354 research outputs found

    PKSB1740-517: An ALMA view of the cold gas feeding a distant interacting young radio galaxy

    Get PDF
    Cold neutral gas is a key ingredient for growing the stellar and central black hole mass in galaxies throughout cosmic history. We have used the Atacama Large Millimetre Array (ALMA) to detect a rare example of redshifted 12^{12}CO(2-1) absorption in PKS B1740-517, a young (t∼1.6×103t \sim 1.6 \times 10^{3} yr) and luminous (L5GHz∼6.6×1043L_{\rm 5 GHz} \sim 6.6 \times 10^{43} erg s−1^{-1} ) radio galaxy at z=0.44z = 0.44 that is undergoing a tidal interaction with at least one lower-mass companion. The coincident HI 21-cm and molecular absorption have very similar line profiles and reveal a reservoir of cold gas (Mgas∼107−108M_{\rm gas} \sim 10^{7} - 10^{8} M⊙_{\odot}), likely distributed in a disc or ring within a few kiloparsecs of the nucleus. A separate HI component is kinematically distinct and has a very narrow line width (ΔvFWHM≲5\Delta{v}_{\rm FWHM} \lesssim 5 km s−1^{-1}), consistent with a single diffuse cloud of cold (Tk∼100T_{\rm k} \sim 100 K) atomic gas. The 12^{12}CO(2-1) absorption is not associated with this component, which suggests that the cloud is either much smaller than 100 pc along our sight-line and/or located in low-metallicity gas that was possibly tidally stripped from the companion. We argue that the gas reservoir in PKS B1740-517 may have accreted onto the host galaxy ∼\sim50 Myr before the young radio AGN was triggered, but has only recently reached the nucleus. This is consistent with the paradigm that powerful luminous radio galaxies are triggered by minor mergers and interactions with low-mass satellites and represent a brief, possibly recurrent, active phase in the life cycle of massive early type galaxies.Comment: 15 pages, 7 figures, accepted for publication in MNRA

    The Dutch version of the Oral Health Impact Profile (OHIP-NL): Translation, reliability and construct validity

    Get PDF
    Background The purpose of this study was to make a cross-culturally adapted, Dutch version of the Oral Health Impact Profile (OHIP), a 49-item questionnaire measuring oral health-related quality of life, and to examine its psychometric properties. Methods The original English version of the OHIP was translated into the Dutch language, following the guidelines for cross-cultural adaptation of health-related quality of life measures. The resulting OHIP-NL's psychometric properties were examined in a sample of 119 patients (68.9 % women; mean age = 57.1 ± 12.2 yrs). They were referred to the clinic of Prosthodontics and Implantology with complaints concerning their partial or full dentures or other problems with missing teeth. To establish the reliability of the OHIP-NL, internal consistency and test-retest reliability (N = 41; 1 - 2 weeks interval) were examined, using Cronbach's alpha and intraclass correlation coefficients (ICC), respectively. Further, construct validity was established by calculating ANOVA. Results Internal consistency and test-retest reliability were excellent (Cronbach's alpha = 0.82 - 0.97; ICC = 0.78 - 0.90). In addition, all associations were significant and in the expected direction. Conclusion In conclusion: the OHIP-NL can be considered a reliable and valid instrument to measure oral health-related quality of life

    The Effectiveness of Alcohol Screening and Brief Intervention in Emergency Departments: A Multicentre Pragmatic Cluster Randomized Controlled Trial

    Get PDF
    BACKGROUND: Alcohol misuse is common in people attending emergency departments (EDs) and there is some evidence of efficacy of alcohol screening and brief interventions (SBI). This study investigated the effectiveness of SBI approaches of different intensities delivered by ED staff in nine typical EDs in England: the SIPS ED trial. METHODS AND FINDINGS: Pragmatic multicentre cluster randomized controlled trial of SBI for hazardous and harmful drinkers presenting to ED. Nine EDs were randomized to three conditions: a patient information leaflet (PIL), 5 minutes of brief advice (BA), and referral to an alcohol health worker who provided 20 minutes of brief lifestyle counseling (BLC). The primary outcome measure was the Alcohol Use Disorders Identification Test (AUDIT) status at 6 months. Of 5899 patients aged 18 or more presenting to EDs, 3737 (63·3%) were eligible to participate and 1497 (40·1%) screened positive for hazardous or harmful drinking, of whom 1204 (80·4%) gave consent to participate in the trial. Follow up rates were 72% (n?=?863) at six, and 67% (n?=?810) at 12 months. There was no evidence of any differences between intervention conditions for AUDIT status or any other outcome measures at months 6 or 12 in an intention to treat analysis. At month 6, compared to the PIL group, the odds ratio of being AUDIT negative for brief advice was 1·103 (95% CI 0·328 to 3·715). The odds ratio comparing BLC to PIL was 1·247 (95% CI 0·315 to 4·939). A per protocol analysis confirmed these findings. CONCLUSIONS: SBI is difficult to implement in typical EDs. The results do not support widespread implementation of alcohol SBI in ED beyond screening followed by simple clinical feedback and alcohol information, which is likely to be easier and less expensive to implement than more complex interventions

