146 research outputs found

    New occurrence of B chromosomes in Partamonahelleri (Friese, 1900) (Hymenoptera, Meliponini)

    Get PDF
    Cytogenetic analyses of the stingless bee Partamona helleri collected in the state of Bahia, Northeast Brazil revealed the chromosome numbers n = 18 in the haploid males and 2n = 35 in the diploid females. All karyotypes displayed one large acrocentric B chromosome, which differs from the minute B chromosomes previously described in the populations from southeastern Brazil. Giemsa staining, C-banding and DAPI/CMA3 fluorochrome staining also revealed a remarkable interpopulational divergence regarding both the regular karyotype and the B chromosomes. The B chromosomes found in the samples from Jequié, Bahia, were entirely heterochromatic, while those found in Cravolândia, Bahia, displayed a euchromatic portion at the telomeric end of the long arm. CMA 3 labeling sites varied from seven to eight between the two localities in Bahia, due to the presence of an extra GC-rich block in the karyotype of the samples from Jequié. This is the first report of a large B chromosome in P. helleri and reveals the occurrence of a geographic differentiation within this species

    Thermoelectric and Structural Properties of Sputtered AZO Thin Films with Varying Al Doping Ratios

    Get PDF
    Nanomaterials can be game-changers in the arena of sustainable energy production because they may enable highly efficient thermoelectric energy conversion and harvesting. For this purpose, doped thin film oxides have been proven to be promising systems for achieving high thermoelectric performances. In this work, the design, realization, and experimental investigation of the thermoelectric properties exhibited by a set of five Al:ZnO thin films with thicknesses of 300 nm and Al doping levels ranging from 2 to 8 at.% are described. Using a multi-technique approach, the main structural and morphological features of the grown thin films are addressed, as well as the electrical and thermoelectrical transport properties. The results show that the samples exhibited a Seebeck coefficient absolute value in the range of 22-33 mu V/K, assuming their maximum doping level was 8 at.%, while the samples' resistivity was decreased below 2 x 10(-3) Ohm center dot cm with a doping level of 3 at.%. The findings shine light on the perspectives of the applications of the metal ZnO thin film technology for thermoelectrics

    Adaptive Filtering Enhances Information Transmission in Visual Cortex

    Full text link
    Sensory neuroscience seeks to understand how the brain encodes natural environments. However, neural coding has largely been studied using simplified stimuli. In order to assess whether the brain's coding strategy depend on the stimulus ensemble, we apply a new information-theoretic method that allows unbiased calculation of neural filters (receptive fields) from responses to natural scenes or other complex signals with strong multipoint correlations. In the cat primary visual cortex we compare responses to natural inputs with those to noise inputs matched for luminance and contrast. We find that neural filters adaptively change with the input ensemble so as to increase the information carried by the neural response about the filtered stimulus. Adaptation affects the spatial frequency composition of the filter, enhancing sensitivity to under-represented frequencies in agreement with optimal encoding arguments. Adaptation occurs over 40 s to many minutes, longer than most previously reported forms of adaptation.Comment: 20 pages, 11 figures, includes supplementary informatio

    The BINGO Project: III. Optical design and optimization of the focal plane

    Get PDF
    Context. The Baryon Acoustic Oscillations from Integrated Neutral Gas Observations (BINGO) telescope was designed to measure the fluctuations of the 21 cm radiation arising from the hyperfine transition of neutral hydrogen. It is also aimed at measuring the baryon acoustic oscillations (BAO) from such fluctuations, thereby serving as a pathfinder to future, deeper intensity mapping surveys. The requirements for the Phase 1 of the projects consider a large reflector system (two 40 m-class dishes in a crossed-Dragone configuration) illuminating a focal plane with 28 horns to measure the sky, with two circular polarizations in a drift scan mode to produce measurements of the radiation in intensity (I) as well as the circular (V) polarization. Aims. In this paper, we present the optical design for the instrument. We describe the optical arrangement of the horns in the focal plane to produce a homogeneous and well-sampled map after the end of Phase 1, as well as the intensity and polarization properties of the beams. Our analysis provides an optimal model for the location of the horns in the focal plane, producing a homogeneous and Nyquist-sampled map after the nominal survey time. Methods. We used the GRASP package to model the focal plane arrangement and performed several optimization tasks to arrive at the current configuration, including an estimation of the sidelobes corresponding to the diffraction patterns of the two mirrors. The final model for the focal plane was defined through a combination of neural network and other direct optimization methods. Results. We arrived at an optimal configuration for the optical system that includes the focal plane positioning and the beam behavior of the instrument. We present an estimate of the expected sidelobes both for intensity and polarization, as well as the effect of band averaging on the final sidelobes, as well as an estimation of the cross-polarization leakage for the final configuration. Conclusions. We conclude that the chosen optical design meets the requirements for the project in terms of polarization purity and area coverage as well as a homogeneity of coverage so that BINGO can perform a successful BAO experiment. We further conclude that the requirements on the placement and rms error on the mirrors are also achievable so that a successful experiment can be conducted

