1,511 research outputs found
Data Streams from the Low Frequency Instrument On-Board the Planck Satellite: Statistical Analysis and Compression Efficiency
The expected data rate produced by the Low Frequency Instrument (LFI) planned
to fly on the ESA Planck mission in 2007, is over a factor 8 larger than the
bandwidth allowed by the spacecraft transmission system to download the LFI
data. We discuss the application of lossless compression to Planck/LFI data
streams in order to reduce the overall data flow. We perform both theoretical
analysis and experimental tests using realistically simulated data streams in
order to fix the statistical properties of the signal and the maximal
compression rate allowed by several lossless compression algorithms. We studied
the influence of signal composition and of acquisition parameters on the
compression rate Cr and develop a semiempirical formalism to account for it.
The best performing compressor tested up to now is the arithmetic compression
of order 1, designed for optimizing the compression of white noise like
signals, which allows an overall compression rate = 2.65 +/- 0.02. We find
that such result is not improved by other lossless compressors, being the
signal almost white noise dominated. Lossless compression algorithms alone will
not solve the bandwidth problem but needs to be combined with other techniques.Comment: May 3, 2000 release, 61 pages, 6 figures coded as eps, 9 tables (4
included as eps), LaTeX 2.09 + assms4.sty, style file included, submitted for
the pubblication on PASP May 3, 200
Trade-off between angular resolution and straylight contamination in CMB anisotropy experiments. II. Straylight evaluation
Satellite CMB anisotropy missions and new generation of balloon-borne and
ground experiments, make use of complex multi-frequency instruments at the
focus of a meter class telescope. Between 70 GHz and 300 GHz, where foreground
contamination is minimum, it is extremely important to reach the best trade-off
between the improvement of the angular resolution and the minimization of the
straylight contamination mainly due to the Galactic emission. We focus here, as
a working case, on the 30 and 100 GHz channels of the Planck Low Frequency
Instrument (LFI). We evaluate the GSC introduced by the most relevant Galactic
foreground components for a reference set of optical configurations. We show
that it is possible to improve the angular resolution of 5-7% by keeping the
overall GSC below the level of few microKelvin. A comparison between the level
of straylight introduced by the different Galactic components for different
beam regions is presented. Simple approximate relations giving the rms and
peak-to-peak levels of the GSC are provided. We compare the results obtained at
100 GHz with those at 30 GHz, where GSC is more critical. Finally, we compare
the results based on Galactic foreground templates derived from radio and IR
surveys with those based on WMAP maps including CMB and extragalactic source
fluctuations.Comment: Submitted to A&A. Quality of the figures was degraded for
size-related reason
CMB signal in WMAP 3yr data with FastICA
We present an application of the fast Independent Component Analysis
(FastICA) to the WMAP 3yr data with the goal of extracting the CMB signal. We
evaluate the confidence of our results by means of Monte Carlo simulations
including CMB, foreground contaminations and instrumental noise specific of
each WMAP frequency band. We perform a complete analysis involving all or a
subset of the WMAP channels in order to select the optimal combination for CMB
extraction, using the frequency scaling of the reconstructed component as a
figure of merit. We found that the combination KQVW provides the best CMB
frequency scaling, indicating that the low frequency foreground contamination
in Q, V and W bands is better traced by the emission in the K band. The CMB
angular power spectrum is recovered up to the degree scale, it is consistent
within errors for all WMAP channel combination considered, and in close
agreement with the WMAP 3yr results. We perform a statistical analysis of the
recovered CMB pattern, and confirm the sky asymmetry reported in several
previous works with independent techniques.Comment: 10 pages, 7 figures, submitted to MNRA
Full Sky Study of Diffuse Galactic Emission at Decimeter Wavelengths
A detailed knowledge of the Galactic radio continuum is of high interest for
studies of the dynamics and structure of the Galaxy as well as for the problem
of foreground removal in Cosmic Microwave Background measurements. In this work
we present a full-sky study of the diffuse Galactic emission at frequencies of
few GHz, where synchrotron radiation is by far the dominant component. We
perform a detailed combined analysis of the extended surveys at 408, 1420 and
2326 MHz (by Haslam et al. 1982, Reich 1982, Reich & Reich, 1986 and Jonas et
al. 1998, respectively). Using the technique applied by Schlegel et al. (1998)
to the IRAS data, we produce destriped versions of the three maps. This allows
us to construct a nearly-full-sky map of the spectral index and of the
