381 research outputs found

    That lung cancer incidence falls in ex-smokers: misconceptions 2

    Get PDF
    Misconceptions and ill-founded theories can arise in all areas of science. However, the apparent accessibility of many epidemiology findings and popular interest in the subject can lead to additional misunderstandings. The article below continues an occasional series of short editorials highlighting some current misinterpretations of epidemiological findings. Invited authors will be given wide scope in judging the prevalence of the misconception under discussion. We hope that this series will prove instructive to cancer researchers in other disciplines as well as to students of epidemiology. Adrian L Harris and Leo Kinle

    Progression free survival of myeloma patients who become IFE-negative correlates with the detection of residual monoclonal free light chain (FLC) by mass spectrometry

    Get PDF
    \ua9 The Author(s) 2024.Deeper responses are associated with improved survival in patients being treated for myeloma. However, the sensitivity of the current blood-based assays is limited. Historical studies suggested that normalisation of the serum free light chain (FLC) ratio in patients who were negative by immunofixation electrophoresis (IFE) was associated with improved outcomes. However, recently this has been called into question. Mass spectrometry (MS)-based FLC assessments may offer a superior methodology for the detection of monoclonal FLC due to greater sensitivity. To test this hypothesis, all available samples from patients who were IFE negative after treatment with carfilzomib and lenalidomide-based induction and autologous stem cell transplantation (ASCT) in the Myeloma XI trial underwent FLC-MS testing. FLC-MS response assessments from post-induction, day+100 post-ASCT and six months post-maintenance randomisation were compared to serum FLC assay results. Almost 40% of patients had discordant results and 28.7% of patients with a normal FLC ratio had residual monoclonal FLC detectable by FLC-MS. FLC-MS positivity was associated with reduced progression-free survival (PFS) but an abnormal FLC ratio was not. This study demonstrates that FLC-MS provides a superior methodology for the detection of residual monoclonal FLC with FLC-MS positivity identifying IFE-negative patients who are at higher risk of early progression

    Rate-Response Programming Tailored to the Force-Frequency Relationship Improves Exercise Tolerance in Chronic Heart Failure

    Get PDF
    Objectives: This study sought to examine whether the heart rate (HR) at which the force-frequency relationship (FFR) slope peaks (critical HR) could be used to tailor HR response in chronic heart failure (CHF) patients with cardiac pacemakers and whether this favorably influences exercise capacity. Background: CHF secondary to left ventricular (LV) systolic dysfunction is characterized by blunting of the positive relationship between HR and LV contractility known as the FFR. Methods: This observational study was carried out in patients with CHF and healthy subjects with pacemaker devices. The study assessed the 3 important features of the FFR (critical HR, peak contractility, and the FFR slope), and their reproducibility was measured noninvasively using echocardiography. The investigators then undertook a double-blind, randomized, controlled crossover study comparing the effects of tailored pacemaker rate-response programming on the basis of the FFR with conventional rate-response programming on exercise time and maximal oxygen consumption. Results: The study enrolled 90 patients with CHF into the observational cohort study: mean age, 73.6 ± 8.9 years; mean left ventricular ejection fraction (LVEF), 33.5 ± 10.9%. The study investigated 15 control subjects with normal LV function (LVEF, 55.6 ± 5.3%). The critical HR (103 ± 22 beats/min vs. 126 ± 15 beats/min; p = 0.0002), peak contractility (3.8 ± 3.7 SBP/LVESVI vs. 9.8 ± 4.1 SBP/LVESVI; p = 0.0001), and the slope of the FFR (p < 10−15) were lower in patients with CHF than in control subjects. A total of 52 patients, with a mean LVEF of 32 ± 11% on optimal therapy, took part in the crossover study. Rate-response settings limiting HR rise to below the critical HR led to greater exercise time (475 ± 189 s vs. 425 ± 196 s; p = 0.003) and higher peak oxygen consumption (17.3 ± 4.6 ml/kg/min vs. 16.6 ± 4.7 ml/kg/min; p = 0.01). Conclusions: A personalized approach to rate-response programming, determined using a reproducible noninvasive method for assessing the FFR, improves exercise time in patients with CHF and pacemaker devices. (Bowditch Revisited: Defining the Optimum Heart Rate Range in Chronic Heart Failure; NCT02563873

    A change in the transportation needs today, a better future for tomorrow – climate change review

    Get PDF
    No sooner than later, the world will be living hell as a result of the transportation effects on our climate now escalating. The pressure is now growing towards their resultant effects to be totally eradicated in order to save our planet otherwise, the stabilisation of these effects; global warming, greenhouse gas (GHG) emission and degradation will need to be sought after. The world all over is at it now in an effort to restore our climate, to save it from the effects of these catastrophes/disasters. On the proposition of the Kyoto Protocol in1997, the main focus was to decrease greenhouse emissions of mainly six gases – Carbon dioxide, methane, nitrous oxide, sulphur hexafluoride, Hydro fluorocarbons (HFCs) and Per fluorinated Compounds (PFCs). And transport alone, accounts for over 26% of global CO2 and has been regarded as one of the few industrial sectors wherein emissions are still on the increase, on this basis, researchers and policy makers are all at it to tackle the menace of climate changes through provision of sustainable transport. This paper focuses on the new and developed technologies like the renewable energy source [RES], which will be an alternative to transport fuels to avoid the dependence on petroleum which after effects are damaging to the world climate, and may probably not be there forever to continue serving the world ever increasing population. While the long term solutions are being sought, these alternatives will make do for now

    Variation of health-related quality of life assessed by caregivers and patients affected by severe childhood infections.

