900 research outputs found

    Nova Geminorum 1912 and the Origin of the Idea of Gravitational Lensing

    Full text link
    Einstein's early calculations of gravitational lensing, contained in a scratch notebook and dated to the spring of 1912, are reexamined. A hitherto unknown letter by Einstein suggests that he entertained the idea of explaining the phenomenon of new stars by gravitational lensing in the fall of 1915 much more seriously than was previously assumed. A reexamination of the relevant calculations by Einstein shows that, indeed, at least some of them most likely date from early October 1915. But in support of earlier historical interpretation of Einstein's notes, it is argued that the appearance of Nova Geminorum 1912 (DN Gem) in March 1912 may, in fact, provide a relevant context and motivation for Einstein's lensing calculations on the occasion of his first meeting with Erwin Freundlich during a visit in Berlin in April 1912. We also comment on the significance of Einstein's consideration of gravitational lensing in the fall of 1915 for the reconstruction of Einstein's final steps in his path towards general relativity.Comment: 31 p

    F-18-FDG PET/CT in Infective Endocarditis:Indications and Approaches for Standardization

    Get PDF
    Purpose of Review: Additional imaging modalities, such as FDG-PET/CT, have been included into the workup for patients with suspected infective endocarditis, according to major international guidelines published in 2015. The purpose of this review is to give an overview of FDG-PET/CT indications and standardized approaches in the setting of suspected infective endocarditis. Recent Findings: There are two main indications for performing FDG-PET/CT in patients with suspected infective endocarditis: (i) detecting intracardiac infections and (ii) detection of (clinically silent) disseminated infectious disease. The diagnostic performance of FDG-PET/CT for intracardiac lesions depends on the presence of na

    Intravenous ibandronate reduces the incidence of skeletal complications in patients with breast cancer and bone metastases

    Get PDF
    Background: This phase III study compared the efficacy of the new potent bisphosphonate, ibandronate, with placebo as intravenous (i.v.) therapy in metastatic bone disease due to breast cancer. Patients and methods: A total of 466 patients were randomised to receive placebo (n = 158), or 2 mg (n = 154) or 6 mg (n = 154) ibandronate every 3-4 weeks for up to 2 years. The primary efficacy parameter was the number of 12-week periods with new bone complications, expressed as the skeletal morbidity period rate (SMPR). Bone pain, analgesic use and safety were evaluated monthly. Results SMPR was lower in both ibandronate groups compared with the placebo group; the difference was statistically significant for the ibandronate 6 mg group (P = 0.004 versus placebo). Consistent with the SMPR, ibandronate 6 mg significantly reduced the number of new bone events (by 38%) and increased time to first new bone event. Patients on ibandronate 6 mg also experienced decreased bone pain scores and analgesic use. Treatment with ibandronate was well tolerated. Conclusions: These results indicate that 6 mg i.v. ibandronate is effective and safe in the treatment of bone metastases from breast cance

    A mathematical description of nerve fiber bundle trajectories and their variability in the human retina

    Get PDF
    AbstractWe developed a mathematical model wherein retinal nerve fiber trajectories can be described and the corresponding inter-subject variability analyzed. The model was based on traced nerve fiber bundle trajectories extracted from 55 fundus photographs of 55 human subjects. The model resembled the typical retinal nerve fiber layer course within 20° eccentricity. Depending on the location of the visual field test point, the standard deviation of the calculated corresponding angular location at the optic nerve head circumference ranged from less than 1° to 18°, with an average of 8.8°

    Male-female differences in thoracic aortic diameters at presentation of acute type A aortic dissection

