6,483 research outputs found

    Cost-benefit analysis for commissioning decisions in GEO600

    Get PDF
    Gravitational wave interferometers are complex instruments, requiring years of commissioning to achieve the required sensitivities for the detection of gravitational waves, of order 10^-21 in dimensionless detector strain, in the tens of Hz to several kHz frequency band. Investigations carried out by the GEO600 detector characterisation group have shown that detector characterisation techniques are useful when planning for commissioning work. At the time of writing, GEO600 is the only large scale laser interferometer currently in operation running with a high duty factor, 70%, limited chiefly by the time spent commissioning the detector. The number of observable gravitational wave sources scales as the product of the volume of space to which the detector is sensitive and the observation time, so the goal of commissioning is to improve the detector sensitivity with the least possible detector down time. We demonstrate a method for increasing the number of sources observable by such a detector, by assessing the severity of non-astrophysical noise contaminations to efficiently guide commissioning. This method will be particularly useful in the early stages and during the initial science runs of the aLIGO and adVirgo detectors, as they are brought up to design performance.Comment: 17 pages, 17 figures, 2 table

    Methanol Masers as Tracers of Circumstellar Disks

    Get PDF
    We show that in many methanol maser sources the masers are located in lines, with a velocity gradient along them which suggests that the masers are situated in edge-on circumstellar, or protoplanetary, disks. We present VLBI observations of the methanol maser source G309.92+0.48, in the 12.2 GHz transition, which confirm previous observations that the masers in this source lie along a line. We show that such sources are not only linear in space but, in many cases, also have a linear velocity gradient. We then model these and other data in both the 6.7 GHz and the 12.2 GHz transition from a number of star formation regions, and show that the observed spatial and velocity distribution of methanol masers, and the derived Keplerian masses, are consistent with a circumstellar disk rotating around an OB star. We consider this and other hypotheses, and conclude that about half of these methanol masers are probably located in edge-on circumstellar disks around young stars. This is of particular significance for studies of circumstellar disks because of the detailed velocity information available from the masers.Comment: 38 pages, 13 figures accepted by Ap

    GEO 600 and the GEO-HF upgrade program: successes and challenges

    Get PDF
    The German-British laser-interferometric gravitational wave detector GEO 600 is in its 14th year of operation since its first lock in 2001. After GEO 600 participated in science runs with other first-generation detectors, a program known as GEO-HF began in 2009. The goal was to improve the detector sensitivity at high frequencies, around 1 kHz and above, with technologically advanced yet minimally invasive upgrades. Simultaneously, the detector would record science quality data in between commissioning activities. As of early 2014, all of the planned upgrades have been carried out and sensitivity improvements of up to a factor of four at the high-frequency end of the observation band have been achieved. Besides science data collection, an experimental program is ongoing with the goal to further improve the sensitivity and evaluate future detector technologies. We summarize the results of the GEO-HF program to date and discuss its successes and challenges

    Systematic review and meta-analysis of temozolomide in animal models of glioma:was clinical efficacy predicted?

    Get PDF
    Background:Malignant glioma is an aggressive tumour commonly associated with a dismal outcome despite optimal surgical and radio-chemotherapy. Since 2005 temozolomide has been established as first-line chemotherapy. We investigate the role of in vivo glioma models in predicting clinical efficacy.Methods:We searched three online databases to systematically identify publications testing temozolomide in animal models of glioma. Median survival and number of animals treated were extracted and quality was assessed using a 12-point scale; random effects meta-analysis was used to estimate efficacy. We analysed the impact of study design and quality and looked for evidence of publication bias.Results:We identified 60 publications using temozolomide in models of glioma, comprising 2443 animals. Temozolomide prolonged survival by a factor of 1.88 (95% CI 1.74-2.03) and reduced tumour volume by 50.4% (41.8-58.9) compared with untreated controls. Study design characteristics accounted for a significant proportion of between-study heterogeneity, and there was evidence of a significant publication bias.Conclusion:These data reflect those from clinical trials in that temozolomide improves survival and reduces tumour volume, even after accounting for publication bias. Experimental in vivo glioma studies of temozolomide differ from those of other glioma therapies in their consistent efficacy and successful translation into clinical medicine

    Will opposites attract? Similarities and differences in students' perceptions of the stereotype profiles of other health and social care professional groups

    Get PDF
    The extent to which health and social care (HSC) students hold stereotypical views of other HSC professional groups is of great potential importance to team working in health care. This paper explores students' perceptions of different HSC professional groups at the beginning of their university programmes. Findings are presented from an analysis of baseline data collected as part of the New Generation Project longitudinal cohort study which is assessing the impact of interprofessional education over time on a range of variables including stereotyping. Questionnaires were administered to a cohort of over 1200 students from 10 different HSC professional groups entering their first year of university. Stereotypes were measured using a tool adapted from Barnes et al. (2000) designed to elicit stereotype ratings on a range of nine characteristics. The findings confirm that students arrive at university with an established and consistent set of stereotypes about other health and social care professional groups. Stereotypical profiles were compiled for each professional group indicating the distinctive characteristics of the groups as well as the similarities and differences between groups. Midwives, social workers and nurses were rated most highly on interpersonal skills and on being a team player whilst doctors were rated most highly on academic ability. Doctors, midwives and social workers were perceived as having the strongest leadership role, whilst doctors were also rated most highly on decision making. All professions were rated highly on confidence and professional competence and, with the exception of social workers, on practical skills. A comparison of profiles for each professional group reveals that, for example, pharmacists and doctors were perceived as having very similar characteristics as were social workers, midwives and nurses. However, the profiles of nurses and doctors were perceived to be very different. The implications of these similarities and differences are discussed in terms of their potential impact on interprofessional interactions, role boundaries and team working

    Electro-optic time profile monitors for femtosecond electron bunches at the soft x-ray free-electron laser FLASH

    Get PDF
    Precise measurements of the temporal proïŹle of ultrashort electron bunches are of high interest for the optimization and operation of ultraviolet and x-ray free-electron lasers. The electro-optic (EO) technique has been applied for a single-shot direct visualization of the time proïŹle of individual electron bunches at FLASH. This paper presents a thorough description of the experimental setup and the results. An absolute calibration of the EO technique has been performed utilizing simultaneous measurements with a transverse-deïŹ‚ecting radio-frequency structure that transforms the longitudinal bunch charge distribution into a transverse streak. EO signals as short as 60 fs (rms) have been observed using a gallium-phosphide (GaP) crystal, which is a new record in the EO detection of single electron bunches and close to the physical limit imposed by the EO material properties. The data are in quantitative agreement with a numerical simulation of the EO detection process
    • 

    corecore