monitor that records time and date of each opening of the pillbox. Agreement between both compliance measures was calculated using Spearman's correlation coefficient and Cohen's kappa coefficient. RESULTS: There was very little agreement between the two measures. Whereas refill compliance showed a large range of values, compliance as measured by electronic monitoring was high in almost all patients with estimates between 90% and 100%. Cohen's kappa coefficient was 0.005. CONCLUSION: While electronic monitoring is often considered to be the gold standard for compliance measurements, our results suggest that a short-term electronic monitoring period with the patient being aware of electronic monitoring is probably insufficient to obtain valid compliance data. We conclude that there is a strong need for more studies that explore the effect of electronic monitoring on patient's compliance

    Twenty-four-hour intraocular pressure and ocular perfusion pressure characteristics in newly diagnosed patients with normal tension glaucoma

    Get PDF
    PurposeTo determine the mean 24-h intraocular pressure (IOP) and mean ocular perfusion pressure (MOPP) characteristics of newly diagnosed, previously untreated, Caucasian, normal tension glaucoma (NTG) patients and to identify relationships between these features and visual field (VF) loss at diagnosis.MethodsConsecutive newly diagnosed NTG patients underwent 24-h habitual IOP and blood pressure (BP) monitoring. Parameters from pooled measurements obtained in the sitting (0800-2200 hours) and supine (1200-0600 hours) positions were compared and associations were sought with VF mean deviation (MD) and pattern standard deviation (PSD).ResultsSixty-two Caucasian NTG patients (24 men and 38 women) successfully completed circadian IOP and BP monitoring. In habitual position, 8 subjects (12.9%) exhibited a diurnal acrophase, 42 subjects (67.7%) demonstrated a nocturnal acrophase, one subject (1.6%) showed a flat rhythm and 11 patients (17.7%) revealed a biphasic/polyphasic rhythm. Nighttime MOPP values (supine position) were significantly greater than diurnal values (sitting position); (P<0.001). No association could be demonstrated between glaucomatous damage, as indicated by VF parameters, and either mean habitual 24-h IOP (P=0.20 and P=0.12 for MD and PSD, respectively), or habitual 24-h MOPP (P=0.96 and 0.29, for MD and PSD, respectively).ConclusionsIn this cohort of Caucasian NTG patients, most patients exhibited a nocturnal IOP acrophase when evaluated in a habitual position. No association was found between 24-h IOP or MOPP and VF damage.Eye advance online publication, 29 July 2016; doi:10.1038/eye.2016.168
    corecore