45 research outputs found

    Very Wideband automated On-Wafer noise figure and Gain measurements At 50-110

    Get PDF
    On-wafer noise figure and insertion gain measurement set-ups have been developed over 50-110 GHz frequency range. Wafer scale noise figure and insertion gain measurements can be done in an automatic manner using PC controlled automated probe station and in-house written software. In narrow band measurements, large systematic errors may remain undiscovered. These errors are usually caused by reflections in the set-up, which are difficult to calibrate out. Wideband measurements are often the only method, which can efficiently reveal these errors. This aspect is increasingly important as frequency increases

    Objectively measured physical activity profile and cognition in Finnish elderly twins

    Get PDF
    Introduction We studied whether objectively measured physical activity (PA) and sedentary behavior (SB) are associated with cognition in Finnish elderly twins. Methods This cross-sectional study comprised twins born in Finland from 1940 to 1944 in the Older Finnish Twin Cohort (mean age, 72.9 years; 726 persons). From 2014 to 2016, cognition was assessed with a validated telephonic interview, whereas PA was measured with a waist-worn accelerometer. Results In between-family models, SB and light physical activity had significant linear associations with cognition after adjusting for age, sex, wearing time, education level, body mass index, and living condition (SB: β-estimate, −0.21 [95% confidence intervals, −0.42 to −0.003]; light physical activity: β-estimate, 0.30 [95% confidence intervals, 0.02–0.58]). In within-family models, there were no significant linear associations between objectively measured PA and cognition. Discussion Objectively measured light physical activity and SB are associated with cognition in Finnish twins in their seventies, but the associations were attributable to genetic and environmental selection.Peer reviewe

    Chronic diseases and objectively monitored physical activity profile among aged individuals - a cross-sectional twin cohort study

    Get PDF
    Introduction: High physical activity (PA) at old age indicates good functional capacity enabling independent living. We investigated how different disease conditions are associated with measured PA indicators in old women and men, and whether they recognize this association. Materials and methods: This cross-sectional twin cohort study in Finland comprised 779 individuals (276 complete twin pairs, including 117 monozygotic pairs), who participated in hip-worn accelerometer monitoring of PA and responded to questions on diseases and mobility limitations at mean age of 73 (range 71-75). Results: Of the participants, 23.2% reported having a disease restricting mobility. With sex and age in the regression model, the reported disease restricting mobility explained 11.8% of the variation in moderate-to-vigorous PA (MVPA) and 10.4% of the variation in daily steps. Adding stepwise other self-reported diseases and body mass index to the model increased the explanatory power for MVPA up to 18.5% and 25.5%, and for daily steps up to 16.0% and 20.7%, respectively. In the co-twin control analysis the PA differences were smaller in disease-discordant monozygotic than dizygotic pairs. Conclusions: Chronic disease conditions are associated with low PA, which individuals may not always recognize. Shared genetic factors may explain part of the associations.Key messages Among community-dwelling older men and women one-fourth of the variation in objectively measured moderate-to-vigorous physical activity is accounted for by age, sex, body mass index and self-reported diseases. Occurrence of chronic diseases is associated with low physical activity and individuals do not always recognize this. Healthcare professionals should pay attention to the low physical activity and mobility of individuals with chronic disease conditions before these result in limitations in independent living.Peer reviewe

    Chronic diseases and objectively monitored physical activity profile among aged individuals – a cross-sectional twin cohort study

    Get PDF
    Introduction: High physical activity (PA) at old age indicates good functional capacity enabling independent living. We investigated how different disease conditions are associated with measured PA indicators in old women and men, and whether they recognize this association.Materials and methods: This cross-sectional twin cohort study in Finland comprised 779 individuals (276 complete twin pairs, including 117 monozygotic pairs), who participated in hip-worn accelerometer monitoring of PA and responded to questions on diseases and mobility limitations at mean age of 73 (range 71–75).Results: Of the participants, 23.2% reported having a disease restricting mobility. With sex and age in the regression model, the reported disease restricting mobility explained 11.8% of the variation in moderate-to-vigorous PA (MVPA) and 10.4% of the variation in daily steps. Adding stepwise other self-reported diseases and body mass index to the model increased the explanatory power for MVPA up to 18.5% and 25.5%, and for daily steps up to 16.0% and 20.7%, respectively. In the co-twin control analysis the PA differences were smaller in disease-discordant monozygotic than dizygotic pairs.Conclusions: Chronic disease conditions are associated with low PA, which individuals may not always recognize. Shared genetic factors may explain part of the associations.</p

