30 research outputs found
Validation of a simple dynamic thermal performance characterization model based on the piston flow concept for flat-plate solar collectors
A simple dynamic characterization model of flat-plate solar collectors based on the piston flow concept is used both to identify the collector characteristic parameters and to predict the dynamic thermal performance. The heat transport time originally defined as (1 − e−1)−1τC by Amrizal et al. (2012) for the model turns out to be the collector static response time constant τC by analytical derivation. The nonlinear least squares method is applied to determine the characteristic parameters of a flat-plate solar air collector previously tested by the authors. Then the obtained parameters are used to predict the dynamic behavior of the collector outlet temperature. The model coefficients particularly c3 in the simple dynamic characterization model are examined by the collector dynamic prediction under variable meteorological conditions. Meanwhile, the prediction accuracy of the simple dynamic model based on the first-order difference method is compared to that of the numerical solution of the collector ordinary differential equation (ODE) model using the fourth-order Runge-Kutta method. The improved thermal inertia model (TIM) on the basis of closed-form solution presented by Deng et al. (2016a) is also considered. The results show that the prediction performance of the simple dynamic model is nearly as accurate as the ODE numerical solution and the TIM by Deng et al. (2016a) except some special conditions such as sharply changed solar irradiance and collector inlet temperature
A CsI hodoscope on CSHINE for Bremsstrahlung {\gamma}-rays in Heavy Ion Reactions
Bremsstrahlung production in heavy ion reactions at Fermi energies
carries important physical information including the nuclear symmetry energy at
supra-saturation densities. In order to detect the high energy Bremsstrahlung
rays, a hodoscope consisting of 15 CsI(Tl) crystal read out by photo
multiplier tubes has been built, tested and operated in experiment. The
resolution, efficiency and linear response of the units to rays have
been studied using radioactive source and reactions. The
inherent energy resolution of is obtained.
Reconstruction method has been established through Geant 4 simulations,
reproducing the experimental results where comparison can be made. Using the
reconstruction method developed, the whole efficiency of the hodoscope is about
against the emissions at the target position,
exhibiting insignificant dependence on the energy of incident rays
above 20 MeV. The hodoscope is operated in the experiment of Kr +
Sn at 25 MeV/u, and a full energy spectrum up to 80 MeV has
been obtained.Comment: 9 pages, 19 figure
Probing high-momentum component in nucleon momentum distribution by neutron-proton bremsstrahlung {\gamma}-rays in heavy ion reactions
The high momentum tail (HMT) of nucleons, as a signature of the short-range
correlations in nuclei, has been investigated by the high-energy bremsstrahlung
rays produced in Kr + Sn at 25 MeV/u. The energetic
photons are measured by a CsI(Tl) hodoscope mounted on the spectrometer CSHINE.
The energy spectrum above 30 MeV can be reproduced by the IBUU model
calculations incorporating the photon production channel from process in
which the HMTs of nucleons is considered. A non-zero HMT ratio of about
is favored by the data. The effect of the capture channel is
demonstrated
Revisit to the yield ratio of triton and He as an indicator of neutron-rich neck emission
The neutron rich neck zone created in heavy ion reaction is experimentally
probed by the production of the isobars. The energy spectra and angular
distributions of triton and He are measured with the CSHINE detector in
Kr +Pb reactions at 25 MeV/u. While the energy spectrum of
He is harder than that of triton, known as "He-puzzle", the yield
ratio presents a robust rising trend with the polar angle in
laboratory. Using the fission fragments to reconstruct the fission plane, the
enhancement of out-plane is confirmed in comparison to the
in-plane ratios. Transport model simulations reproduce qualitatively the
experimental trends, but the quantitative agreement is not achieved. The
results demonstrate that a neutron rich neck zone is formed in the reactions.
