134 research outputs found

    Thermally induced rotation of 3d orbital stripes in Pr(Sr0.1Ca0.9)(2)Mn2O7

    Get PDF
    We have investigated orbital ordering in the bilayer manganite, Pr(Sr0.1Ca0.9)2Mn2O7, using synchrotron x-ray diffraction techniques, in particular resonant soft x-ray diffraction. Diffraction signals are observed at (0,12,0) above 300 K and (12,0,0) below 300 K, corresponding to orbital stripes along the a and b axes, respectively. The previously observed transition at 300 K is evidence of a rotation of the orientation of the 3d orbital stripes. Large resonances of the orbital signals are observed at the Mn L edges, with a complex dependence on incident photon energy indicative of a weakly Jahn-Teller distorted system. A structural transition observed at 92 K is found not to involve a further change in the orbital order

    Comparison of exhaled breath condensate pH using two commercially available devices in healthy controls, asthma and COPD patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Analysis of exhaled breath condensate (EBC) is a non-invasive method for studying the acidity (pH) of airway secretions in patients with inflammatory lung diseases.</p> <p>Aim</p> <p>To assess the reproducibility of EBC pH for two commercially available devices (portable RTube and non-portable ECoScreen) in healthy controls, patients with asthma or COPD, and subjects suffering from an acute cold with lower-airway symptoms. In addition, we assessed the repeatability in healthy controls.</p> <p>Methods</p> <p>EBC was collected from 40 subjects (n = 10 in each of the above groups) using RTube and ECoScreen. EBC was collected from controls on two separate occasions within 5 days. pH in EBC was assessed after degasification with argon for 20 min.</p> <p>Results</p> <p>In controls, pH-measurements in EBC collected by RTube or ECoScreen showed no significant difference between devices (p = 0.754) or between days (repeatability coefficient RTube: 0.47; ECoScreen: 0.42) of collection. A comparison between EBC pH collected by the two devices in asthma, COPD and cold patients also showed good reproducibility. No differences in pH values were observed between controls (mean pH 8.27; RTube) and patients with COPD (pH 7.97) or asthma (pH 8.20), but lower values were found using both devices in patients with a cold (pH 7.56; RTube, p < 0.01; ECoScreen, p < 0.05).</p> <p>Conclusion</p> <p>We conclude that pH measurements in EBC collected by RTube and ECoScreen are repeatable and reproducible in healthy controls, and are reproducible and comparable in healthy controls, COPD and asthma patients, and subjects with a common cold.</p

    Quadriceps force generation in patients with osteoarthritis of the knee and asymptomatic participants during patellar tendon reflex reactions: an exploratory cross-sectional study

    Get PDF
    BACKGROUND: It has been postulated that muscle contraction is slower in patients with osteoarthritis of the knee than asymptomatic individuals, a factor that could theoretically impair joint protection mechanisms. This study investigated whether patients with osteoarthritis of the knee took longer than asymptomatic participants to generate force during reflex quadriceps muscle contraction. This was an exploratory study to inform sample size for future studies. METHODS: An exploratory observational cross sectional study was carried out. Two subject groups were tested, asymptomatic participants (n = 17), mean (SD) 56.7 (8.6) years, and patients with osteoarthritis of the knee, diagnosed by an orthopaedic surgeon, (n = 16), age 65.9 (7.8) years. Patellar tendon reflex responses were elicited from participants and measured with a load cell. Force latency, contraction time, and force of the reflex response were determined from digitally stored data. The Mann-Whitney U test was used for the between group comparisons in these variables. Bland and Altman within-subject standard deviation values were calculated to evaluate the measurement error or precision of force latency and contraction time. RESULTS: No significant differences were found between the groups for force latency (p = 0.47), contraction time (p = 0.91), or force (p = 0.72). The two standard deviation measurement error values for force latency were 27.9 ms for asymptomatic participants and 16.4 ms for OA knee patients. For contraction time, these values were 29.3 ms for asymptomatic participants and 28.1 ms for OA knee patients. Post hoc calculations revealed that the study was adequately powered (80%) to detect a difference between the groups of 30 ms in force latency. However it was inadequately powered (59%) to detect this same difference in contraction time, and 28 participants would be required in each group to reach 80% power. CONCLUSION: Patients with osteoarthritis of the knee do not appear to have compromised temporal parameters or magnitude of force generation during patellar tendon reflex reactions when compared to a group of asymptomatic participants. However, these results suggest that larger studies are carried out to investigate this area further

    A simple, reproducible method for monitoring the treatment of tumours using dynamic contrast-enhanced MR imaging

    Get PDF
    Dynamic contrast-enhanced MR imaging (DCE-MRI) may act as a biomarker for successful cancer therapy. Simple, reproducible techniques may widen this application. This paper demonstrates a single slice imaging technique. The image acquisition is performed in less than 500 ms making it relatively insensitive to respiratory motion. Data from phantom studies and a reproducibility study in solid human tumours are presented. The reproducibility study showed a coefficient of variation (CoV) of 19.1% for Ktrans and 15.8% for the initial area under the contrast enhancement curve (IAUC). This was improved to 16 and 13.9% if tumours of diameter less than 3 cm were excluded. The individual repeatability (the range within which individual measurements are expected to fall) was 30.6% for Ktrans and 26.5% for IAUC for tumours greater than 3 cm diameter. This approach to DCE–MRI image acquisition can be performed with standard clinical scanners, and data analysis is straightforward. For treatment trials with 10 patients in a cohort, the CoV implies that the method would be sensitive to a treatment effect of greater than 18%. The individual repeatability is well inside the 40% change shown to be important in clinical studies using this DCE–MRI technique

