111 research outputs found

    Medición de presión intraocular con el tonómetro Proview®

    Get PDF
    Purpose: To evaluate a new ocular tonometer (Proview®) which functions by visualizing a phosphene after putting pressure on the upper eyelid. To ascertain its accuracy and reproducibility with respect to the Goldmann tonometer (GT). Methods: A study on both eyes of 110 non-selected patients was performed. One measurement with GT and three subsequent measurements with Proview® were taken by the same investigator. The number of failed attempts to visualize the phosphene was recorded. We evaluated each eye separately to observe the possible learning effect. Results: The intraocular pressure (IOP) mean with Proview® is 5 mm Hg higher than the GT (p0.05). Conclusions: The Proview® tonometer showed low accuracy and reproducibility in comparison with the GT. This tonometer requires a long learning process before phosphene visualization. The results demonstrated that this tonometer is not clinically useful, except in patients with serious corneal diseases which make measurement with GT very difficul

    Distrofia foveomacular viteliforme del adulto

    Get PDF
    Four cases of adult-onset foveomacular vitelliform dystrophy are shown. In two cases we were able to complete the exploration under optical coherence tomography. One of the patients developed spontaneous disappearance of the subfoveal deposit in her right eye along with an important decrease in her visual acuity. Discussion: Adult-onset foveomacular vitelliform dystrophy is characterized by yellowish round-shaped bilateral, lesions in the subfoveal area. Optical coherence tomography reveal the presence of a slightly elevated lesion wich affects the retinal pigment epithelium and the external layers of neurosensory retin

    Comparison of dynamic contour tonometry (Pascal®) with pneumotonometry and Goldmann tonometry

    Get PDF
    To compare the intraocular pressure measurements as defined by the Pascal tonometer, the Goldmann tonometer and the pneumotonometer. METHODS: This was an observational clinical study, which included two hundred and five randomly selected subjects recruited from the Ophthalmology Department. The intraocular pressure measurements were performed with each tonometry technique in a randomized order. RESULTS: The Pascal's intraocular pressure measurement was significantly higher than that measured by the other two tonometers (p<0.05). The quality data of Pascal was: optimum in 27.3% (56 of 205 patients), acceptable in 42% (86 of 205 patients) and unacceptable in 23.4% (48 of 205 patients). In 7.3% (15 of 205 patients) it was impossible to obtain any measurement using Pascal. A weak correlation coefficient between the Pascal and the Goldmann, and between Pascal and the pneumotonometer was found. The Bland-Altman method of measurement using these tonometers showed a high degree of discordance. CONCLUSION: As reported by others authors, the Pascal's intraocular pressure measurement is higher than that of the Goldmann tonometer. The measurement differs from 0.7 to 4.4 mmHg. In corneas with pathology, it is very difficult or even unacceptable to measure the intraocular pressure using the Pascal tonometer

    Amniotic membrane transplantation with fibrin glue as treatment of refractory conjunctivochalasis

    Get PDF
    Case report: A 63-year-old man with bilateral conjunctivochalasis presented with tearing, irritation, foreign body sensation and a delayed fluorescein clearance test. After no symptomatic improvement with topical treatment, surgery was carried out, with amniotic membrane transplantation and fibrin sealant. Discussion: Conjunctivochalasis is a frequent disorder that shares symptoms with dry eye syndrome. When there is no response to topical treatment, surgical treatment is needed. The surgical technique described by Tseng, and based on amniotic membrane transplantation without suture, resulted in a very useful response, due to less inflammation and a rapid resolution and improvement of symptom

    Distrofia macular anular benigna

    Get PDF
    Clinical cases: Two cases of benign concentric macular dystrophy are described. In one case, ophthalmologic examination, fluorescein angiogram and visual field measurement were performed. The presence of a juxtafoveal fibrosis in the other patient, indicate that choroidal neovascularization may be associated with this type of macular dystrophy. Discussion: Benign concentric macular dystrophy is an entity with well-defined ophthalmoscopic and angiographic characteristics. Usually the prognosis is good. Rarely, choroidal neovascularization can be associated with this macular dystroph

    Video-assisted mitral surgery through a micro-access: A safe and reliable reality in the current era

