1,294 research outputs found

    Characterization of mode 1 and mixed-mode failure of adhesive bonds between composite adherends

    Get PDF
    A combined experimental and analytical investigation of an adhesively bonded composite joint was conducted to characterize both the static and fatigue beyond growth mechanism under mode 1 and mixed-mode 1 and 2 loadings. Two bonded systems were studied: graphite/epoxy adherends bonded with EC 3445 and FM-300 adhesives. For each bonded system, two specimen types were tested: a double-cantilever-beam specimen for mode 1 loading and a cracked-lapshear specimen for mixed-mode 1 and 2 loading. In all specimens tested, failure occurred in the form of debond growth. Debonding always occurred in a cohesive manner with EC 3445 adhesive. The FM-300 adhesive debonded in a cohesive manner under mixed-mode 1 and 2 loading, but in a cohesive, adhesive, or combined cohesive and adhesive manner under mode 1 loading. Total strain-energy release rate appeared to be the driving parameter for debond growth under static and fatigue loadings

    Influence of interface ply orientation on fatigue damage of adhesively bonded composite joints

    Get PDF
    An experimental study of cracked-lap-shear specimens was conducted to determine the influence of adherend stacking sequence on debond initiation and damage growth in a composite-to-composite bonded joint. Specimens consisted of quasi-isotropic graphite/epoxy adherends bonded together with either FM-300 or EC 3445 adhesives. The stacking sequence of the adherends was varied such that 0 deg, 45 deg, or 90 deg plies were present at the adherend-adhesive interfaces. Fatigue damage initiated in the adhesive layer in those specimens with 0 deg nd 45 deg interface plies. Damage initiated in the form of ply cracking in the strap adherend for the specimens with 90 deg interface plies. The fatigue-damage growth was in the form of delamination within the composite adherends for specimens with the 90 deg and 45 deg plies next to the adhesive, while debonding in the adhesive resulted for the specimens with 0 deg plies next to the adhesive. Those joints with the 0 deg and 45 deg plies next to either adhesive has essentially the same fatigue-damage-initiation stress levels. These stress levels were 13 and 71 percent higher, respectively, than those for specimens with 90 deg plies next to the EC 3445 and FM-300 adhesives

    Cyclic debonding of adhesively bonded composites

    Get PDF
    The fatigue behavior of a simple composite to composite bonded joint was analyzed. The cracked lap shear specimen subjected to constant amplitude cyclic loading was studied. Two specimen geometries were tested for each bonded system: (1) a strap adherend of 16 plies bonded to a lap adherend of 8 plies; and (2) a strap adherend of 8 plies bonded to a lap adherend of 16 plies. In all specimens the fatigue failure was in the form of cyclic debonding with some 0 deg fiber pull off from the strap adherend. The debond always grew in the region of adhesive that had the highest mode (peel) loading and that region was close to the adhesive strap interface

    Application of advanced technologies to small, short-haul transport aircraft (STAT)

    Get PDF
    The benefits of selected advanced technologies for 19 and 30 passenger, short-haul aircraft were identified. Advanced technologies were investigated in four areas: aerodynamics, propulsion, structures, and ride quality. Configuration sensitivity studies were conducted to show design tradeoffs associated with passenger capacity, cabin comfort level, and design field length

    Development of a nuclear technique for monitoring water levels in pressurized vehicles

    Get PDF
    A new technique for monitoring water levels in pressurized stainless steel cylinders was developed. It is based on differences in attenuation coefficients of water and air for Cs137 (662 keV) gamma rays. Experimentally observed gamma ray counting rates with and without water in model reservoir cylinder were compared with corresponding calculated values for two different gamma ray detection theshold energies. Calculated values include the effects of multiple scattering and attendant gamma ray energy reductions. The agreement between the measured and calculated values is reasonably good. Computer programs for calculating angular and spectral distributions of scattered radition in various media are included

    Clemson veterans project

    Get PDF
    The Clemson Veterans Project exist to honor the stories of combat veterans from conflicts throughout our country\u27s history and do so in a professional manner expected from a university with such a rich military heritage. The project collected over 70 interviews in HD video. All videos have been made public on Youtube. The project was started to assist the Library of Congress with its own Veterans History Project. Before interviewing each student must take an exam on the digital file preparation process, interview courtesy, and then conduct a practice interview where they behave exactly as if it was a real interview. The videos are put onto DVDs along with accompanying documentation and then shipped in bulk. Going above the requirements for the LoC, each shipment contains a flash drive with every video and document in a digital format. Special interviews are selected for post-production including a custom made introduction

