7,273 research outputs found

    High-efficiency crystalline silicon technology development

    Get PDF
    The rationale for pursuing high efficiency crystalline silicon technology research is discussed. Photovoltaic energy systems are reviewed as to their cost effectiveness and their competitiveness with other energy systems. The parameters of energy system life are listed and briefly reviewed

    Radio Pulse Properties of the Millisecond Pulsar PSR J0437-4715. I. Observations at 20cm

    Get PDF
    We present a total of 48 minutes of observations of the nearby, bright millisecond pulsar PSR J0437-4715 taken at the Parkes radio observatory in Australia. The data were obtained at a central radio frequency of 1380 MHz using a high-speed tape recorder that permitted coherent Nyquist sampling of 50 MHz of bandwidth in each of two polarizations. Using the high time resolution available from this voltage recording technique, we have studied a variety of single-pulse properties, most for the first time in a millisecond pulsar. We find no evidence for "diffractive" quantization effects in the individual pulse arrival times or amplitudes as have been reported for this pulsar at lower radio frequency using coarser time resolution (Ables et al. 1997). Overall, we find that the single pulse properties of PSR J0437-4715 are similar to those of the common slow-rotating pulsars, even though this pulsar's magnetosphere and surface magnetic field are several orders of magnitude smaller than those of the general population. The pulsar radio emission mechanism must therefore be insensitive to these fundamental neutron star properties.Comment: 24 Postscript pages, 11 eps figures. Accepted for publication in the Astrophysical Journal. Abbreviated abstract follow

    Discovery of Pulsed X-ray Emission from the SMC Transient RX J0117.6-7330

    Get PDF
    We report on the detection of pulsed, broad-band, X-ray emission from the transient source RX J0117.6-7330. The pulse period of 22 seconds is detected by the ROSAT/PSPC instrument in a 1992 Sep 30 - Oct 2 observation and by the CGRO/BATSE instrument during the same epoch. Hard X-ray pulsations are detectable by BATSE for approximately 100 days surrounding the ROSAT observation (1992 Aug 28 - Dec 8). The total directly measured X-ray luminosity during the ROSAT observation is 1.0E38 (d/60 kpc)^2 ergs s-1. The pulse frequency increases rapidly during the outburst, with a peak spin-up rate of 1.2E-10 Hz s-1 and a total frequency change 1.8%. The pulsed percentage is 11.3% from 0.1-2.5 keV, increasing to at least 78% in the 20-70 keV band. These results establish RX J0117.6-7330 as a transient Be binary system.Comment: 17 pages, Latex, aasms, accepted for publication in ApJ Letter

    Rapid continuous chemical analysis of meat chicken shed emissions by SIFT–MS

    Get PDF
    Assessing and addressing odour impacts from poultry production is extremely difficult and subjective because the odorants involved and their dynamics over time and space are poorly understood. This knowledge gap is due, in part, to the lack of suitable analytical tools for measuring and monitoring odorants in the field. The emergence of Selected Ion Flow Tube – Mass Spectrometry (SIFT–MS) and similar instruments is changing that. These tools can rapidly quantify targeted odorants in ambient air in real time, even at very low concentrations. Such data is essential for developing better odour abatement strategies, assessment methods and odour dispersion models. This project trialled a SIFT–MS to determine its suitability for assessing the odorants in meat chicken shed emissions over time and space. This report details evaluations in New Zealand and Australia to determine the potential of SIFT–MS as a tool for the chicken meat industry, including odour measurement (as a proxy for dynamic olfactometry). The report is specifically targeted at those funding and conducting poultry odour research. It will be of interest to those involved with environmental odour monitoring and assessment in general. The high upfront cost of SIFT–MS will lead to potential users wanting compelling evidence that SIFT–MS will meet their needs before they invest in one

    Optimality Theory as a Framework for Lexical Acquisition

    Full text link
    This paper re-investigates a lexical acquisition system initially developed for French.We show that, interestingly, the architecture of the system reproduces and implements the main components of Optimality Theory. However, we formulate the hypothesis that some of its limitations are mainly due to a poor representation of the constraints used. Finally, we show how a better representation of the constraints used would yield better results