normalization factor with sub-degree angular resolution. The resulting
distribution of the spectral indices has an average of beta = 2.695 and
dispersion sigma_{beta} = 0.120. This is representative for the Galactic
diffuse synchrotron emission, with only minor effects from free-free emission
and point sources.Comment: 10 pages, 16 jpeg figures, accepted to Astronomy & Astrophysics,
Comments and figure adde
Characterization of high impedance connecting links for Bolometric detectors
Abstract High impedance connecting links and cables are tested at low frequency in terms of their parasitic impedance to ground and to neighboring connecting links. These parameters must be well characterized with detectors operated at low temperature, especially when the very front-end is at room temperature, which results in a long link. This is the case of the LUCIFER experiment, an array of crystals where every event of interest produces two signals, one composed of phonons, the other of photons. The parasitic impedance is usually considered to be the parallel combination of a resistance and a capacitance. We characterized both and found that from the static measurements the capacitance of the cable resulted much larger. On the basis of this result we optimized the measurement set-up and developed a model to account for this behavior
Concerning some integrals of the generalized exponential-integral function
AbstractThis paper deals with some integrals involving the generalized exponential integral, Eν(x), which are of interest for applications. New relations have been derived by generalizing known expressions valid for ν = n integer. Numerical results are also given, which extend existing tables to the entire real domain
An ultra fast, low power readout chain for single photon sensitivity with multi-anode photomultiplier tubes for the RICH upgrade at LHCb
Abstract An upgrade proposal for the LHCb RICH detectors at the Large Hadron Collider at CERN is being developed at the INFN section of Milano Bicocca, based on multi-anode photomultiplier tubes. The application requires the fast readout of Cherenkov rings of photons, with single photon sensitivity, at an event rate up to 40 MHz. The proposed readout chain is tailored for the R7600 multi-anode photomultiplier tubes from Hamamatsu, which proved to fit the single photon sensitivity requirement. The readout electronics for each pixel will be composed of an analog pulse shaper, a binary discriminator and additional digital circuitry to count the pulses. A prototype of the analog shaper was built with commercial discrete transistors in Silicon–Germanium (SiGe) Heterojunction technology. The tradeoff between response speed and power dissipation was investigated; and power as low as a few mW per channel could be achieved with response times of the order of one nanosecond. Furthermore, noise and jitter were evaluated, showing very good performances of the prototype
Characterization of the Hamamatsu R11265-103-M64 multi-anode photomultiplier tube
The aim of this paper is to fully characterize the new multi-anode
photomultiplier tube R11265-103-M64, produced by Hamamatsu. Its high effective
active area (77%), its pixel size, the low dark signal rate and the capability
to detect single photon signals make this tube suitable for an application in
high energy physics, such as for RICH detectors. Four tubes and two different
bias voltage dividers have been tested. The results of a standard
characterization of the gain and the anode uniformity, the dark signal rate,
the cross-talk and the device behaviour as a function of temperature have been
studied. The behaviour of the tube is studied in a longitudinal magnetic field
up to 100 Gauss. Shields made of a high permeability material are also
investigated. The deterioration of the device performance due to long time
operation at intense light exposure is studied. A quantitative analysis of the
variation of the gain and the dark signals rate due to the aging is described.Comment: 22 page
Electrical characterization of the low background Cu-PEN links of the CUORE experiment
Abstract In the CUORE experiment, under construction at LNGS (Gran Sasso National Laboratory), Cu-PEN tapes are the first part of the connecting links between the detector and the front-end electronics. Deep electrical characterization on each tape is to be performed, to ascertain that they comply with the requirements of the experiment. The characterization method is presented here. The first part is based on the time domain reflectometry (TDR) technique, to check the integrity of the electrical link while touching only one end of the tape, to avoid any possible damage to the bonding pads. The TDR measurement allows to locate possible defects on the tapes with a resolution of about 5 cm. The second part of the characterization is focused on the parasitic impedance between neighboring links. For this characterization, a commercial electrometer is used; custom boards with remote control capability were built, in order to be able to check the links in vacuum and reach sensitivities on the parasitic conductance of the order of 1 pA/V
- …