301 research outputs found

    The use of a non-absorbable membrane as an occlusive barrier for alveolar ridge preservation: A one year follow-up prospective cohort study

    Get PDF
    The aims of this study were to obtain preliminary data and test the clinical efficacy of a novel nonporous dense-polytetrafluoroethylene (d-PTFE) membrane (permamem®, botiss) in alveolar ridge preservation (ARP) procedures with a flapless approach. A traumatic extraction was performed in the premolar maxillary area, and a d-PTFE membrane was used to seal the alveolar cavity: no biomaterial was used to graft the socket and the membrane was left intentionally exposed and stabilized with sutures. The membrane was removed after four weeks and dental implants were placed four months after the procedure. The primary outcome variables were defined as the dimensional changes in the ridge width and height after four months. A total of 15 patients were enrolled in this study. The mean width of the alveolar cavity was 8.9 ± 1.1 mm immediately after tooth extraction, while four months later a mean reduction of 1.75 mm was experienced. A mean vertical reduction of 0.9 ± 0.42 mm on the buccal aspect and 0.6 ± 0.23 mm on the palatal aspect were recorded at implant placement. Within the limitations of this study, the d-PTFE membrane proved to be effective in alveolar ridge preservation, with the outcomes of the regeneration not affected by the complete exposure of this biomaterial

    Optimization of pixel size and propagation distance in X-ray phase-contrast virtual histology

    Get PDF
    X-ray phase-contrast coupled to high-spatial resolution imaging systems provides a high sensitivity for distinguishing soft tissue structures in small samples, thus being suited for X-ray virtual histology. Propagation-based phase-contrast tomography can deliver a considerable gain in signal-to-noise ratio (SNR) at small pixel sizes when it is combined to a suitable phase retrieval filter. We optimized acquisition parameters, namely the propagation distance and the pixel size, with the aim of providing adequate spatial resolution and sensitivity for virtual histology of breast surgery specimens, scanned with a phase-contrast microtomography (mu CT) system employing a commercial sCMOS detector at the SYRMEP beamline of the Italian synchrotron facility Elettra (Trieste, Italy). A pathological breast tissue sample was embedded in paraffin and imaged using a polychromatic synchrotron beam at an average energy of 24 keV. The high numerical optical aperture of the imaging system enabled to adjust the pixel size to 1, 2.5 and 4 mu m. The scans were acquired at five sample-to-detector distances: 4.5, 150, 250, 500 and 1000 mm. SNR was measured in an homogeneous region portion of the mu CT image for each combination of pixel size and propagation distance. Experimental results were compared to a theoretical model taking into account the actual point spread function of the employed imaging system. The measured gain of SNR associated with the application of the phase-retrieval matched the predictions for large Fresnel numbers (N-F > 2). For each pixel size, an optimal range of propagation distances was found. Optimal mu CT reconstructions were then compared with their respective histopatological images, showing an excellent visibility of relevant structures. The optimization performed in this study will allow to select the most appropriate geometrical configurations for future acquisitions of virtual histology images of different specimens via phase-contrast microtomography

    A Modified Rabbit Ulna Defect Model for Evaluating Periosteal Substitutes in Bone Engineering: A Pilot Study

    Get PDF
    The present work defines a modified critical size rabbit ulna defect model for bone regeneration in which a non-resorbable barrier membrane was used to separate the radius from the ulna to create a valid model for evaluation of tissue-engineered periosteal substitutes. Eight rabbits divided into two groups were used. Critical defects (15 mm) were made in the ulna completely eliminating periosteum. For group I, defects were filled with a nanohydroxyapatite poly(ester urethane) scaffold soaked in PBS and left as such (group Ia) or wrapped with a tissue-engineered periosteal substitute (group Ib). For group II, an expanded-polytetrafluoroethylene (e-PTFE) (GORE-TEX\uae) membrane was inserted around the radius then the defects received either scaffold alone (group IIa) or scaffold wrapped with periosteal substitute (group IIb). Animals were euthanized after 12\u201316 weeks, and bone regeneration was evaluated by radiography, computed microtomography (\ub5CT), and histology. In the first group, we observed formation of radio-ulnar synostosis irrespective of the treatment. This was completely eliminated upon placement of the e-PTFE (GORETEX\uae) membrane in the second group of animals. In conclusion, modification of the model using a non-resorbable e-PTFE membrane to isolate the ulna from the radius was a valuable addition allowing for objective evaluation of the tissue-engineered periosteal substitut

    Gadolinium tissue deposition in the periodontal ligament of mice with reduced renal function exposed to Gd-based contrast agents