Further studies are called for to understand the clustering and the isospin
dynamics related to neck formation
Systematic Method for the Energy-Saving Potential Calculation of Air Conditioning Systems via Data Mining. Part II: A Detailed Case Study
Increased data monitoring enables the energy-efficient operation of air-conditioning systems via data-mining. The latter is projected to have lesser consumption but more comprehensive diagnosis than traditional methods. Following the companion paper that proposed a systematic method for energy-saving potential calculations via data-mining, this article presents a detailed case study in an ice-storage air-conditioning system by employing the proposed method. Raw data were preprocessed prior to recognizing the constant- and variable-speed devices in the system. Classification and regression tree algorithms were utilized to identify the operating modes of the system. The regression models between the energy-consumption and operating-state parameters of the nine pumps and two chillers were fitted. Furthermore, the constraints pertaining to system operation were summarized. From the results, the particle swarm optimization method was applied to elucidate the benchmark energy cost and the consequent cost savings potential. The cost savings potential for the chiller plant room during the investigation duration of 59 d reached as high as 24.03%. The case study demonstrates the feasibility, effectiveness, and stability of the systematic approach. Further studies can facilitate the development of corresponding control strategies based on the potential analysis results, to investigate better optimization algorithm, and visualize the analysis process
Systematic Method for the Energy-Saving Potential Calculation of Air-Conditioning Systems via Data Mining. Part I: Methodology
Air-conditioning systems contribute the most to energy consumption among building equipment. Hence, energy saving for air-conditioning systems would be the essence of reducing building energy consumption. The conventional energy-saving diagnosis method through observation, test, and identification (OTI) has several drawbacks such as time consumption and narrow focus. To overcome these problems, this study proposed a systematic method for energy-saving diagnosis in air-conditioning systems based on data mining. The method mainly includes seven steps: (1) data collection, (2) data preprocessing, (3) recognition of variable-speed equipment, (4) recognition of system operation mode, (5) regression analysis of energy consumption data, (6) constraints analysis of system running, and (7) energy-saving potential analysis. A case study with a complicated air-conditioning system coupled with an ice storage system demonstrated the effectiveness of the proposed method. Compared with the traditional OTI method, the data-mining-based method can provide a more comprehensive analysis of energy-saving potential with less time cost, although it strongly relies on data quality in all steps and lacks flexibility for diagnosing specific equipment for energy-saving potential analysis. The results can deepen the understanding of the operating data characteristics of air-conditioning systems
Recognition of Variable-Speed Equipment in an Air-Conditioning System Using Numerical Analysis of Energy-Consumption Data
Motor-driven equipment (ME) is one of the key components in an air-conditioning system, which contributes to the vast majority of the total energy consumption by air-conditioning systems. Distinguishing variable- and constant-speed equipment is important since the energy simulation models of the two types differ. Traditionally, types of ME are known in advance, and energy consumption data are consequently analyzed. However, in the application scenarios of energy consumption data mining, precedent information on the ME type could be missing. Thus, this study applies this process in reverse, providing new insight into energy consumption data of ME to recognize variable-speed ME in an air-conditioning system. The energy consumption data of ME in an air-conditioning system implemented in a commercial building were collected and numerically analyzed. A proposed simple parameter, coefficient of the median, and several numerical parameters were calculated and used to distinguish variable- from constant-speed ME. Results showed that the energy consumption data distributions of the two types of ME differed. The proposed coefficient of the median could successfully distinguish variable- from constant-speed ME, and it could be applied as an important step in energy consumption data mining of air-conditioning systems
Investigation on Forced Convective Heat Transfer at the Building Façade with Louver Blinds under Different Wind Directions
Exterior louver blinds are one of the most common shading devices attached to the building façade, which will not only screen solar radiation but also affect the flow around the building and change the convective heat exchange at the façade. To better understand how different wind directions affect the convective heat properties of louvered building façades, this paper conducted a CFD simulation with the validation of previous wind-tunnel experiments. A total of 63 shading cases and 7 unshaded cases were both investigated by simulations. It was found that with the increase in wind attack angle θ, the surface-averaged convective heat transfer coefficient (CHTC) at the louvered surface will first increase by about 40~50% (θ from 0° to 60°) and then be cut down by 60% (θ from 60° to 90°). In addition, the convective heat exchange rate at the louver slats will gradually decrease with the growth of θ. Finally, modifications for previous correlations were proposed to quantify the effect of wind directions on the CHTCavg at the blinds and façade, of which the maximum deviation for convective heat exchange rate is less than 18%
Investigation on Forced Convective Heat Transfer at the Building Façade with Louver Blinds under Different Wind Directions
Exterior louver blinds are one of the most common shading devices attached to the building façade, which will not only screen solar radiation but also affect the flow around the building and change the convective heat exchange at the façade. To better understand how different wind directions affect the convective heat properties of louvered building façades, this paper conducted a CFD simulation with the validation of previous wind-tunnel experiments. A total of 63 shading cases and 7 unshaded cases were both investigated by simulations. It was found that with the increase in wind attack angle θ, the surface-averaged convective heat transfer coefficient (CHTC) at the louvered surface will first increase by about 40~50% (θ from 0° to 60°) and then be cut down by 60% (θ from 60° to 90°). In addition, the convective heat exchange rate at the louver slats will gradually decrease with the growth of θ. Finally, modifications for previous correlations were proposed to quantify the effect of wind directions on the CHTCavg at the blinds and façade, of which the maximum deviation for convective heat exchange rate is less than 18%