1,409 research outputs found

    Ionic liquids for energy, materials, and medicine.

    Full text link
    As highlighted by the recent ChemComm web themed issue on ionic liquids, this field continues to develop beyond the concept of interesting new solvents for application in the greening of the chemical industry. Here some current research trends in the field will be discussed which show that ionic liquids research is still aimed squarely at solving major societal issues by taking advantage of new fundamental understanding of the nature of these salts in their low temperature liquid state. This article discusses current research trends in applications of ionic liquids to energy, materials, and medicines to provide some insight into the directions, motivations, challenges, and successes being achieved with ionic liquids today

    Superhyperfine interactions in inhomogeneously broadened paramagnetic centers observed via a hole-burned free induction decay

    Get PDF
    Superhyperfine interactions in inhomogeneously broadened paramagnetic centers are observed using a single high-turn-angle microwave pulse. The free induction signal that follows the hole-burning pulse exhibits oscillations that are distinct from the oscillatory free induction decay observable in some inhomogeneously broadened systems. It contains frequencies characteristic of the superhyperfine splittings, together with a zero frequency component. Experimental examples of the effect in both orientationally disordered (powdered) and structurally disordered (glassy) systems are presented and compared with the conceptually similar Fourier transform electron paramagnetic resonance detected nuclear magnetic resonance experiment, together with numerical simulations. (C) 2003 American Institute of Physics

    Spin-crossover, mesomorphic and thermoelectrical properties of cobalt(II) complexes with alkylated N3-Schiff bases

    Get PDF
    Three new cobalt(ii) complexes, [Co(L12)2](BF4)2 (1), [Co(L14)2](BF4)2·H2O (2) and [Co(L16)2](BF4)2·H2O (3), where L12-16 are N3-Schiff bases appended with linear C12-16 carbon chains at the nitrogen atoms, were obtained in good yields by facile one-pot reactions. The single crystal X-ray structure of complex 1 shows a tetragonally compressed CoN6 coordination geometry. The melting temperatures of 1-3 were lower than 373 K, while their decomposition temperatures were above 473 K. All complexes have high-spin Co(ii) centres at 300 K and exhibit a columnar mesophase above 383 K. Complexes 1 and 3 showed normal thermal spin-crossover behaviour with weak hysteresis loops at about 320 K. Hence, these complexes showed uncoupled phase transitions (class iiia). The values for the Seebeck coefficient (Se) of the cobalt redox couples formed from 1 and 2 were 1.89 ± 0.02 mV K-1 and 1.92 ± 0.08 mV K-1, respectively, identifying them as potential thermoelectrochemical materials

    Outcome following surgery for colorectal cancer: analysis by hospital after adjustment for case-mix and deprivation

    Get PDF
    Outcome, adjusted for case-mix and deprivation, in 3200 patients undergoing resection for colorectal cancer in 11 hospitals in Central Scotland between 1991 and 1994 was studied. There were significant differences among individual hospitals in the proportion of elderly (P<0.001) and deprived (P<0.0001) patients, the mode (P=0.007) and stage (P<0.0001) at presentation, and the proportion of patients who underwent apparently curative resection (P<0.001). There were no significant differences in postoperative mortality. Cancer-specific survival at 5 years following apparently curative resection varied from 59 to 76%; cancer-specific survival at 2 years following palliative resection varied from 22 to 44%. The corresponding hazard ratios, adjusted for the above prognostic factors, for patients undergoing apparently curative resection varied among hospitals from 0.58 to 1.32; and the ratios for palliative resection varied from 0.73 to 1.26. This study demonstrates that, after adjustment for variations in case-mix and deprivation, significant differences in outcome among hospitals following resection for colorectal cancer persist

    Increased sensitivity to TRAIL-induced apoptosis occurs during the adenoma to carcinoma transition of colorectal carcinogenesis

    Get PDF
    The death ligand TRAIL (Apo2L) has potential for cancer therapy, since tumour cells are thought to be more sensitive than normal cells. We investigated whether sensitivity to TRAIL increases during the adenoma to carcinoma transition of colorectal carcinogenesis. Under the same culture conditions, we compared the extent of TRAIL-induced apoptosis in four premalignant adenoma and three carcinoma cell lines. Although TRAIL induced some apoptosis in adenoma cultures, the carcinoma cell lines were significantly more sensitive (P<0.001). This finding was recapitulated in an in vitro model of tumour progression in which conversion of the adenoma cell line AA/C1 to a tumorigenic phenotype was associated with increased TRAIL sensitivity (P<0.001). Increased TRAIL sensitivity during colorectal carcinogenesis has been previously attributed to changes in the balance between TRAIL receptors TRAIL-R1 and -R2 and ‘decoy' receptors TRAIL-R3 and -R4 during malignant progression. To address this, cell surface receptor expression was measured by flow cytometry. In summary, during colorectal carcinogenesis, there is a marked increase in sensitivity to TRAIL-induced apoptosis associated with progression from benign to malignant tumour that could be exploited for colon cancer therapy, but alterations in cell surface TRAIL receptor expression may not be the primary reason for this change

