391 research outputs found

    The evaluation of the bone graft survival status in titanium cervical cages by radionuclide bone CT scan

    Get PDF
    To find a better way to evaluate the bone graft survival status in cervical cages, forty-one patients suffering from one-level cervical spondylosis were enrolled in this study. All underwent anterior cervical decompression and fusion with titanium cage and plate. When followed up, another 21 patients were confirmed as one-level cervical spondylosis without operation and were enrolled as control group. "Bolus" injection of radioactive 99mTc methylene diphosphonate (99mTc-MDP) with a dose of 25 ~ 30 mCi was performed through cubital vein, and radionuclide distribution images of cervical spine were obtained by single photon emission computed tomography/computed tomography (SPECT/CT). In sagittal view, bone graft was positioned accurately. By “region of interest” (ROI) technique, the same regions in bone graft and thoracic vertebra with the same level of suprasternal fossa were selected. Radioactive count ratio was then obtained. In the control group, “bone graft” was chosen on the inferior vertebra of the lesion segment, and the ratio was similarly gotten. Statistical difference was shown between bone graft group and control group by t test (t = 2.713, P < 0.05). The bone graft survival rate was 100% by SPECT/CT and bony fusion rate was 92.7% by CT scan. It indicated that in all bony fusion cases, bone graft survived; however, the bone survival was not surely together with bony fusion.Key words: Bone graft, titanium cervical cage, radionuclide bone CT

    MicroShunt versus trabeculectomy for surgical management of glaucoma: a retrospective analysis

    Get PDF
    This case-control study aims to compare the efficacy, safety, and postoperative burden of MicroShunt versus trabeculectomy. The first consecutive cohort of MicroShunt procedures (n = 101) was matched to recent historical trabeculectomy procedures (n = 101) at two London hospital trusts. Primary endpoints included changes in intraocular pressure (IOP) and glaucoma medications. Secondary outcome measures included changes in retinal nerve fibre layer (RNFL) thickness, rates of complications, further theatre interventions, and the number of postoperative visits. From the baseline to Month-18, the median [interquartile range] IOP decreased from 22 [17–29] mmHg (on 4 [3–4] medications) to 15 [10–17] mmHg (on 0 [0–2] medications) and from 20 [16–28] mmHg (on 4 [3–4] medications) to 11 [10–13] mmHg (on 0 [0–0] medications) in the MicroShunt and trabeculectomy groups, respectively. IOP from Month-3 was significantly higher in the MicroShunt group (p = 0.006), with an increased number of medications from Month-12 (p = 0.024). There were greater RNFL thicknesses from Month-6 in the MicroShunt group (p = 0.005). The rates of complications were similar (p = 0.060) but with fewer interventions (p = 0.031) and postoperative visits (p = 0.001) in the MicroShunt group. Therefore, MicroShunt has inferior efficacy to trabeculectomy in lowering IOP and medications but provides a better safety profile and postoperative burden and may delay RNFL loss

    Ultrasensitive PCR system for HBV DNA detection: Risk stratification for occult hepatitis B virus infection in English blood donors

    Get PDF
    Occult hepatitis B (HBV) infection (OBI), characterized by low viral loads, accounts for much of the risk of HBV transfusion-transmitted infection. With anticore antibodies (anti-HBc) screening introduced in England, the imperative to identify OBI donors has increased. We aimed to develop an ultra-sensitive PCR system and investigate risk factors for HBV DNA presence in blood donations. Seven extraction methods and three PCR assays were compared. The optimal system was sought to determine HBV DNA presence in anti-HBc-positive donations. Predictors of DNA positivity were subsequently investigated. Extraction from 5 mL of plasma increased sample representation and resulted in HBV DNA detection in low viral load samples (~0.5 IU/mL). Screening of 487 763 donations in 2022 identified two OBI donors and 2042 anti-HBc-positive donors, 412 of the latter with anti-HBs < 100 mIU/mL. Testing of 134 anti-HBc-positive donations utilizing the 5 mL extraction method identified two further HBV DNA-positive donations. Higher anti-HBc titer and anti-HBs negativity were significant predictors of DNA detectability in anti-HBc-positive donations. An ultrasensitive PCR assay identified potentially infectious donations increasing HBV DNA detection in anti-HBc-positive donors from 0.5% to 1.9%. Anti-HBc titers may further complement the risk stratification for DNA positivity in anti-HBc screening and minimize unnecessary donor deferral

