122 research outputs found

    Validity, Reliability, and Usefulness of My Jump 2 App for Measuring Vertical Jump in Primary School Children

    Get PDF
    There is a persistent need in sport science for developing a measuring tool that is affordable, portable, and easy to use. We aimed to examine the concurrent validity and test-retest reliability of the My Jump 2 app compared to a validated OptoJump instrument for measuring jump performance during the squat jump (SJ), countermovement jump (CMJ), and CMJ free arms (CMJAM) in primary school children. A total of 48 participants (11-14 years age), volunteered to participate in this research. The jumps were recorded with a validated OptoJump photoelectric cell system and a concurrent device (iPhone X through My Jump 2 app) at the same time. The participants repeated the testing procedure after two weeks to assess the reliability of the measurements (ICC). Systematic bias between sessions and tools was evaluated using the paired samples t-test and Bland and Altman analysis. High test-retest reliability (ICC > 0.89) was observed for all measures' in-between conditions. Very large correlations in the total sample were observed between the My Jump 2 app and OptoJump for SJ (r = 0.97, p = 0.001), CMJ (r = 0.97, p = 0.001), and CMJAM (r = 0.99, p = 0.001). Bland and Altman's plot depicting limits of agreement for the total sample between the OptoJump and My Jump 2 show that the majority of data points are within the 95% CIs. The results of this study suggest that My Jump 2 is a valid, reliable, and useful tool for measuring jump performance in primary school children

    Effects of Resistance Training With Constant, Inertial, and Combined Loads on Muscle Power and Strength Output

    Get PDF
    The aim of this study was to investigate the resistance-specific gains in muscle power and strength (1RM) following the training of maximum bench-press throws (BPT) against constant, inertial, and combined resistance. Forty-eight male participants (age 20.5 ± 2.0 years) were randomly assigned to the constant, inertial, combined resistance, or control group. Participants underwent 8 weeks of training of BPT against the loads that corresponded to the different effects of mass of 40 kg (∼50% of 1RM). The gains in average and maximum power, and 1RM were significant in all experimental groups (P 0.1). Relative gains in the average (26.3 ± 9.8%) and maximum power (25.2 ± 9.8%) were larger than that in the 1RM (mean 7.2 ± 6.9%; both P < 0.001). The gains in the average (F4, 66 = 6.0; P < 0.01) and maximum power (F4, 66 = 4.7; P < 0.01) were higher when tested against the training-specific resistance than when tested against the remaining two resistance types. Differences in 1RM among experimental groups were not significant (P = 0.092). The most important and rather novel finding of the study is that the training against the weight and inertial resistance, and their combination results in resistance-specific gains in muscle power, although the overall gains muscle strength and power remain comparable across the training protocols

    High-energy-resolution grazing emission X-ray fluorescence applied to the characterization of thin Al films on Si

    Get PDF
    The grazing emission X-ray fluorescence (GEXRF) technique was applied to the analysis of different Al films, with nominal thicknesses in the range of 1 nm to 150 nm, on Si wafers. In GEXRF the sample volume from which the fluorescence intensity is detected is restricted to a near-surface region whose thickness can be tuned by varying the observation angle. This is possible because of the refraction of the fluorescence X-rays and the quite long emission paths within the probed sample. By recording the X-ray fluorescence signal for different shallow emission angles, defined relatively to the flat, smooth sample surface, the deposited Al surface layers of the different samples could be well characterized in terms of layer thickness, layer density, oxidation and surface roughness. The advantages offered by synchrotron radiation and the employed wavelength-dispersive detection setup were profited from. The GEXRF results retrieved were confirmed by complementary measurements. The experimental setup, the principles and advantages of GEXRF and the analysis of the recorded angular intensity profiles will be discussed in details