    Penning ionization of doped helium nanodroplets following EUV excitation

    Full text link
    Helium nanodroplets are widely used as a cold, weakly interacting matrix for spectroscopy of embedded species. In this work we excite or ionize doped He droplets using synchrotron radiation and study the effect onto the dopant atoms depending on their location inside the droplets (rare gases) or outside at the droplet surface (alkali metals). Using photoelectron-photoion coincidence imaging spectroscopy at variable photon energies (20-25 eV), we compare the rates of charge-transfer to Penning ionization of the dopants in the two cases. The surprising finding is that alkali metals, in contrast to the rare gases, are efficiently Penning ionized upon excitation of the (n=2)-bands of the host droplets. This indicates rapid migration of the excitation to the droplet surface, followed by relaxation, and eventually energy transfer to the alkali dopants

    Establishment of a model of murine odontoblasts underexpressing Pkd1 using shRNA

    Get PDF
    We have previously shown that PKD1, the gene encoding Polycystin-1 (or TRPP1) is expressed in human odontoblasts and that this protein is localized at the primary cilium of the cell. Nevertheless, its function remain unclear in this cell even if studies on osteoblasts, osteocytes and chondrocytes give TRPP1 as a promising candidate for mechanotransduction in response to mechanical stress. Consequently, to evaluate the role of TRPP1 in this transduction process, we needed first to generate an in vitro murine model down expressing Pkd1. Using lentivirus-mediated shRNA technology, we obtained a 60% suppression of Pkd1 mRNA expression in transfected MO6-G3 cells associated with a decrease of cell proliferation. Thus, establishment of this murine odontoblast model underexpressing Pkd1 associated with applied mechanical forces (compression or shear stress) will allow us to go further in the determination of TRPP1 involvement in odontoblasts mechanotransduction. Nous avons montré précédemment que PKD1, le gène codant pour la polycystine 1 ou TRPP1, est exprimé dans les cultures d’odontoblastes humains avec une localisation préférentielle de la protéine au niveau des cils primaires. Cependant, la fonction de TRPP1 reste à ce jour inconnue malgré un rôle potentiel de mécanotransducteur mis en évidence dans les ostéoblastes, ostéocytes et chondrocytes. Pour évaluer le rôle de cette protéine dans les odontoblastes nous avons choisi de mettre au point un modèle cellulaire sous-exprimant Pkd1. Ainsi, à l’aide de shRNA, nous avons obtenu une lignée cellulaire de souris (MO6-G3) sous-exprimant de façon stable Pkd1 (60% de sous-expression), et présentant une diminution de la prolifération cellulaire. Ce nouveau modèle cellulaire associé à l’application de forces mécaniques (compression ou étirement) devrait nous permettre d’évaluer l’implication de TRPP1 dans les processus de mécanotransduction des odontoblastes

    Energy Resolution Enhancement of Mercuric Iodide Detectors

    Get PDF
    A pulse processing technique has been developed which improves the gamma-ray energy resolution of mercuric iodide detectors. The technique employs a fast (100 ns) and a slow (6.4 µs) pulse height analysis to correct for signal variations due to variations in charge trapping. The capabilities of the technique for energy resolution enhancement are discussed as well as the utility of the technique for examining the trapping characteristics of individual detectors. We have achieved an energy resolution of 2.6% FWHM at 662 keV with an acceptance efficiency of 100% from a mercuric iodide detector which gives 8.3% FWHM using standard techniques

    On the Correlation of Torque and Luminosity in GX 1+4

    Get PDF
    Over five years of daily hard X-ray (>20 keV) monitoring of the 2-min accretion-powered pulsar GX 1+4 with the Compton Gamma Ray Observatory/BATSE large-area detectors has found nearly continuous rapid spin-down, interrupted by a bright 200-d spin-up episode. During spin-down, the torque becomes more negative as the luminosity increases (assuming that the 20-60 keV pulsed flux traces bolometric luminosity), the opposite of what is predicted by standard accretion torque theory. No changes in the shape of the 20-100 keV pulsed energy spectrum were detected, so that a very drastic change in the spectrum below 20 keV or the pulsed fraction would be required to make the 20-60 keV pulsed flux a poor luminosity tracer. These are the first observations which flatly contradict standard magnetic disk accretion theory, and they may have important implications for understanding the spin evolution of X-ray binaries, cataclysmic variables, and protostars. We briefly discuss the possibility that GX 1+4 may be accreting from a retrograde disk during spin-down, as previously suggested.Comment: 10 pages including 3 PS figures. To appear in ApJ Letter
    • …
    corecore