    Get PDF
    Background: Acute type A aortic dissection (ATAAD) is a highly lethal event, associated with aortic dilatation. It is not well known if patient height, weight or sex impact the thoracic aortic diameter (TAA) at ATAAD. The study aim was to identify male–female differences in TAA at ATAAD presentation. Methods: This retrospective cross-sectional study analysed all adult patients who presented with ATAAD between 2007 and 2017 in two tertiary care centres and underwent contrast enhanced computed tomography (CTA) before surgery. Absolute aortic diameters were measured at the sinus of Valsalva (SoV), ascending (AA) and descending thoracic aorta (DA) using double oblique reconstruction, and indexed for body surface area (ASI) and height (AHI). Z-scores were calculated using the Campens formula. Results: In total, 59 % (181/308) of ATAAD patients had CT-scans eligible for measurements, with 82 female and 99 male patients. Females were significantly older than males (65.5 ± 12.4 years versus 60.3 ± 2.3, p = 0.024). Female patients had larger absolute AA diameters than male patients (51.0 mm [47.0–57.0] versus 49.0 mm [45.0–53.0], p = 0.023), and larger ASI and AHI at all three levels. Z-scores for the SoV and AA were significantly higher for female patients (2.99 ± 1.66 versus 1.34 ± 1.77, p &lt; 0.001 and 5.27 [4.38–6.26] versus 4.06 [3.14–5.02], p &lt; 0.001). After adjustment for important clinical factors, female sex remained associated with greater maximal TAA (p = 0.019). Conclusion: Female ATAAD patients had larger absolute ascending aortic diameters than males, implying a distinct timing in disease presentation or selection bias. Translational studies on the aortic wall and studies on growth patterns should further elucidate these sex differences.</p

    Qualitative grading of aortic regurgitation: a pilot study comparing CMR 4D flow and echocardiography.

    Get PDF
    Over the past 10 years there has been intense research in the development of volumetric visualization of intracardiac flow by cardiac magnetic resonance (CMR).This volumetric time resolved technique called CMR 4D flow imaging has several advantages over standard CMR. It offers anatomical, functional and flow information in a single free-breathing, ten-minute acquisition. However, the data obtained is large and its processing requires dedicated software. We evaluated a cloud-based application package that combines volumetric data correction and visualization of CMR 4D flow data, and assessed its accuracy for the detection and grading of aortic valve regurgitation using transthoracic echocardiography as reference. Between June 2014 and January 2015, patients planned for clinical CMR were consecutively approached to undergo the supplementary CMR 4D flow acquisition. Fifty four patients(median age 39 years, 32 males) were included. Detection and grading of the aortic valve regurgitation using CMR4D flow imaging were evaluated against transthoracic echocardiography. The agreement between 4D flow CMR and transthoracic echocardiography for grading of aortic valve regurgitation was good (j = 0.73). To identify relevant,more than mild aortic valve regurgitation, CMR 4D flow imaging had a sensitivity of 100 % and specificity of 98 %. Aortic regurgitation can be well visualized, in a similar manner as transthoracic echocardiography, when using CMR 4D flow imaging

    F-18-FDG-Uptake in Mediastinal Lymph Nodes in Suspected Prosthetic Valve Endocarditis:Predictor or Confounder?

    Get PDF
    Introduction: Prosthetic valve endocarditis (PVE) is a serious disease affecting ~0.4% of prosthetic valve recipients per year. 18F-FDG-PET/CT has high sensitivity and specificity for PVE and is included as major criterion for the diagnosis in recent guidelines of the European Society of Cardiology. We addressed the question whether increased FDG-uptake in mediastinal lymph nodes could help to support the visual diagnostic assessment of PVE.Methods: In this sub-analysis of a previously published retrospective multicentre study, 160 unique patients were identified who underwent 18F-FDG-PET/CT for evaluation of suspected PVE. 18F-FDG-PET/CT was performed in adherence to the European Association of Nuclear Medicine guidelines of 2015 and scans were assessed for signs of mediastinal lymph node activity by 2 experienced nuclear medicine physicians who were blinded to clinical context. Clinical diagnosis of PVE had been established based on surgical findings or multidisciplinary consensus after a 1-year follow-up in 80 of 160 patients (50%).Results: In total, 52 patients showed increased mediastinal lymph node activity. Mediastinal lymph node activity on 18F-FDG-PET/CT did not increase diagnostic accuracy when added to the visual analysis of scans for signs of PVE: X2: 0.118, p = 0.731). After excluding patients with known confounders for 18F-FDG-PET/CT, namely use of Bioglue® during prosthetic valve implantation and C-reactive protein levels below 40 mg/L, mediastinal lymph node activity was still not of additional diagnostic value compared to visual analysis alone (X2:0.129, p = 0.723).Discussion: Assessment of mediastinal lymph node activity did not improve 18F-FDG-PET/CT diagnostic accuracy for suspected PVE compared to visual assessment of the valve alone, as it seems to be a rather a specific finding, that might be caused by sternal wound or mediastinal infections or even by subclinical respiratory infections. Future studies might elucidate whether increased FDG active lymph nodes indicate a high-risk patient group and whether more detailed assessment of mediastinal lymph nodes could improve their additional diagnostic benefit

