165 research outputs found

    Major Element Chemical Heterogeneity in Geo2 Olivine Micro-Beam Reference Material: A Spatial Approach to Quantifying Heterogeneity in Primary Reference Materials

    Get PDF
    A 270 spot-analysis study was conducted across a large (ca. 1200 μm x 1200 μm) chip of Geo2 olivine from a commercially available GEO Mk2 block (P and H Developments 2016) which revealed a 8.7% relative range in FeO abundance. Interleaved and overlapping grids of different resolutions were measured sequentially to prove spatial patterns are not due to drift or other external sources of error. Results were mapped and interpolated using commercially available geographical information system software, such that composition could be predicted according to location with high accuracy. The simple, systematic zonation pattern observed demonstrates that useful-sized regions of acceptable homogeneity do exist for some elements. This knowledge allows a user to target individual regions of a characterised chip for use as distinct measurement standards. As analysis times decrease and datasets grow, this approach may maximise laboratory efficiency by characterising large chips and extending time between standard block re-polish and coating, particularly in those cases where the avoidance of prior beam damage is a key concern

    Enabling three-dimensional densitometric measurements using laboratory source X-ray micro-computed tomography

    Get PDF
    We present new software allowing significantly improved quantitative mapping of the three-dimensional density distribution of objects using laboratory source polychromatic X-rays via a beam characterisation approach (c.f. filtering or comparison to phantoms). One key advantage is that a precise representation of the specimen material is not required. The method exploits well-established, widely available, non-destructive and increasingly accessible laboratory-source X-ray tomography. Beam characterisation is performed in two stages: (1) projection data are collected through a range of known materials utilising a novel hardware design integrated into the rotation stage; and (2) a Python code optimises a spectral response model of the system. We provide hardware designs for use with a rotation stage able to be tilted, yet the concept is easily adaptable to virtually any laboratory system and sample, and implicitly corrects the image artefact known as beam hardening

    High-energy, high-resolution, fly-scan X-ray phase tomography

    Get PDF
    High energy X-ray phase contrast tomography is tremendously beneficial to the study of thick and dense materials with poor attenuation contrast. Recently, the X-ray speckle-based imaging technique has attracted widespread interest because multimodal contrast images can now be retrieved simultaneously using an inexpensive wavefront modulator and a less stringent experimental setup. However, it is time-consuming to perform high resolution phase tomography with the conventional step-scan mode because the accumulated time overhead severely limits the speed of data acquisition for each projection. Although phase information can be extracted from a single speckle image, the spatial resolution is deteriorated due to the use of a large correlation window to track the speckle displacement. Here we report a fast data acquisition strategy utilising a fly-scan mode for near field X-ray speckle-based phase tomography. Compared to the existing step-scan scheme, the data acquisition time can be significantly reduced by more than one order of magnitude without compromising spatial resolution. Furthermore, we have extended the proposed speckle-based fly-scan phase tomography into the previously challenging high X-ray energy region (120 keV). This development opens up opportunities for a wide range of applications where exposure time and radiation dose are critical

    High-energy, high-resolution, fly-scan X-ray phase tomography

    Get PDF
    High energy X-ray phase contrast tomography is tremendously beneficial to the study of thick and dense materials with poor attenuation contrast. Recently, the X-ray speckle-based imaging technique has attracted widespread interest because multimodal contrast images can now be retrieved simultaneously using an inexpensive wavefront modulator and a less stringent experimental setup. However, it is time-consuming to perform high resolution phase tomography with the conventional step-scan mode because the accumulated time overhead severely limits the speed of data acquisition for each projection. Although phase information can be extracted from a single speckle image, the spatial resolution is deteriorated due to the use of a large correlation window to track the speckle displacement. Here we report a fast data acquisition strategy utilising a fly-scan mode for near field X-ray speckle-based phase tomography. Compared to the existing step-scan scheme, the data acquisition time can be significantly reduced by more than one order of magnitude without compromising spatial resolution. Furthermore, we have extended the proposed speckle-based fly-scan phase tomography into the previously challenging high X-ray energy region (120 keV). This development opens up opportunities for a wide range of applications where exposure time and radiation dose are critical

    X-ray phase-contrast imaging with engineered porous materials over 50 keV

    Get PDF
    X-ray phase-contrast imaging can substantially enhance image contrast for weakly absorbing samples. The fabrication of dedicated optics remains a major barrier, especially in high-energy regions (i.e. over 50 keV). Here, the authors perform X-ray phase-contrast imaging by using engineered porous materials as random absorption masks, which provides an alternative solution to extend X-ray phase-contrast imaging into previously challenging higher energy regions. The authors have measured various samples to demonstrate the feasibility of the proposed engineering materials. This technique could potentially be useful for studying samples across a wide range of applications and disciplines

