32 research outputs found

    Low Background Micromegas in CAST

    Get PDF
    Solar axions could be converted into x-rays inside the strong magnetic field of an axion helioscope, triggering the detection of this elusive particle. Low background x-ray detectors are an essential component for the sensitivity of these searches. We report on the latest developments of the Micromegas detectors for the CERN Axion Solar Telescope (CAST), including technological pathfinder activities for the future International Axion Observatory (IAXO). The use of low background techniques and the application of discrimination algorithms based on the high granularity of the readout have led to background levels below 10−6^{-6} counts/keV/cm2^2/s, more than a factor 100 lower than the first generation of Micromegas detectors. The best levels achieved at the Canfranc Underground Laboratory (LSC) are as low as 10−7^{-7} counts/keV/cm2^2/s, showing good prospects for the application of this technology in IAXO. The current background model, based on underground and surface measurements, is presented, as well as the strategies to further reduce the background level. Finally, we will describe the R&D paths to achieve sub-keV energy thresholds, which could broaden the physics case of axion helioscopes.Comment: 6 pages, 3 figures, Large TPC Conference 2014, Pari

    PSR J1119-6127 and the X-ray Emission from High Magnetic Field Radio Pulsars

    Get PDF
    The existence of radio pulsars having inferred magnetic elds in the magnetar regime suggests that possible transition objects could be found in the radio pulsar population. The discovery of such an object would contribute greatly to our understanding of neutron star physics. Here we report on unusual X-ray emission detected from the radio pulsar PSR J1119-6127 using XMM-Newton. The pulsar has a characteristic age of 1,700 yrs and inferred surface dipole magnetic eld strength of 4.1x10^13 G. In the 0.5-2.0 keV range, the emission shows a single, narrow pulse with an unusually high pulsed fraction of ~70%. No pulsations are detected in the 2.0-10.0 keV range, where we derive an upper limit at the 99% level for the pulsed fraction of 28%. The pulsed emission is well described by a thermal blackbody model with a high temperature of 2.4x10^6 K. While no unambiguous signature of magnetar-like emission has been found in high-magnetic-eld radio pulsars, the X-ray characteristics of PSR J1119-6127 require alternate models from those of conventional thermal emission from neutron stars. In addition, PSR J1119-6127 is now the radio pulsar with the smallest characteristic age from which thermal X-ray emission has been detected

    First results on the search for chameleons with the KWISP detector at CAST

    Get PDF
    We report on a first measurement with a sensitive opto-mechanical force sensor designed for the direct detection of coupling of real chameleons to matter. These dark energy candidates could be produced in the Sun and stream unimpeded to Earth. The KWISP detector installed on the CAST axion search experiment at CERN looks for tiny displacements of a thin membrane caused by the mechanical effect of solar chameleons. The displacements are detected by a Michelson interferometer with a homodyne readout scheme. The sensor benefits from the focusing action of the ABRIXAS X-ray telescope installed at CAST, which increases the chameleon flux on the membrane. A mechanical chopper placed between the telescope output and the detector modulates the incoming chameleon stream. We present the results of the solar chameleon measurements taken at CAST in July 2017, setting an upper bound on the force acting on the membrane of 80pN at 95% confidence level. The detector is sensitive for direct coupling to matter 104 = ßm = 108, where the coupling to photons is locally bound to ß¿ = 1011

    First results of the CAST-RADES haloscope search for axions at 34.67 ”eV

    Get PDF
    We present results of the Relic Axion Dark-Matter Exploratory Setup (RADES), a detector which is part of the CERN Axion Solar Telescope (CAST), searching for axion dark matter in the 34.67 ”eV mass range. A radio frequency cavity consisting of 5 sub-cavities coupled by inductive irises took physics data inside the CAST dipole magnet for the first time using this filter-like haloscope geometry. An exclusion limit with a 95% credibility level on the axion-photon coupling constant of gaÂż Âż 4 × 10-13 GeV-1 over a mass range of 34.6738 ”eV < ma< 34.6771 ”eV is set. This constitutes a significant improvement over the current strongest limit set by CAST at this mass and is at the same time one of the most sensitive direct searches for an axion dark matter candidate above the mass of 25 ”eV. The results also demonstrate the feasibility of exploring a wider mass range around the value probed by CAST-RADES in this work using similar coherent resonant cavities. © 2021, The Author(s)

    Improved search for solar chameleons with a GridPix detector at CAST

    Get PDF
    We report on a new search for solar chameleons with the CERN Axion Solar Telescope (CAST). A GridPix detector was used to search for soft X-ray photons in the energy range from 200 eV to 10 keV from converted solar chameleons. No significant excess over the expected background has been observed in the data taken in 2014 and 2015. We set an improved limit on the chameleon photon coupling, beta(gamma) less than or similar to 5.7 x 10(10) for 1 < beta(m) < 10(6) at 95% C.L. improving our previous results by a factor two and for the first time reaching sensitivity below the solar luminosity bound for tachocline magnetic fields up to 12.5 T