    Added value of 18F-FDG-PET/CT and cardiac CTA in suspected transcatheter aortic valve endocarditis

    Get PDF
    Backgrounds: Transcatheter-implanted aortic valve infective endocarditis (TAVI-IE) is difficult to diagnose when relying on the Duke Criteria. Our aim was to assess the additional diagnostic value of 18F-fluorodeoxyglucose (18F-FDG) positron emission/computed tomography (PET/CT) and cardiac computed tomography angiography (CTA) in suspected TAVI-IE. Methods: A multicenter retrospective analysis was performed in all patients who underwent 18F-FDG-PET/CT and/or CTA with suspected TAVI-IE. Patients were first classified with Duke Criteria and after adding 18F-FDG-PET/CT and CTA, they were classified with European Society of Cardiology (ESC) criteria. The final diagnosis was determined by our Endocarditis Team based on ESC guideline recommendations. Results: Thirty patients with suspected TAVI-IE were included. 18F-FDG-PET/CT was performed in all patients and Cardiac CTA in 14/30. Using the Modified Duke Criteria, patients were classified as 3% rejected (1/30), 73% possible (22/30), and 23% definite (7/30) TAVI-IE. Adding 18F-FDG-PET/CT and CTA supported the reclassification of 10 of the 22 possible cases as “definite TAVI-IE” (5/22) or “rejected TAVI-IE” (5/22). This changed the final diagnosis to 20% rejected (6/30), 40% possible (12/30), and 40% definite (12/30) TAVI-IE. Conclusions: Addition of 18F-FDG-PET/CT and/or CTA changed the final diagnosis in 33% of patients and proved to be a valuable diagnostic tool in patients with suspected TAVI-IE

    Demonstration of Binding of Neuronal Calcium Sensor-1 to the Ca(v)2.1 P/Q-Type Calcium Channel

    Get PDF
    [Image: see text] In neurons, entry of extracellular calcium (Ca(2+)) into synaptic terminals through Ca(v)2.1 (P/Q-type) Ca(2+) channels is the driving force for exocytosis of neurotransmitter-containing synaptic vesicles. This class of Ca(2+) channel is, therefore, pivotal during normal neurotransmission in higher organisms. In response to channel opening and Ca(2+) influx, specific Ca(2+)-binding proteins associate with cytoplasmic regulatory domains of the P/Q channel to modulate subsequent channel opening. Channel modulation in this way influences synaptic plasticity with consequences for higher-level processes such as learning and memory acquisition. The ubiquitous Ca(2+)-sensing protein calmodulin (CaM) regulates the activity of all types of mammalian voltage-gated Ca(2+) channels, including the P/Q class, by direct binding to specific regulatory motifs. More recently, experimental evidence has highlighted a role for additional Ca(2+)-binding proteins, particularly of the CaBP and NCS families in the regulation of P/Q channels. NCS-1 is a protein found from yeast to humans and that regulates a diverse number of cellular functions. Physiological and genetic evidence indicates that NCS-1 regulates P/Q channel activity, including calcium-dependent facilitation, although a direct physical association between the proteins has yet to be demonstrated. In this study, we aimed to determine if there is a direct interaction between NCS-1 and the C-terminal cytoplasmic tail of the Ca(v)2.1 α-subunit. Using distinct but complementary approaches, including in vitro binding of bacterially expressed recombinant proteins, fluorescence spectrophotometry, isothermal titration calorimetry, nuclear magnetic resonance, and expression of fluorescently tagged proteins in mammalian cells, we show direct binding and demonstrate that CaM can compete for it. We speculate about how NCS-1/Ca(v)2.1 association might add to the complexity of calcium channel regulation mediated by other known calcium-sensing proteins and how this might help to fine-tune neurotransmission in the mammalian central nervous system
    corecore