    Get PDF
    Gadolinium deposition in tissue is linked to nephrogenic systemic fibrosis (NSF): a rare disorder occurring in patients with severe chronic kidney disease and associated with administration of Gd-based contrast agents (GBCAs) for Magnetic Resonance Imaging (MRI). It is suggested that the GBCAs prolonged permanence in blood in these patients may result in a Gd precipitation in peripheral or central organs, where it initiates a fibrotic process. In this study we investigated new sites of retention/precipitation of Gd in a mouse model of renal disease (5/6 nephrectomy) receiving two doses (closely after each other) of a linear GBCA. Two commercial GBCAs (Omniscan\uae and Magnevist\uae) were administered at doses slightly higher than those used in clinical practice (0.7 mmol/kg body weight, each). The animals were sacrificed one month after the last administration and the explanted organs (kidney, liver, femur, dorsal skin, teeth) were analysed by X-ray fluorescence (XRF) at two synchrotron facilities. The XRF analysis with a millimetre-sized beam at the SYRMEP beamline (Elettra, Italy) produced no detectable levels of Gd in the examined tissues, with the notable exception of the incisors of the nephrectomised mice. The XRF analyses at sub-micron resolution performed at ID21 (ESRF, France) allowed to clearly localize Gd in the periodontal ligaments of teeth both from Omniscan\uae and Magnevist\uae treated nephrectomised mice. The latter results were further confirmed by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The study prompts that prolonged permanence of GBCAs in blood may result in Gd retention in this particular muscular tissue, opening possibilities for diagnostic applications at this level when investigating Gd-related toxicities

    Анализ и пути улучшения финансового состояния предприятия (на примере ГЛХУ «Хойникский лесхоз»)

    Get PDF
    Lung imaging in mouse disease models is crucial for the assessment of the severity of airway disease but remains challenging due to the small size and the high porosity of the organ. Synchrotron inline free-propagation phase-contrast computed tomography (CT) with its intrinsic high soft-tissue contrast provides the necessary sensitivity and spatial resolution to analyse the mouse lung structure in great detail. Here, this technique has been applied in combination with single-distance phase retrieval to quantify alterations of the lung structure in experimental asthma mouse models of different severity. In order to mimic an in vivo situation as close as possible, the lungs were inflated with air at a constant physiological pressure. Entire mice were embedded in agarose gel and imaged using inline free-propagation phase-contrast CT at the SYRMEP beamline (Synchrotron Light Source, Elettra, Trieste, Italy). The quantification of the obtained phase-contrast CT data sets revealed an increasing lung soft-tissue content in mice correlating with the degree of the severity of experimental allergic airways disease. In this way, it was possible to successfully discriminate between healthy controls and mice with either mild or severe allergic airway disease. It is believed that this approach may have the potential to evaluate the efficacy of novel therapeutic strategies that target airway remodelling processes in asthma.Funding Agencies|German Research Foundation (Deutsche Forschungsgemeinschaft, DFG) [DU 1403/1-1]</p

    Perturbations of Spatially Closed Bianchi III Spacetimes

    Get PDF
    Motivated by the recent interest in dynamical properties of topologically nontrivial spacetimes, we study linear perturbations of spatially closed Bianchi III vacuum spacetimes, whose spatial topology is the direct product of a higher genus surface and the circle. We first develop necessary mode functions, vectors, and tensors, and then perform separations of (perturbation) variables. The perturbation equations decouple in a way that is similar to but a generalization of those of the Regge--Wheeler spherically symmetric case. We further achieve a decoupling of each set of perturbation equations into gauge-dependent and independent parts, by which we obtain wave equations for the gauge-invariant variables. We then discuss choices of gauge and stability properties. Details of the compactification of Bianchi III manifolds and spacetimes are presented in an appendix. In the other appendices we study scalar field and electromagnetic equations on the same background to compare asymptotic properties.Comment: 61 pages, 1 figure, final version with minor corrections, to appear in Class. Quant. Gravi

    X-ray based lung function measurement - a sensitive technique to quantify lung function in allergic airway inflammation mouse models

    No full text
    In mice, along with the assessment of eosinophils, lung function measurements, most commonly carried out by plethysmography, are essential to monitor the course of allergic airway inflammation, to examine therapy efficacy and to correlate animal with patient data. To date, plethysmography techniques either use intubation and/or restraining of the mice and are thus invasive, or are limited in their sensitivity. We present a novel unrestrained lung function method based on low-dose planar cinematic x-ray imaging (X-Ray Lung Function, XLF) and demonstrate its performance in monitoring OVA induced experimental allergic airway inflammation in mice and an improved assessment of the efficacy of the common treatment dexamethasone. We further show that XLF is more sensitive than unrestrained whole body plethysmography (UWBP) and that conventional broncho-alveolar lavage and histology provide only limited information of the efficacy of a treatment when compared to XLF. Our results highlight the fact that a multi-parametric imaging approach as delivered by XLF is needed to address the combined cellular, anatomical and functional effects that occur during the course of asthma and in response to therapy
    corecore