    Design choices made by target users for a pay-for-performance program in primary care: an action research approach

    Get PDF
    Contains fulltext : 110832.pdf (publisher's version ) (Open Access)BACKGROUND: International interest in pay-for-performance (P4P) initiatives to improve quality of health care is growing. Current programs vary in the methods of performance measurement, appraisal and reimbursement. One may assume that involvement of health care professionals in the goal setting and methods of quality measurement and subsequent payment schemes may enhance their commitment to and motivation for P4P programs and therefore the impact of these programs. We developed a P4P program in which the target users were involved in decisions about the P4P methods. METHODS: For the development of the P4P program a framework was used which distinguished three main components: performance measurement, appraisal and reimbursement. Based on this framework design choices were discussed in two panels of target users using an adapted Delphi procedure. The target users were 65 general practices and two health insurance companies in the South of the Netherlands. RESULTS: Performance measurement was linked to the Dutch accreditation program based on three domains (clinical care, practice management and patient experience). The general practice was chosen as unit of assessment. Relative standards were set at the 25th percentile of group performance. The incentive for clinical care was set twice as high as the one for practice management and patient experience. Quality scores were to be calculated separately for all three domains, and for both the quality level and the improvement of performance. The incentive for quality level was set thrice as high as the one for the improvement of performance. For reimbursement, quality scores were divided into seven levels. A practice with a quality score in the lowest group was not supposed to receive a bonus. The additional payment grew proportionally for each extra group. The bonus aimed at was on average 5% to 10% of the practice income. CONCLUSIONS: Designing a P4P program for primary care with involvement of the target users gave us an insight into their motives, which can help others who need to discuss similar programs. The resulting program is in line with target users' views and assessments of relevance and applicability. This may enhance their commitment to the program as was indicated by the growing number of voluntary participants after a successfully performed field test during the procedure. The elements of our framework can be very helpful for others who are developing or evaluating a P4P program

    Left and right ventricle assessment with Cardiac CT: validation study vs. Cardiac MR

    Get PDF
    Objectives To compare Magnetic Resonance (MR) and Computed Tomography (CT) for the assessment of left (LV) and right (RV) ventricular functional parameters. Methods Seventy nine patients underwent both Cardiac CT and Cardiac MR. Images were acquired using short axis (SAX) reconstructions for CT and 2D cine b-SSFP (balanced- steady state free precession) SAX sequence for MR, and evaluated using dedicated software. Results CT and MR images showed good agreement: LV EF (Ejection Fraction) (52±14% for CT vs. 52±14% for MR; r0 0.73; p>0.05); RV EF (47±12% for CT vs. 47±12% for MR; r00.74; p>0.05); LV EDV (End Diastolic Volume) (74± 21 ml/m 2 for CT vs. 76±25 ml/m 2 for MR; r00.59; p>0.05); RV EDV (84±25 ml/m 2 for CT vs. 80±23 ml/m 2 for MR; r0 0.58; p>0.05); LV ESV (End Systolic Volume)(37±19 ml/m 2 for CT vs. 38±23 ml/m 2 for MR; r00.76; p>0.05); RV ESV (46±21 ml/m 2 for CT vs. 43±18 ml/m 2 for MR; r00.70; p>0.05). Intra- and inter-observer variability were good, and the performance of CT was maintained for different EF subgroups. Conclusions Cardiac CT provides accurate and reproducible LVand RV volume parameters compared with MR, and can be considered as a reliable alternative for patients who are not suitable to undergo MR. Key Points • Cardiac-CT is able to provide Left and Right Ventricular function. • Cardiac-CT is accurate as MR for LV and RV volume assessment. • Cardiac-CT can provide accurate evaluation of coronary arteries and LV and RV function