    Cohomology of bundles on homological Hopf manifold

    Full text link
    We discuss the properties of complex manifolds having rational homology of S1×S2n1S^1 \times S^{2n-1} including those constructed by Hopf, Kodaira and Brieskorn-van de Ven. We extend certain previously known vanishing properties of cohomology of bundles on such manifolds.As an application we consider degeneration of Hodge-deRham spectral sequence in this non Kahler setting.Comment: To appear in Proceedings of 2007 conference on Several complex variables and Complex Geometry. Xiamen. Chin

    PANIC: the new panoramic NIR camera for Calar Alto

    Full text link
    PANIC is a wide-field NIR camera, which is currently under development for the Calar Alto observatory (CAHA) in Spain. It uses a mosaic of four Hawaii-2RG detectors and covers the spectral range from 0.8-2.5 micron(z to K-band). The field-of-view is 30x30 arcmin. This instrument can be used at the 2.2m telescope (0.45arcsec/pixel, 0.5x0.5 degree FOV) and at the 3.5m telescope (0.23arcsec/pixel, 0.25x0.25 degree FOV). The operating temperature is about 77K, achieved by liquid Nitrogen cooling. The cryogenic optics has three flat folding mirrors with diameters up to 282 mm and nine lenses with diameters between 130 mm and 255 mm. A compact filter unit can carry up to 19 filters distributed over four filter wheels. Narrow band (1%) filters can be used. The instrument has a diameter of 1.1 m and it is about 1 m long. The weight limit of 400 kg at the 2.2m telescope requires a light-weight cryostat design. The aluminium vacuum vessel and radiation shield have wall thicknesses of only 6 mm and 3 mm respectively.Comment: This paper has been presented in the SPIE of Astronomical Telescopes and Instrumentation 2008 in Marseille (France

    Observations of the longitudinal spread of solar energetic particle events in solar cycle 24

    Get PDF
    With the twin STEREO spacecraft, significantly separated from L1-based satellites such as ACE, simultaneous multi-point measurements of solar energetic particle (SEP) events can be made for H-Fe ions from a few hundred keV/nuc to over 100 MeV/nuc and for electrons from tens to hundreds of keV. These observations allow studies of the longitudinal characteristics of SEP events to advance beyond statistical analysis of single point measurements. Although there have been few large SEP events thus far in cycle 24, there have been a number of smaller events that have been detected by more than one spacecraft. The composition of these SEP events, as indicated by the H/He and Fe/O abundance ratios, shows a dependence on longitudinal distance from the solar source in some events, at times with ratios varying by an order of magnitude. However, these variations are not organized by either the speed or width of the associated coronal mass ejections

    Outcome of revision anterior cruciate ligament reconstruction: a systematic review

    Get PDF
    BACKGROUND: Revision anterior cruciate ligament (ACL) reconstruction is believed to have an inferior outcome compared with primary ACL reconstruction. The available literature on the outcome of revision ACL reconstruction is sparse compared with that for primary reconstruction. The purpose of this systematic review was to test the hypothesis that the outcome of revision ACL reconstruction compares unfavorably with the historical outcome of primary ACL reconstruction. METHODS: A systematic review of studies evaluating the outcome of revision ACL reconstructions with a minimum of two years of follow-up was performed. Pooled data were collected when appropriate and a mixed-effect-model meta-analysis was performed for important outcome measures that were reported in several studies (objective graft failure, Lysholm score, International Knee Documentation Committee [IKDC] subjective score, and IKDC objective score). Objective failure was defined as repeat revision, a side-to-side difference of >5 mm measured with use of a KT1000 arthrometer, or a pivot-shift grade of 2+ or 3+. RESULTS: Twenty-one studies were included, and 863 of the 1004 patients in these studies had a minimum of two years of follow-up and were analyzed. The pooled mean age of the patients at the time of the revision procedure was 30.6 years, and 66% were male. Objective failure occurred in 13.7% ± 2.7% of the patients (95% confidence interval, 8.0% to 19.4%). The mean Lysholm score in 491 patients was 82.1 ± 3.3 (95% confidence interval, 74.6 to 89.5) according to a mixed-model meta-analysis. The mean IKDC subjective score in 202 patients was 74.8 ± 4.4 (95% confidence interval, 62.5 to 87.0). CONCLUSIONS: Revision ACL reconstruction resulted in a worse outcome compared with primary ACL reconstruction. Patient-reported outcome scores were inferior to previously published results of primary ACL reconstruction, but these differences may not be clinically important. A dramatically elevated failure rate was noted after revision ACL reconstruction; this rate was nearly three to four times the failure rate in prospective series of primary ACL reconstructions
    corecore