    Remote heart rate monitoring - Assessment of the Facereader rPPg by Noldus

    Get PDF
    Remote photoplethysmography (rPPG) allows contactless monitoring of human cardiac activity through a video camera. In this study, we assessed the accuracy and precision for heart rate measurements of the only consumer product available on the market, namely the Facereaderâ„¢ rPPG by Noldus, with respect to a gold standard electrocardiograph. Twenty-four healthy participants were asked to sit in front of a computer screen and alternate two periods of rest with two stress tests (i.e. Go/No-Go task), while their heart rate was simultaneously acquired for 20 minutes using the ECG criterion measure and the Facereaderâ„¢ rPPG. Results show that the Facereaderâ„¢ rPPG tends to overestimate lower heart rates and underestimate higher heart rates compared to the ECG. The Facereaderâ„¢ rPPG revealed a mean bias of 9.8 bpm, the 95% limits of agreement (LoA) ranged from almost -30 up to +50 bpm. These results suggest that whilst the rPPG Facereaderâ„¢ technology has potential for contactless heart rate monitoring, its predictions are inaccurate for higher heart rates, with unacceptable precision across the entire range, rendering its estimates unreliable for monitoring individuals

    The Effect of Polyhydramnios on Cervical Length in Twins: A Controlled Intervention Study in Complicated Monochorionic Pregnancies

    Get PDF
    Objective: To test the hypothesis that cervical shortening in polyhydramnios reflects the degree of excess amniotic fluid, and increases with normalisation of amniotic fluid volume. Study Design: Prospective cohort study of 40 women with monochorionic twins undergoing interventional procedures between 16-26 weeks. Cervical length was assessed via transvaginal sonography pre-procedure, 1 and 24 hours postprocedure, and results compared between amnioreduction and control procedures. Amniotic fluid index (AFI) was measured pre- and post-procedure. Results: Pre-procedural cervical length correlated with AFI (linear fit = 5.07 -0.04x, R2 = 0.17, P = 0.03) in patients with polyhydramnios (n = 28). Drainage of 2000ml fluid (range 700-3500ml), reduced AFI from 42cm to 21cm (P>0.001). Their pre-procedural cervical length did not change at one (mean Δ:-0.1cm, 95%CI, -0.4 to 0.2) or 24 hours (0.2cm, -0.1 to 0.6) after amnioreduction. There was no change in cervical length at control procedures. Conclusion: Cervical shortening in twins with polyhydramnios does not appear to be an acute process; cervical length can be measured before or after therapeutic procedures. © 2008 Engineer et al

    A rapid high-performance semi-automated tool to measure total kidney volume from MRI in autosomal dominant polycystic kidney disease.

    Get PDF
    OBJECTIVES: To develop a high-performance, rapid semi-automated method (Sheffield TKV Tool) for measuring total kidney volume (TKV) from magnetic resonance images (MRI) in patients with autosomal dominant polycystic kidney disease (ADPKD). METHODS: TKV was initially measured in 61 patients with ADPKD using the Sheffield TKV Tool and its performance compared to manual segmentation and other published methods (ellipsoidal, mid-slice, MIROS). It was then validated using an external dataset of MRI scans from 65 patients with ADPKD. RESULTS: Sixty-one patients (mean age 45 ± 14 years, baseline eGFR 76 ± 32 ml/min/1.73 m2) with ADPKD had a wide range of TKV (258-3680 ml) measured manually. The Sheffield TKV Tool was highly accurate (mean volume error 0.5 ± 5.3% for right kidney, - 0.7 ± 5.5% for left kidney), reproducible (intra-operator variability - 0.2 ± 1.3%; inter-operator variability 1.1 ± 2.9%) and outperformed published methods. It took less than 6 min to execute and performed consistently with high accuracy in an external MRI dataset of T2-weighted sequences with TKV acquired using three different scanners and measured using a different segmentation methodology (mean volume error was 3.45 ± 3.96%, n = 65). CONCLUSIONS: The Sheffield TKV Tool is operator friendly, requiring minimal user interaction to rapidly, accurately and reproducibly measure TKV in this, the largest reported unselected European patient cohort with ADPKD. It is more accurate than estimating equations and its accuracy is maintained at larger kidney volumes than previously reported with other semi-automated methods. It is free to use, can run as an independent executable and will accelerate the application of TKV as a prognostic biomarker for ADPKD into clinical practice. KEY POINTS: • This new semi-automated method (Sheffield TKV Tool) to measure total kidney volume (TKV) will facilitate the routine clinical assessment of patients with ADPKD. • Measuring TKV manually is time consuming and laborious. • TKV is a prognostic indicator in ADPKD and the only imaging biomarker approved by the FDA and EMA
    • …
    corecore