    High-time Resolution Astrophysics and Pulsars

    Full text link
    The discovery of pulsars in 1968 heralded an era where the temporal characteristics of detectors had to be reassessed. Up to this point detector integration times would normally be measured in minutes rather seconds and definitely not on sub-second time scales. At the start of the 21st century pulsar observations are still pushing the limits of detector telescope capabilities. Flux variations on times scales less than 1 nsec have been observed during giant radio pulses. Pulsar studies over the next 10 to 20 years will require instruments with time resolutions down to microseconds and below, high-quantum quantum efficiency, reasonable energy resolution and sensitive to circular and linear polarisation of stochastic signals. This chapter is review of temporally resolved optical observations of pulsars. It concludes with estimates of the observability of pulsars with both existing telescopes and into the ELT era.Comment: Review; 21 pages, 5 figures, 86 references. Book chapter to appear in: D.Phelan, O.Ryan & A.Shearer, eds.: High Time Resolution Astrophysics (Astrophysics and Space Science Library, Springer, 2007). The original publication will be available at http://www.springerlink.co

    Probing eV-scale axions with CAST

    Get PDF
    We have searched for solar axions or other pseudoscalar particles that couple to two photons by using the CERN Axion Solar Telescope (CAST) setup. Whereas we previously have reported results from CAST with evacuated magnet bores (Phase I), setting limits on lower mass axions, here we report results from CAST where the magnet bores were filled with \hefour gas (Phase II) of variable pressure. The introduction of gas generated a refractive photon mass mÎłm_\gamma, thereby achieving the maximum possible conversion rate for those axion masses \ma that match mÎłm_\gamma. With 160 different pressure settings we have scanned \ma up to about 0.4 eV, taking approximately 2 h of data for each setting. From the absence of excess X-rays when the magnet was pointing to the Sun, we set a typical upper limit on the axion-photon coupling of \gag\lesssim 2.17\times 10^{-10} {\rm GeV}^{-1} at 95% CL for \ma \lesssim 0.4 eV, the exact result depending on the pressure setting. The excluded parameter range covers realistic axion models with a Peccei-Quinn scale in the neighborhood of fa∌107f_{\rm a}\sim10^{7} GeV. Currently in the second part of CAST Phase II, we are searching for axions with masses up to about 1.2 eV using \hethree as a buffer gas.Comment: 18 pages, 7 figures. Revised version of the paper after referee's comments. Main changes on the gas sectio

    The Next Generation of Axion Helioscopes: The International Axion Observatory (IAXO)

    Get PDF
    The International Axion Observatory (IAXO) is a proposed 4th-generation axion helioscope with the primary physics research goal to search for solar axions via their Primakoff conversion into photons of 1 \u2013 10 keV energies in a strong magnetic field. IAXO will achieve a sensitivity to the axion-photon coupling ga\u3b3 down to a few 710 1212 GeV 121 for a wide range of axion masses up to 3c 0.25 eV. This is an improvement over the currently best (3rd generation) axion helioscope, the CERN Axion Solar Telescope (CAST), of about 5 orders of magnitude in signal strength, corresponding to a factor 3c 20 in the axion photon coupling. IAXO's sensitivity relies on the construction of a large superconducting 8-coil toroidal magnet of 20 m length optimized for axion research. Each of the eight 60 cm diameter magnet bores is equipped with x-ray optics focusing the signal photons into 3c 0.2 cm2 spots that are imaged by very low background x-ray detectors. The magnet will be built into a structure with elevation and azimuth drives that will allow solar tracking for 12 hours each day. This contribution is a summary of our papers [1], [2] and [3] and we refer to these for further details

    The IAXO Helioscope

    Get PDF
    The IAXO (International Axion Experiment) is a fourth generation helioscope with a sensitivity, in terms of detectable signal counts, at least 104 better than CAST phase-I, resulting in sensitivity on gaÂż one order of magnitude better. To achieve this performance IAXO will count on a 8-coil toroidal magnet with 60 cm diameter bores and equipped with X-ray focusing optics into 0.20 cm2 spots coupled to ultra-low background Micromegas X-ray detectors. The magnet will be on a platform that will allow solar tracking for 12 hours per day. The next short term objectives are to prepare a Technical Design Report and to construct the first prototypes of the hardware main ingredients: demonstration coil, X-ray optics and low background detector while refining the physics case and studying the feasibility studies for Dark Matter axions
    corecore