    Getting into hot water:sick guppies frequent warmer thermal conditions

    Get PDF
    Ectotherms depend on the environmental temperature for thermoregulation and exploit thermal regimes that optimise physiological functioning. They may also frequent warmer conditions to up-regulate their immune response against parasite infection and/or impede parasite development. This adaptive response, known as ‘behavioural fever’, has been documented in various taxa including insects, reptiles and fish, but only in response to endoparasite infections. Here, a choice chamber experiment was used to investigate the thermal preferences of a tropical freshwater fish, the Trinidadian guppy (Poecilia reticulata), when infected with a common helminth ectoparasite Gyrodactylus turnbulli, in female-only and mixed-sex shoals. The temperature tolerance of G. turnbulli was also investigated by monitoring parasite population trajectories on guppies maintained at a continuous 18, 24 or 32 °C. Regardless of shoal composition, infected fish frequented the 32 °C choice chamber more often than when uninfected, significantly increasing their mean temperature preference. Parasites maintained continuously at 32 °C decreased to extinction within 3 days, whereas mean parasite abundance increased on hosts incubated at 18 and 24 °C. We show for the first time that gyrodactylid-infected fish have a preference for warmer waters and speculate that sick fish exploit the upper thermal tolerances of their parasites to self medicate

    Surface radio-mineralisation mediates chelate-free radiolabelling of iron oxide nanoparticles

    Get PDF
    We introduce the concept of surface radio-mineralisation (SRM) to describe the chelate-free radiolabelling of iron-oxide and ferrite nanoparticles. We demonstrate the effectiveness of SRM with both 111In and 89Zr for bare, polymer-matrix multicore, and surface-functionalised magnetite/maghemite nanoparticles; and for bare Y3Fe5O12 nanoparticles. By analogy with geological mineralisation (the hydrothermal deposition of metals as minerals in ore bodies or lodes) we demonstrate that the heat-induced and aqueous SRM process deposits radiometal-oxides onto the nanoparticle or core surfaces, passing through the matrix or coating if present, without changing the size, structure, or magnetic properties of the nanoparticle or core. We show in a mouse model followed over 7 days that the SRM is sufficient to allow quantitative, non-invasive, prolonged, whole-body localisation of injected nanoparticles with nuclear imaging

    Broad environmental tolerance of native root- nodule bacteria of Biserrula pelecinus indicate potential for soil fertility restoration

    Get PDF
    Background: Biserrula pelecinus is an annual legume native to the Mediterranean basin, found in pastureland, alone or in association with other legumes (Leguminosae) and grasses (Poaceae). It has been used in revegetation programmes of mining wastes showing phytoremediation potentials and thus becoming potentially highly attractive for plant ecology and restoration management of natural ecosystems. Aims: To characterise native root-nodule bacteria isolated from B. pelecinus from the Iberian Peninsula, and to select suitable N fixers for field-application and soil rehabilitation. Methods: Strains were isolated and molecularly identified by 16S rRNA amplification and sequencing. Strains were phenotypically characterised in different abiotic conditions (acidity, salinity and heavy metals) and tested for their ability to fix atmospheric N2. The most suitable N fixers were applied in greenhouse experiments with B. pelecinus under different fertilization levels to assess their tolerance to fertilized and polluted soils, commonly encountered in restoration projects. Results: B. pelecinus root-nodule isolates tolerated pH from 4.5 to 9.5 grew in saline conditions (2.5% of NaCl), and tolerated 50 μM of Al3+ and Mn2+. Three isolates efficient in N2 fixation, relative to the reference Mesorhizobium strain, were considered excellent candidates for the amelioration of nutrient poor sites. Conclusions: These results provide valuable information for the potential use in soil restoration of B. pelecinus in a wide- range of conditions, exploiting the natural variability of its root-nodule bacteria

    Biomagnetic of Apatite-Coated Cobalt Ferrite: A Core–Shell Particle for Protein Adsorption and pH-Controlled Release

    Get PDF
    Magnetic nanoparticle composite with a cobalt ferrite (CoFe2O4, (CF)) core and an apatite (Ap) coating was synthesized using a biomineralization process in which a modified simulated body fluid (1.5SBF) solution is the source of the calcium phosphate for the apatite formation. The core–shell structure formed after the citric acid–stabilized cobalt ferrite (CFCA) particles were incubated in the 1.5 SBF solution for 1 week. The mean particle size of CFCA-Ap is about 750 nm. A saturation magnetization of 15.56 emug-1 and a coercivity of 1808.5 Oe were observed for the CFCA-Ap obtained. Bovine serum albumin (BSA) was used as the model protein to study the adsorption and release of the proteins by the CFCA-Ap particles. The protein adsorption by the CFCA-Ap particles followed a more typical Freundlich than Langmuir adsorption isotherm. The BSA release as a function of time became less rapid as the CFCA-Ap particles were immersed in higher pH solution, thus indicating that the BSA release is dependent on the local pH
    • …
    corecore