    Delivery of sTRAIL variants by MSCs in combination with cytotoxic drug treatment leads to p53-independent enhanced antitumor effects

    Get PDF
    Mesenchymal stem cells (MSCs) are able to infiltrate tumor tissues and thereby effectively deliver gene therapeutic payloads. Here, we engineered murine MSCs (mMSCs) to express a secreted form of the TNF-related apoptosis-inducing ligand (TRAIL), which is a potent inducer of apoptosis in tumor cells, and tested these MSCs, termed MSC.sTRAIL, in combination with conventional chemotherapeutic drug treatment in colon cancer models. When we pretreated human colorectal cancer HCT116 cells with low doses of 5-fluorouracil (5-FU) and added MSC.sTRAIL, we found significantly increased apoptosis as compared with single-agent treatment. Moreover, HCT116 xenografts, which were cotreated with 5-FU and systemically delivered MSC.sTRAIL, went into remission. Noteworthy, this effect was protein 53 (p53) independent and was mediated by TRAIL-receptor 2 (TRAIL-R2) upregulation, demonstrating the applicability of this approach in p53-defective tumors. Consequently, when we generated MSCs that secreted TRAIL-R2-specific variants of soluble TRAIL (sTRAIL), we found that such engineered MSCs, labeled MSC.sTRAIL DR5, had enhanced antitumor activity in combination with 5-FU when compared with MSC.sTRAIL. In contrast, TRAIL-resistant pancreatic carcinoma PancTu1 cells responded better to MSC.sTRAIL DR4 when the antiapoptotic protein XIAP (X-linked inhibitor of apoptosis protein) was silenced concomitantly. Taken together, our results demonstrate that TRAIL-receptor selective variants can potentially enhance the therapeutic efficacy of MSC-delivered TRAIL as part of individualized and tumor-specific combination treatments. © 2013 Macmillan Publishers Limited All rights reserved

    Validity of the international physical activity questionnaire and the Singapore prospective study program physical activity questionnaire in a multiethnic urban Asian population

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Physical activity patterns of a population remain mostly assessed by the questionnaires. However, few physical activity questionnaires have been validated in Asian populations. We previously utilized a combination of different questionnaires to assess leisure time, transportation, occupational and household physical activity in the Singapore Prospective Study Program (SP2). The International Physical Activity Questionnaire (IPAQ) has been developed for a similar purpose. In this study, we compared estimates from these two questionnaires with an objective measure of physical activity in a multi-ethnic Asian population.</p> <p>Methods</p> <p>Physical activity was measured in 152 Chinese, Malay and Asian Indian adults using an accelerometer over five consecutive days, including a weekend. Participants completed both the physical activity questionnaire in SP2 (SP2PAQ) and IPAQ long form. 43subjects underwent a second set of measurements on average 6 months later to assess reproducibility of the questionnaires and the accelerometer measurements. Spearman correlations were used to evaluate validity and reproducibility and correlations for validity were corrected for within-person variation of accelerometer measurements. Agreement between the questionnaires and the accelerometer measurements was also evaluated using Bland Altman plots.</p> <p>Results</p> <p>The corrected correlation with accelerometer estimates of energy expenditure from physical activity was better for the SP2PAQ (vigorous activity: r = 0.73; moderate activity: r = 0.27) than for the IPAQ (vigorous activity: r = 0.31; moderate activity: r = 0.15). For moderate activity, the corrected correlation between SP2PAQ and the accelerometer was higher for Chinese (r = 0.38) and Malays (r = 0.57) than for Indians (r = -0.09). Both questionnaires overestimated energy expenditure from physical activity to a greater extent at higher levels of physical activity than at lower levels of physical activity. The reproducibility for moderate activity (accelerometer: r = 0.68; IPAQ: r = 0.58; SP2PAQ: r = 0.55) and vigorous activity (accelerometer: 0.52; IPAQ: r = 0.38; SP2PAQ: r = 0.75) was moderate to high for all instruments.</p> <p>Conclusion</p> <p>The agreement between IPAQ and accelerometer measurements of energy expenditure from physical activity was poor in our Asian study population. The SP2PAQ showed good validity and reproducibility for vigorous activity, but performed less well for moderate activity particularly in Indians. Further effort is needed to develop questionnaires that better capture moderate activity in Asian populations.</p