    Accuracy and repeatability of wrist joint angles in boxing using an electromagnetic tracking system

    Get PDF
    © 2019, The Author(s). The hand-wrist region is reported as the most common injury site in boxing. Boxers are at risk due to the amount of wrist motions when impacting training equipment or their opponents, yet we know relatively little about these motions. This paper describes a new method for quantifying wrist motion in boxing using an electromagnetic tracking system. Surrogate testing procedure utilising a polyamide hand and forearm shape, and in vivo testing procedure utilising 29 elite boxers, were used to assess the accuracy and repeatability of the system. 2D kinematic analysis was used to calculate wrist angles using photogrammetry, whilst the data from the electromagnetic tracking system was processed with visual 3D software. The electromagnetic tracking system agreed with the video-based system (paired t tests) in both the surrogate ( 0.9). In the punch testing, for both repeated jab and hook shots, the electromagnetic tracking system showed good reliability (ICCs > 0.8) and substantial reliability (ICCs > 0.6) for flexion–extension and radial-ulnar deviation angles, respectively. The results indicate that wrist kinematics during punching activities can be measured using an electromagnetic tracking system

    The influence of minimum sitting period of the ActivPALâ„¢ on the measurement of breaks in sitting in young children

    Get PDF
    Sitting time and breaks in sitting influence cardio-metabolic health. New monitors (e.g. activPALâ„¢) may be more accurate for measurement of sitting time and breaks in sitting although how to optimize measurement accuracy is not yet clear. One important issue is the minimum sitting/upright period (MSUP) to define a new posture. Using the activPALâ„¢, we investigated the effect of variations in MSUP on total sitting time and breaks in sitting, and also determined the criterion validity of different activPALâ„¢ settings for both construct

    Spanish version of the Oral Health Impact Profile (OHIP-Sp)

    Get PDF
    BACKGROUND: The need for appraisal of oral health-related quality of life has been increasingly recognized over the last decades. The aims of this study were to develop a Spanish version (OHIP-Sp) of the Oral Health Impact Profile and to evaluate its convergent and discriminative validity, and its internal consistency. METHODS: The original 49-items OHIP was translated to Spanish, revised for understanding and semantics by two independent dentists, and then translated back to English by an independent bilingual dentist. The data originated in a cross sectional study conducted among high school students from the Province of Santiago, Chile. The study group was sampled using a multistage random cluster procedure yielding 9,203 students aged 12–21 years. All selected students were invited to participate and all filled a questionnaire with information on socio-demographic factors; oral health related behaviors; and self-reported oral health status (good, fair or poor). From this group, 9,163 students also accepted to fill a detailed questionnaire on socio-economic indicators and to receive a clinical examination comprising direct recordings of clinical attachment levels (CAL) in molars and incisors, tooth loss, and the presence of necrotizing ulcerative gingival lesions. RESULTS: The participation rate and the questionnaire completeness were high with OHIP-Sp total scores being computed for 9,133 subjects. Self-perceived oral health status was associated with the total OHIP-Sp score and all its domains (Spearman rank correlation). The OHIP-Sp total score was also directly associated with the 4 dental outcomes investigated (Mann-Whitney test) and the largest impact was found for the outcomes, 'tooth loss' with a mean OHIP-Sp score = 13.5 and 'CAL >= 3 mm' with a mean OHIP-Sp score = 13.0. CONCLUSION: The OHIP-Sp revealed suitable convergent and discriminative validity and appropriate internal consistency (Cronbach's α). Further studies on OHIP-Sp warrant the inclusion of populations with a higher disease burden; and the use of test-retest reliability exercises to evaluate the stability of the test

    Determination of Baroreflex Sensitivity during the Modified Oxford Maneuver by Trigonometric Regressive Spectral Analysis

    Get PDF
    BACKGROUND: Differences in spontaneous and drug-induced baroreflex sensitivity (BRS) have been attributed to its different operating ranges. The current study attempted to compare BRS estimates during cardiovascular steady-state and pharmacologically stimulation using an innovative algorithm for dynamic determination of baroreflex gain. METHODOLOGY/PRINCIPAL FINDINGS: Forty-five volunteers underwent the modified Oxford maneuver in supine and 60° tilted position with blood pressure and heart rate being continuously recorded. Drug-induced BRS-estimates were calculated from data obtained by bolus injections of nitroprusside and phenylephrine. Spontaneous indices were derived from data obtained during rest (stationary) and under pharmacological stimulation (non-stationary) using the algorithm of trigonometric regressive spectral analysis (TRS). Spontaneous and drug-induced BRS values were significantly correlated and display directionally similar changes under different situations. Using the Bland-Altman method, systematic differences between spontaneous and drug-induced estimates were found and revealed that the discrepancy can be as large as the gain itself. Fixed bias was not evident with ordinary least products regression. The correlation and agreement between the estimates increased significantly when BRS was calculated by TRS in non-stationary mode during the drug injection period. TRS-BRS significantly increased during phenylephrine and decreased under nitroprusside. CONCLUSIONS/SIGNIFICANCE: The TRS analysis provides a reliable, non-invasive assessment of human BRS not only under static steady state conditions, but also during pharmacological perturbation of the cardiovascular system
    • …
    corecore