    Get PDF
    Background and aim of the study: Minimally invasive mitral valve surgery was introduced into clinical practice during the mid 1990s. The clinical benefits of the technique, namely a reduction of surgical trauma, increased patient comfort and shorter hospital stay, are achieved by using a video-assisted, mini-thoracotomy approach rather than a standard median sternotomy. Herein is described the authors' experience with video-assisted mitral surgery through a micro-access. Methods: Between September 2003 and September 2006, 100 patients (mean age 65.7 years; range: 16-84 years; 29 aged >75 years) underwent video-assisted port-access mitral valve surgery through a 4- to 6-cm anterior mini-thoracotomy. Mitral valve repair was carried out in 36 patients (36%) and mitral valve replacement (MVR) in 64 (64%) for degenerative (n = 54), rheumatic (n = 44), functional (n = 1) or infective disease (n = 1). Redo procedures were performed in 14 patients. Results: Peripheral extra-thoracic cardiopulmonary bypass (CPB) was used in all cases, and Endoclamp occlusion of the ascending aorta in 94%. The median intensive care unit and hospital stays were 20.0 +/- 30.8 h and 7.0 +/- 5.9 days, respectively. Hospital mortality was 4% (n = 4). No patient required conversion to sternotomy. Five patients (5%) underwent minimally invasive surgical revision for bleeding, and one patient (1%) had an early reoperation for MVR during the immediate postoperative course due to failure of a mitral valve repair. There were no perioperative myocardial infarctions, permanent strokes, major vascular complications, or peripheral ischemic events. Among the patients, 63% had no complications at all during the postoperative course, and no wound infections were observed. Conclusion: Video-assisted mitral surgery through a micro-access may be performed safely, at low risk of morbidity and mortality, and with results and quality standards similar to those reported for a sternotomy approach. Of note, older patients may be successfully treated using this technique

    Decolorization of Synthetic Textile Dyes by Fungal Endophytes Isolated from the Leaves of Philippine Mangrove (Avicennia marina)

    Get PDF
    Textile dyes in wastewater can be harmful pollutants when released into the environment without treatment. Biodegradation of textile dye effluents by different microbes, including fungi, has become popular as an alternative to physicochemical methods. The mangrove Avicennia marina is known to harbor endophytic fungi which have the potential to carry out dye degradation. Therefore, this study assessed the ability to decolorize synthetic dyes of endophytic fungi isolated from the leaves of A. marina. Of the nine fungal endophytes, Aspergillus niger, Syncephalastrum racemosum and Penicillium citrinum exhibited the highest mycelial growths in solid media, while all endophytes adsorbed Congo red. Through liquid decolorization assay, four isolates decolorized Congo red at greater than 89% decolorization rates. P. citrinum (55.45%), Mycelia sterilia (85.19%), A. flavus (44.91%) showed the highest decolorization rates of Methylene blue, Malachite green and Rhodamine B, respectively. The ligninolytic enzymes produced by the endophytic fungi, laccase exhibited the highest activity with values higher than the positive control

    Aceite de silicona para el tratamiento de la maculopatía hipotónica

    Get PDF
    Case report: We report a case of a man who developed hypotonic maculopathy after vitreoretinal surgery for anterior proliferative vitreoretinopathy. After an injection of intravitreal triamcinolone, the ocular pressure did not increase, therefore silicone oil was injected. After this, the visual acuity increased and the choroidal and retinal folds regressed. Discussion: Hypotonic maculopathy is a frustrating problem, often resulting in poor visual acuity. There are not many effective treatments. The injection of silicone oil could be an alternative to increase the intraocular pressure and re-establish the normal anatomy of the eye, improving the visual acuity in some patient

    Neuropatía óptica autoinmune recidivante bilateral en la infancia

    Get PDF
    Clinical case: A ten year-old girl, after a Yersinia gastroenteritis, developed an optic neuritis in the left eye. She was not treated and resulted ultimately in optic atrophy on the affected side. Six months later a similar episode occurred in the contralateral eye. On this occasion corticosteroid therapy was given. During this therapy the neuritis diminished; however the patient had three relapses, so it was decided to give her immunosuppressive treatment with azathioprine and continue this indefinitely. Discussion: After considering the differential diagnoses of bilateral recurrent optical neuritis in childhood, we concluded that it was most likely to have an autoimmune basis. After considering the benefits and risks of the long-term treatment, we believe immunosuppressive therapy is most useful in controlling the disease allowing corticosteroid therapy to be reduced (Arch Soc Esp Oftalmol 2006; 81: 607-610)

    Acrysof® toric intraocular lens implantation in cataract surgery

    Get PDF
    Aim: To assess the medium term outcomes of Acrysof® toric intraocular lens implantation in 54 patients (54 eyes). Methods: Uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), preoperative astigmatism, residual postoperative astigmatism, and global average and model-specific intraocular lens (IOL) rotation grade were analyzed. Results: At 2-months of follow-up,the mean UCVA was 0.83 (SD: 0.14) Snellen scale, with 73.9% of the patients ≥0.8, and 32.6% with 1.0. Mean BCVA achieved was 0.94 (SD: 0.10). Mean preoperatory astigmatism was –2.25 diopters (D) (SD: 0.78), and mean postoperative astigmatism was -0.32 D (SD: 0.56), with significant differences between both groups (p<0.001). Model-specific mean residual astigmatism was –0.1 D for T3, –0.27 D for T4 and –0.43 D for T5, without significant differences between the three models (p=0.483). Mean IOL-axis rotation grade was 3.87±3.25 degrees, with 91.6% of implanted lens within 10° of predicted axis. Discussion: T3, T4 and T5 Acrysof® Toric intraocular lenses can correct preoperative astigmatism with a high success rate in terms of UCVA, and residual postoperative astigmatism, with minimum IOL-rotation grade at 2 months follow-up period
    corecore