    Radiative recombination of bare Bi83+: Experiment versus theory

    Get PDF
    Electron-ion recombination of completely stripped Bi83+ was investigated at the Experimental Storage Ring (ESR) of the GSI in Darmstadt. It was the first experiment of this kind with a bare ion heavier than argon. Absolute recombination rate coefficients have been measured for relative energies between ions and electrons from 0 up to about 125 eV. In the energy range from 15 meV to 125 eV a very good agreement is found between the experimental result and theory for radiative recombination (RR). However, below 15 meV the experimental rate increasingly exceeds the RR calculation and at Erel = 0 eV it is a factor of 5.2 above the expected value. For further investigation of this enhancement phenomenon the electron density in the interaction region was set to 1.6E6/cm3, 3.2E6/cm3 and 4.7E6/cm3. This variation had no significant influence on the recombination rate. An additional variation of the magnetic guiding field of the electrons from 70 mT to 150 mT in steps of 1 mT resulted in periodic oscillations of the rate which are accompanied by considerable changes of the transverse electron temperature.Comment: 12 pages, 14 figures, to be published in Phys. Rev. A, see also http://www.gsi.de/ap/ and http://www.strz.uni-giessen.de/~k

    Grazing angle X-ray fluorescence from periodic structures on silicon and silica surfaces

    Get PDF
    Various 3-dimensional nano-scaled periodic structures with different configurations and periods deposited on the surface of silicon and silica substrates were investigated by means of the grazing incidence and grazing emission X-ray fluorescence techniques. Apart from the characteristics which are typical for particle- and layer-like samples, the measured angular intensity profiles show additional periodicity-related features. The latter could be explained by a novel theoretical approach based on simple geometrical optics (GO) considerations. The new GO-based calculations were found to yield results in good agreement with experiment, also in cases where other theoretical approaches are not valid, e.g., periodic particle distributions with an increased surface coverage

    X-ray two-photon absorption with high fluence XFEL pulses

    Get PDF
    We report on nonlinear interaction of solid Fe with intense femtosecond hard x-ray free-electron laser (XFEL) pulses. The experiment was performed at the CXI end- station of the Linac Coherent Light Source (LCLS) by means of high- resolution x-ray emission spectroscopy. The focused x-ray beam provided extreme fluence of ~10⁵ photons/Ų. Two-photon absorption leading to K-shell hollow atom formation and to single K-shell ionization of solid Fe was investigated

    An Infant Formula with Partially Hydrolyzed Whey Protein Supports Adequate Growth and Is Safe and Well-Tolerated in Healthy, Term Infants: A Randomized, Double-Blind, Equivalence Trial

    Get PDF
    The current study evaluates the safety and tolerance of a partially hydrolyzed whey protein-based infant formula (PHF) versus an in intact cow's milk protein formula (IPF). Breastfed infants were included as a reference group. In a multi-country, multicenter, randomized, double-blinded, controlled clinical trial, infants whose mothers intended to fully formula feed were randomized to PHF (n= 134) or IPF (n= 134) from <= 14 days to 17 weeks of age. The equivalence analysis of weight gain per day within margins of +/-3 g/d (primary outcome), the recorded adverse events, growth and gastro-intestinal tolerance parameters were considered for the safety evaluation. Equivalence of weight gain per day from enrolment until 17 weeks of age was demonstrated in the PHF group compared to the IPF group (difference in means -1.2 g/d; 90% CI (-2.42; 0.02)), with estimated means (SE) of 30.2 (0.5) g/d and 31.4 (0.5) g/d, respectively. No significant differences in growth outcomes, the number, severity or type of (serious) adverse events and tolerance outcomes, were observed between the two formula groups. A partially hydrolyzed whey protein-based infant formula supports adequate infant growth, with a daily weight gain equivalent to a standard intact protein-based formula; it is also safe for use and well-tolerated in healthy term infants

    Application of the high-resolution grazing-emission x-ray fluorescence method for impurities control in semiconductor nanotechnology

    Get PDF
    We report on the application of synchrotron radiation based high-resolution grazing-emission x-ray fluorescence (GEXRF) method to measure low-level impurities on silicon wafers. The presented high-resolution GEXRF technique leads to direct detection limits of about 10¹²  atoms/cm². The latter can be presumably further improved down to 10⁷  atoms/cm² by combining the synchrotron radiation-based GEXRF method with the vapor phase decomposition preconcentration technique. The capability of the high-resolution GEXRF method to perform surface-sensitive elemental mappings with a lateral resolution of several tens of micrometers was probed
    corecore