    Objectively measured physical activity profile and cognition in Finnish elderly twins

    Get PDF
    Introduction: We studied whether objectively measured physical activity (PA) and sedentary behavior (SB) are associated with cognition in Finnish elderly twins.Methods: This cross-sectional study comprised twins born in Finland from 1940 to 1944 in the Older Finnish Twin Cohort (mean age, 72.9 years; 726 persons). From 2014 to 2016, cognition was assessed with a validated telephonic interview, whereas PA was measured with a waist-worn accelerometer.Results: In between-family models, SB and light physical activity had significant linear associations with cognition after adjusting for age, sex, wearing time, education level, body mass index, and living condition (SB: β-estimate, −0.21 [95% confidence intervals, −0.42 to −0.003]; light physical activity: β-estimate, 0.30 [95% confidence intervals, 0.02–0.58]). In within-family models, there were no significant linear associations between objectively measured PA and cognition.Discussion: Objectively measured light physical activity and SB are associated with cognition in Finnish twins in their seventies, but the associations were attributable to genetic and environmental selection.</p

    Long-term leisure-time physical activity and other health habits as predictors of objectively monitored late-life physical activity - A 40-year twin study

    Get PDF
    Moderate-to-vigorous physical activity (MVPA) in old age is an important indicator of good health and functional capacity enabling independent living. In our prospective twin cohort study with 616 individuals we investigated whether long-term physical activity assessed three times, in 1975, 1982 and 1990 (mean age 48 years in 1990), and other self-reported health habits predict objectively measured MVPA measured with a hip-worn triaxial accelerometer (at least 10 hours per day for at least 4 days) 25 years later (mean age of 73 years). Low leisure-time physical activity at younger age, higher relative weight, smoking, low socioeconomic status, and health problems predicted low MVPA in old age in individual-based analyses (altogether explaining 20.3% of the variation in MVPA). However, quantitative trait modeling indicated that shared genetic factors explained 82% of the correlation between baseline and follow-up physical activity. Pairwise analyses within monozygotic twin pairs showed that only baseline smoking was a statistically significant predictor of later-life MVPA. The results imply that younger-age physical activity is associated with later-life MVPA, but shared genetic factors underlies this association. Of the other predictors mid-life smoking predicted less physical activity at older age independent of genetic factors

    Intravenously Administered Alphavirus Vector VA7 Eradicates Orthotopic Human Glioma Xenografts in Nude Mice

    Get PDF
    VA7 is a neurotropic alphavirus vector based on an attenuated strain of Semliki Forest virus. We have previously shown that VA7 exhibits oncolytic activity against human melanoma xenografts in immunodeficient mice. The purpose of this study was to determine if intravenously administered VA7 would be effective against human glioma.In vitro, U87, U251, and A172 human glioma cells were infected and killed by VA7-EGFP. In vivo, antiglioma activity of VA7 was tested in Balb/c nude mice using U87 cells stably expressing firefly luciferase in subcutaneous and orthotopic tumor models. Intravenously administered VA7-EGFP completely eradicated 100% of small and 50% of large subcutaneous U87Fluc tumors. A single intravenous injection of either VA7-EGFP or VA7 expressing Renilla luciferase (VA7-Rluc) into mice bearing orthotopic U87Fluc tumors caused a complete quenching of intracranial firefly bioluminescence and long-term survival in total 16 of 17 animals. In tumor-bearing mice injected with VA7-Rluc, transient intracranial and peripheral Renilla bioluminescence was observed. Virus was well tolerated and no damage to heart, liver, spleen, or brain was observed upon pathological assessment at three and ninety days post injection, despite detectable virus titers in these organs during the earlier time point.VA7 vector is apathogenic and can enter and destroy brain tumors in nude mice when administered systemically. This study warrants further elucidation of the mechanism of tumor destruction and attenuation of the VA7 virus

    A wideband automated measurement system for on-wafer noise parameter measurements at 50-75 GHZ

    Get PDF
    A wideband automated on-wafer noise parameter measurement system has been built. Using measurement system developed here, noise parameters of a chip device can be determined over entire 50-75 GHz range in an automated manner. As an example, measured noise parameters of an InP HEMT are shown over 50-75 GHz
    corecore