    The BINGO project: I. Baryon acoustic oscillations from integrated neutral gas observations

    Get PDF
    Context. Observations of the redshifted 21-cm line of neutral hydrogen (HI) are a new and powerful window of observation that offers us the possibility to map the spatial distribution of cosmic HI and learn about cosmology. Baryon Acoustic Oscillations from Integrated Neutral Gas Observations (BINGO) is a new unique radio telescope designed to be one of the first to probe baryon acoustic oscillations (BAO) at radio frequencies. Aims. BINGO has two science goals: cosmology and astrophysics. Cosmology is the main science goal and the driver for BINGO's design and strategy. The key of BINGO is to detect the low redshift BAO to put strong constraints on the dark sector models and test the ICDM (cold dark matter) model. Given the versatility of the BINGO telescope, a secondary goal is astrophysics, where BINGO can help discover and study fast radio bursts (FRB) and other transients, as well as study Galactic and extragalactic science. In this paper, we introduce the latest progress of the BINGO project, its science goals, describing the scientific potential of the project for each goal and the new developments obtained by the collaboration. Methods. BINGO is a single dish transit telescope that will measure the BAO at low-z by making a 3D map of the HI distribution through the technique of intensity mapping over a large area of the sky. In order to achieve the project's goals, a science strategy and a specific pipeline for cleaning and analyzing the produced maps and mock maps was developed by the BINGO team, which we generally summarize here. Results. We introduce the BINGO project and its science goals and give a general summary of recent developments in construction, science potential, and pipeline development obtained by the BINGO Collaboration in the past few years. We show that BINGO will be able to obtain competitive constraints for the dark sector. It also has the potential to discover several FRBs in the southern hemisphere. The capacity of BINGO in obtaining information from 21-cm is also tested in the pipeline introduced here. Following these developments, the construction and observational strategies of BINGO have been defined. Conclusions. There is still no measurement of the BAO in radio, and studying cosmology in this new window of observations is one of the most promising advances in the field. The BINGO project is a radio telescope that has the goal to be one of the first to perform this measurement and it is currently being built in the northeast of Brazil. This paper is the first of a series of papers that describe in detail each part of the development of the BINGO project

    Influence of convolution filtering on coronary plaque attenuation values: observations in an ex vivo model of multislice computed tomography coronary angiography

    Get PDF
    Attenuation variability (measured in Hounsfield Units, HU) of human coronary plaques using multislice computed tomography (MSCT) was evaluated in an ex vivo model with increasing convolution kernels. MSCT was performed in seven ex vivo left coronary arteries sunk into oil followingthe instillation of saline (1/∞) and a 1/50 solution of contrast material (400 mgI/ml iomeprol). Scan parameters were: slices/collimation, 16/0.75 mm; rotation time, 375 ms. Four convolution kernels were used: b30f-smooth, b36f-medium smooth, b46f-medium and b60f-sharp. An experienced radiologist scored for the presence of plaques and measured the attenuation in lumen, calcified and noncalcified plaques and the surrounding oil. The results were compared by the ANOVA test and correlated with Pearson’s test. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. The mean attenuation values were significantly different between the four filters (p < 0.0001) in each structure with both solutions. After clustering for the filter, all of the noncalcified plaque values (20.8 ± 39.1, 14.2 ± 35.8, 14.0 ± 32.0, 3.2 ± 32.4 HU with saline; 74.7 ± 66.6, 68.2 ± 63.3, 66.3 ± 66.5, 48.5 ± 60.0 HU in contrast solution) were significantly different, with the exception of the pair b36f–b46f, for which a moderate-high correlation was generally found. Improved SNRs and CNRs were achieved by b30f and b46f. The use of different convolution filters significantly modifief the attenuation values, while sharper filtering increased the calcified plaque attenuation and reduced the noncalcified plaque attenuation
    corecore