4 research outputs found

    Towards a Universal Method for the Stable and Clean Functionalization of Inert Perfluoropolymer Nanoparticles : Exploiting Photopolymerizable Amphiphilic Diacetylenes

    Get PDF
    Highly fluorinated materials are being widely investigated due to a number of peculiar properties, which are potentially useful for various applications, including use as lubricants, anti-adhesive films, and substitutes for biological fluids for biomedical utilization. However, at present such potential is still poorly exploited. One of the major drawbacks that hampers the rapid development of nanoscale fluoro-hybrid devices is the remarkable inertness of perfluoropolymeric materials that lack reactive functionalities, as they do not offer any functional groups that can be employed to covalently anchor organic molecules on their surface. In this paper, a convenient method for the stable biofunctionalization of strongly unreactive perfluoropolymer nanoparticles (PnPs) is reported. PnPs are easily coated with newly synthesized asymmetric diacetylenic monomer compounds (ADMs), thanks to PnP's high propensity to interact with hydrophobic moieties. Once monomerically adsorbed onto PnPs, such suitably designed ADMs enable the formation of a robust polymeric shell around the perfluoroelastomer core via a clean UV-promoted localized photopolymerization. Given the peculiar optical characteristics of PnPs, the coating of the particles can be monitored step by step using light scattering, which also allows estimation of the fraction of reacted monomers by competitive adsorption with smaller particles. The potential of this method for the biofunctionalization of PnPs is demonstrated with representative proteins and carbohydrates. Among them, the extension to avidin-biotin technology may broaden the scope and applicability of this strategy to potentially a large number of molecules of biomedical interest. Making the unreactive reactive: A smart method for the biofunctionalization of strongly inert perfluoropolymer nanoparticles (PnPs) is presented, using a stable coating with novel diacetylenic compounds followed by clean UV photopolymerization to generate reactive functionalities on the PnP surface. This method further allows fine tuning of the amount of conjugated biomolecules, which can be sensitively and straightforwardly quantified

    CD271 activation prevents low to high-risk progression of cutaneous squamous cell carcinoma and improves therapy outcomes

    Get PDF
    Background: Cutaneous squamous cell carcinoma (cSCC) is the second most prevalent form of skin cancer, showing a rapid increasing incidence worldwide. Although most cSCC can be cured by surgery, a sizeable number of cases are diagnosed at advanced stages, with local invasion and distant metastatic lesions. In the skin, neurotrophins (NTs) and their receptors (CD271 and Trk) form a complex network regulating epidermal homeostasis. Recently, several works suggested a significant implication of NT receptors in cancer. However, CD271 functions in epithelial tumors are controversial and its precise role in cSCC is still to be defined. Methods: Spheroids from cSCC patients with low-risk (In situ or Well-Differentiated cSCC) or high-risk tumors (Moderately/Poorly Differentiated cSCC), were established to explore histological features, proliferation, invasion abilities, and molecular pathways modulated in response to CD271 overexpression or activation in vitro. The effect of CD271 activities on the response to therapeutics was also investigated. The impact on the metastatic process and inflammation was explored in vivo and in vitro, by using zebrafish xenograft and 2D/3D models. Results: Our data proved that CD271 is upregulated in Well-Differentiated tumors as compared to the more aggressive Moderately/Poorly Differentiated cSCC, both in vivo and in vitro. We demonstrated that CD271 activities reduce proliferation and malignancy marker expression in patient-derived cSCC spheroids at each tumor grade, by increasing neoplastic cell differentiation. CD271 overexpression significantly increases cSCC spheroid mass density, while it reduces their weight and diameter, and promotes a major fold-enrichment in differentiation and keratinization genes. Moreover, both CD271 overexpression and activation decrease cSCC cell invasiveness in vitro. A significant inhibition of the metastatic process by CD271 was observed in a newly established zebrafish cSCC model. We found that the recruitment of leucocytes by CD271-overexpressing cells directly correlates with tumor killing and this finding was further highlighted by monocyte infiltration in a THP-1-SCC13 3D model. Finally, CD271 activity synergizes with Trk receptor inhibition, by reducing spheroid viability, and significantly improves the outcome of photodynamic therapy (PTD) or chemotherapy in spheroids and zebrafish. Conclusion: Our study provides evidence that CD271 could prevent the switch between low to high-risk cSCC tumors. Because CD271 contributes to maintaining active differentiative paths and favors the response to therapies, it might be a promising target for future pharmaceutical development

    Raman Spectroscopy Reveals That Biochemical Composition of Breast Microcalcifications Correlates with Histopathologic Features

    No full text
    Breast microcalcifications are a common mammographic finding. Microcalcifications are considered suspicious signs of breast cancer and a breast biopsy is required, however, cancer is diagnosed in only a few patients. Reducing unnecessary biopsies and rapid characterization of breast microcalcifications are unmet clinical needs. In this study, 473 microcalcifications detected on breast biopsy specimens from 56 patients were characterized entirely by Raman mapping and confirmed by X-ray scattering. Microcalcifications from malignant samples were generally more homogeneous, more crystalline, and characterized by a less substituted crystal lattice compared with benign samples. There were significant differences in Raman features corresponding to the phosphate and carbonate bands between the benign and malignant groups. In addition to the heterogeneous composition, the presence of whitlockite specifically emerged as marker of benignity in benign microcalcifications. The whole Raman signature of each microcalcification was then used to build a classification model that distinguishes microcalcifications according to their overall biochemical composition. After validation, microcalcifications found in benign and malignant samples were correctly recognized with 93.5% sensitivity and 80.6% specificity. Finally, microcalcifications identified in malignant biopsies, but located outside the lesion, reported malignant features in 65% of in situ and 98% of invasive cancer cases, respectively, suggesting that the local microenvironment influences microcalcification features. This study confirms that the composition and structural features of microcalcifications correlate with breast pathology and indicates new diagnostic potentialities based on microcalcifications assessment

    Comparability of Raman Spectroscopic Configurations: A Large Scale Cross-Laboratory Study

    Get PDF
    International audienceThe variable configuration of Raman spectroscopic platforms is one of the major obstacles in establishing Raman spectroscopy as a valuable physicochemical method within real-world scenarios such as clinical diagnostics. For such real world applications like diagnostic classification, the models should ideally be usable to predict data from different setups. Whether it is done by training a rugged model with data from many setups or by a primary-replica strategy where models are developed on a ‘primary’ setup and the test data are generated on ‘replicate’ setups, this is only possible if the Raman spectra from different setups are consistent, reproducible, and comparable. However, Raman spectra can be highly sensitive to the measurement conditions, and they change from setup to setup even if the same samples are measured. Although increasingly recognized as an issue, the dependence of the Raman spectra on the instrumental configuration is far from being fully understood and great effort is needed to address the resulting spectral variations and to correct for them. To make the severity of the situation clear, we present a round robin experiment investigating the comparability of 35 Raman spectroscopic devices with different configurations in 15 institutes within seven European countries from the COST (European Cooperation in Science and Technology) action Raman4clinics. The experiment was developed in a fashion that allows various instrumental configurations ranging from highly confocal setups to fibre-optic based systems with different excitation wavelengths. We illustrate the spectral variations caused by the instrumental configurations from the perspectives of peak shifts, intensity variations, peak widths, and noise levels. We conclude this contribution with recommendations that may help to improve the inter-laboratory studies
    corecore