    X-Ray Spectroscopy of Stars

    Full text link
    (abridged) Non-degenerate stars of essentially all spectral classes are soft X-ray sources. Low-mass stars on the cooler part of the main sequence and their pre-main sequence predecessors define the dominant stellar population in the galaxy by number. Their X-ray spectra are reminiscent, in the broadest sense, of X-ray spectra from the solar corona. X-ray emission from cool stars is indeed ascribed to magnetically trapped hot gas analogous to the solar coronal plasma. Coronal structure, its thermal stratification and geometric extent can be interpreted based on various spectral diagnostics. New features have been identified in pre-main sequence stars; some of these may be related to accretion shocks on the stellar surface, fluorescence on circumstellar disks due to X-ray irradiation, or shock heating in stellar outflows. Massive, hot stars clearly dominate the interaction with the galactic interstellar medium: they are the main sources of ionizing radiation, mechanical energy and chemical enrichment in galaxies. High-energy emission permits to probe some of the most important processes at work in these stars, and put constraints on their most peculiar feature: the stellar wind. Here, we review recent advances in our understanding of cool and hot stars through the study of X-ray spectra, in particular high-resolution spectra now available from XMM-Newton and Chandra. We address issues related to coronal structure, flares, the composition of coronal plasma, X-ray production in accretion streams and outflows, X-rays from single OB-type stars, massive binaries, magnetic hot objects and evolved WR stars.Comment: accepted for Astron. Astrophys. Rev., 98 journal pages, 30 figures (partly multiple); some corrections made after proof stag

    Effects of acute glucocorticoid blockade on metabolic dysfunction in patients with type 2 diabetes with and without fatty liver

    Get PDF
    To investigate the potential of therapies which reduce glucocorticoid action in patients with Type 2 diabetes we performed a randomized, double-blinded, placebo-controlled crossover study of acute glucocorticoid blockade, using the glucocorticoid receptor antagonist RU38486 (mifepristone) and cortisol biosynthesis inhibitor (metyrapone), in 14 men with Type 2 diabetes. Stable isotope dilution methodologies were used to measure the rates of appearance of glucose, glycerol, and free fatty acids (FFAs), including during a low-dose (10 mU·m −2·min−1) hyperinsulinemic clamp, and subgroup analysis was conducted in patients with high or low liver fat content measured by magnetic resonance spectroscopy (n = 7/group). Glucocorticoid blockade lowered fasting glucose and insulin levels and improved insulin sensitivity of FFA and glycerol turnover and hepatic glucose production. Among this population with Type 2 diabetes high liver fat was associated with hyperinsulinemia, higher fasting glucose levels, peripheral and hepatic insulin resistance, and impaired suppression of FFA oxidation and FFA and glycerol turnover during hyperinsulinemia. Glucocorticoid blockade had similar effects in those with and without high liver fat. Longer term treatments targeting glucocorticoid action may be useful in Type 2 diabetes with and without fatty liver

    Comparison of uniaxial and triaxial accelerometry in the assessment of physical activity among adolescents under free-living conditions: the HELENA study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Different types of devices are available and the choice about which to use depends on various factors: cost, physical characteristics, performance, and the validity and intra- and interinstrument reliability. Given the large number of studies that have used uniaxial or triaxial devices, it is of interest to know whether the different devices give similar information about PA levels and patterns. The aim of this study was to compare physical activity (PA) levels and patterns obtained simultaneously by triaxial accelerometry and uniaxial accelerometry in adolescents in free-living conditions.</p> <p>Methods</p> <p>Sixty-two participants, aged 13-16 years, were recruited in this ancillary study, which is a part of the Healthy Lifestyle in Europe by Nutrition in Adolescence (HELENA). All participants wore a uniaxial accelerometer (ActiGraph GT1M<sup>®</sup>, Pensacola, FL) and a triaxial accelerometer (RT3<sup>®</sup>, Stayhealthy, Monrovia, CA) simultaneously for 7 days. The patterns were calculated by converting accelerometer data output as a percentage of time spent at sedentary, light, moderate, and vigorous PA per day. Analysis of output data from the two accelerometers were assessed by two different tests: Equivalence Test and Bland & Altman method.</p> <p>Results</p> <p>The concordance correlation coefficient between the data from the triaxial accelerometer and uniaxial accelerometer at each intensity level was superior to 0.95. The ANOVA test showed a significant difference for the first three lower intensities while no significant difference was found for vigorous intensity. The difference between data obtained with the triaxial accelerometer and the uniaxial monitor never exceeded 2.1% and decreased as PA level increased. The Bland & Altman method showed good agreement between data obtained between the both accelerometers (<it>p </it>< 0.05).</p> <p>Conclusions</p> <p>Uniaxial and triaxial accelerometers do not differ in their measurement of PA in population studies, and either could be used in such studies.</p
    corecore