    Generating MHV super-vertices in light-cone gauge

    Full text link
    We constructe the N=1\mathcal{N}=1 SYM lagrangian in light-cone gauge using chiral superfields instead of the standard vector superfield approach and derive the MHV lagrangian. The canonical transformations of the gauge field and gaugino fields are summarised by the transformation condition of chiral superfields. We show that N=1\mathcal{N}=1 MHV super-vertices can be described by a formula similar to that of the N=4\mathcal{N}=4 MHV super-amplitude. In the discussions we briefly remark on how to derive Nair's formula for N=4\mathcal{N}=4 SYM theory directly from light-cone lagrangian.Comment: 25 pages, 7 figures, JHEP3 style; v2: references added, some typos corrected; Clarification on the condition used to remove one Grassmann variabl

    Exact distribution of a pattern in a set of random sequences generated by a Markov source: applications to biological data

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In bioinformatics it is common to search for a pattern of interest in a potentially large set of rather short sequences (upstream gene regions, proteins, exons, etc.). Although many methodological approaches allow practitioners to compute the distribution of a pattern count in a random sequence generated by a Markov source, no specific developments have taken into account the counting of occurrences in a set of independent sequences. We aim to address this problem by deriving efficient approaches and algorithms to perform these computations both for low and high complexity patterns in the framework of homogeneous or heterogeneous Markov models.</p> <p>Results</p> <p>The latest advances in the field allowed us to use a technique of optimal Markov chain embedding based on deterministic finite automata to introduce three innovative algorithms. Algorithm 1 is the only one able to deal with heterogeneous models. It also permits to avoid any product of convolution of the pattern distribution in individual sequences. When working with homogeneous models, Algorithm 2 yields a dramatic reduction in the complexity by taking advantage of previous computations to obtain moment generating functions efficiently. In the particular case of low or moderate complexity patterns, Algorithm 3 exploits power computation and binary decomposition to further reduce the time complexity to a logarithmic scale. All these algorithms and their relative interest in comparison with existing ones were then tested and discussed on a toy-example and three biological data sets: structural patterns in protein loop structures, PROSITE signatures in a bacterial proteome, and transcription factors in upstream gene regions. On these data sets, we also compared our exact approaches to the tempting approximation that consists in concatenating the sequences in the data set into a single sequence.</p> <p>Conclusions</p> <p>Our algorithms prove to be effective and able to handle real data sets with multiple sequences, as well as biological patterns of interest, even when the latter display a high complexity (PROSITE signatures for example). In addition, these exact algorithms allow us to avoid the edge effect observed under the single sequence approximation, which leads to erroneous results, especially when the marginal distribution of the model displays a slow convergence toward the stationary distribution. We end up with a discussion on our method and on its potential improvements.</p

    Observation of a ppb mass threshoud enhancement in \psi^\prime\to\pi^+\pi^-J/\psi(J/\psi\to\gamma p\bar{p}) decay

    Full text link
    The decay channel ψπ+πJ/ψ(J/ψγppˉ)\psi^\prime\to\pi^+\pi^-J/\psi(J/\psi\to\gamma p\bar{p}) is studied using a sample of 1.06×1081.06\times 10^8 ψ\psi^\prime events collected by the BESIII experiment at BEPCII. A strong enhancement at threshold is observed in the ppˉp\bar{p} invariant mass spectrum. The enhancement can be fit with an SS-wave Breit-Wigner resonance function with a resulting peak mass of M=186113+6(stat)26+7(syst)MeV/c2M=1861^{+6}_{-13} {\rm (stat)}^{+7}_{-26} {\rm (syst)} {\rm MeV/}c^2 and a narrow width that is Γ<38MeV/c2\Gamma<38 {\rm MeV/}c^2 at the 90% confidence level. These results are consistent with published BESII results. These mass and width values do not match with those of any known meson resonance.Comment: 5 pages, 3 figures, submitted to Chinese Physics
    corecore