    Get PDF
    BACKGROUND: The agreement between self-reported and proxy measures of health status in ill children is not well established. This study aimed to quantify the variation in health-related quality of life (HRQOL) derived from young patients and their carers using different instruments. METHODS: A hospital-based cross-sectional survey was conducted between August 2010 and March 2011. Children with meningitis, bacteremia, pneumonia, acute otitis media, hearing loss, chronic lung disease, epilepsy, mild mental retardation, severe mental retardation, and mental retardation combined with epilepsy, aged between five to 14 years in seven tertiary hospitals were selected for participation in this study. The Health Utilities Index Mark 2 (HUI2), and Mark 3 (HUI3), and the EuroQoL Descriptive System (EQ-5D) and Visual Analogue Scale (EQ-VAS) were applied to both paediatric patients (self-assessment) and caregivers (proxy-assessment). RESULTS: The EQ-5D scores were lowest for acute conditions such as meningitis, bacteremia, and pneumonia, whereas the HUI3 scores were lowest for most chronic conditions such as hearing loss and severe mental retardation. Comparing patient and proxy scores (n = 74), the EQ-5D exhibited high correlation (r = 0.77) while in the HUI2 and HUI3 patient and caregiver scores were moderately correlated (r = 0.58 and 0.67 respectively). The mean difference between self and proxy-assessment using the HUI2, HUI3, EQ-5D and EQ-VAS scores were 0.03, 0.05, -0.03 and -0.02, respectively. In hearing-impaired and chronic lung patients the self-rated HRQOL differed significantly from their caregivers. CONCLUSIONS: The use of caregivers as proxies for measuring HRQOL in young patients affected by pneumococcal infection and its sequelae should be employed with caution. Given the high correlation between instruments, each of the HRQOL instruments appears acceptable apart from the EQ-VAS which exhibited low correlation with the others

    An exploration of parents’ preferences for foot care in juvenile idiopathic arthritis: a possible role for the discrete choice experiment

    Get PDF
    Background: An increased awareness of patients’ and parents’ care preferences regarding foot care is desirable from a clinical perspective as such information may be utilised to optimise care delivery. The aim of this study was to examine parents’ preferences for, and valuations of foot care and foot-related outcomes in juvenile idiopathic arthritis (JIA).&lt;p&gt;&lt;/p&gt; Methods: A discrete choice experiment (DCE) incorporating willingness-to-pay (WTP) questions was conducted by surveying 42 parents of children with JIA who were enrolled in a randomised-controlled trial of multidisciplinary foot care at a single UK paediatric rheumatology outpatients department. Attributes explored were: levels of pain; mobility; ability to perform activities of daily living (ADL); waiting time; referral route; and footwear. The DCE was administered at trial baseline. DCE data were analysed using a multinomial-logit-regression model to estimate preferences and relative importance of attributes of foot care. A stated-preference WTP question was presented to estimate parents’ monetary valuation of health and service improvements.&lt;p&gt;&lt;/p&gt; Results: Every attribute in the DCE was statistically significant (p &#60; 0.01) except that of cost (p = 0.118), suggesting that all attributes, except cost, have an impact on parents’ preferences for foot care for their child. The magnitudes of the coefficients indicate that the strength of preference for each attribute was (in descending order): improved ability to perform ADL, reductions in foot pain, improved mobility, improved ability to wear desired footwear, multidisciplinary foot care route, and reduced waiting time. Parents’ estimated mean annual WTP for a multidisciplinary foot care service was £1,119.05.&lt;p&gt;&lt;/p&gt; Conclusions: In terms of foot care service provision for children with JIA, parents appear to prefer improvements in health outcomes over non-health outcomes and service process attributes. Cost was relatively less important than other attributes suggesting that it does not appear to impact on parents’ preferences.&lt;p&gt;&lt;/p&gt

    Diagnosis and monitoring for light chain only and oligosecretory myeloma using serum free light chain tests

    Get PDF
    This study aims to guide the integration of serum free light chain (sFLC) tests into clinical practice, including a new rapid test (Seralite®). Blood and urine analysis from 5573 newly diagnosed myeloma patients identified 576 light chain only (LCO) and 60 non-secretory (NS) cases. Serum was tested by Freelite® and Seralite® at diagnosis, maximum response and relapse. 20% of LCO patients had urine FLC levels below that recommended for measuring response but >97% of these had adequate sFLC levels (oligosecretory). The recommended Freelite® sFLC ≥100 mg/l for measuring response was confirmed and the equivalent Seralite® FLC difference (dFLC) >20 mg/l identified. By both methods, ≥38% of NS patients had measurable disease (oligosecretory). Higher sFLC levels were observed on Freelite® at all time points. However, good clinical concordance was observed at diagnosis and in response to therapy. Achieving at least a very good partial response according to either sFLC method was associated with better patient survival. Relapse was identified using a Freelite® sFLC increase >200 mg/l and found 100% concordance with a corresponding Seralite® dFLC increase >30 mg/l. Both Freelite® and Seralite® sensitively diagnose and monitor LCO/oligosecretory myeloma. Rapid testing by Seralite® could fast-track FLC screening and monitoring. Response by sFLC assessment was prognostic for survival and demonstrates the clinical value of routine sFLC testing
    corecore