3,560 research outputs found

    Development of a Detector Control System for the ATLAS Pixel Detector

    Get PDF
    The innermost part of the ATLAS experiment will be a pixel detector containing around 1750 individual detector modules. A detector control system (DCS) is required to handle thousands of I/O channels with varying characteristics. The main building blocks of the pixel DCS are the cooling system, the power supplies and the thermal interlock system, responsible for the ultimate safety of the pixel sensors. The ATLAS Embedded Local Monitor Board (ELMB), a multi purpose front end I/O system with a CAN interface, is foreseen for several monitoring and control tasks. The Supervisory, Control And Data Acquisition (SCADA) system will use PVSS, a commercial software product chosen for the CERN LHC experiments. We report on the status of the different building blocks of the ATLAS pixel DCS.Comment: 3 pages, 2 figures, ICALEPCS 200

    Spectral UV measurements in Austria from 1994 to 2006: investigations of short- and long-term changes

    Get PDF
    The influence of variability of atmospheric parameters on short- and long-term changes of spectral UV irradiance measured at the Sonnblick observatory (47.03° N, 12.57° E, 3106 m) during the period from 1994 to 2006 is studied. Measurements were performed with the Brewer #093 single-monochromator spectrophotometer and with a Bentham DM 150 spectroradiometer (double-monochromator). <br> <br> The influence of ozone, albedo, snowline and clouds on UV variability is evaluated for each parameter separately using 10-year climatology. It is found that the effect of total ozone on short-term variability of UV irradiance at 305 nm can be more than 200% and on average more than 50%. Clouds can cause variability of 150% or more and on average 35%. Variability caused by albedo reaches a maximum of 32% in April (6% on average). In summer and autumn, total ozone and clouds strongly influence the variability of UV radiation, whereas in winter and spring ozone has the more pronounced effect. A decrease in snowline height from 3000 m to 800 m a.s.l. enhances the UV irradiance by a factor of 1.24 for clear sky conditions and by a factor of 1.7 for 8/8 cloud cover. <br> <br> Long-term trends are investigated for the time period from 1994 to 2006 based on clear-sky measurements, using the non-parametric Mann-Kendall trend test. Significant downward trends (99% confidence level) are found for solar zenith angle 55° at wavelengths from 305 nm to 324 nm and erythemally weighted irradiance according to CIE, which are caused by an increase in sunshine duration during periods of high total column ozone. Significant trends (90% confidence level) were also found for other combinations of wavelength and SZA

    Between-Tactor Display Using Dynamic Tactile Stimuli

    Full text link
    Display of illusory vibration locations between physical vibrotactile motors (tactors) placed on the skin has the potential to reduce the number of tactors in distributed tactile displays. This paper presents a between-tactor display method that uses dynamic tactile stimuli to generate illusory vibration locations. A belt with only 6 vibration motors displays 24 targets consisting of on-tactor and between-tactor locations. On-tactor locations are represented by simply vibrating the relevant single tactor. Between-tactor locations are displayed by adjusting the relative vibration amplitudes of two adjacent motors, with either (1) constant vibration amplitudes or (2) perturbed vibration amplitudes (creating local illusory motion). User testing showed that perturbations improve recognition accuracy for in-between tactor localization

    A Combine On-Line Acoustic Flowmeter and Fluorocarbon Coolant Mixture Analyzer for The ATLAS Silicon Tracker

    Full text link
    An upgrade to the ATLAS silicon tracker cooling control system may require a change from C3F8 (octafluoro-propane) to a blend containing 10-30% of C2F6 (hexafluoro-ethane) to reduce the evaporation temperature and better protect the silicon from cumulative radiation damage with increasing LHC luminosity. Central to this upgrade is a new acoustic instrument for the real-time measurement of the C3F8/C2F6 mixture ratio and flow. The instrument and its Supervisory, Control and Data Acquisition (SCADA) software are described in this paper. The instrument has demonstrated a resolution of 3.10-3 for C3F8/C2F6 mixtures with ~20%C2F6, and flow resolution of 2% of full scale for mass flows up to 30gs-1. In mixtures of widely-differing molecular weight (mw), higher mixture precision is possible: a sensitivity of < 5.10-4 to leaks of C3F8 into the ATLAS pixel detector nitrogen envelope (mw difference 160) has been seen. The instrument has many potential applications, including the analysis of mixtures of hydrocarbons, vapours for semi-conductor manufacture and anaesthesia

    Development of a custom on-line ultrasonic vapour analyzer/flowmeter for the ATLAS inner detector, with application to gaseous tracking and Cherenkov detectors

    Full text link
    Precision sound velocity measurements can simultaneously determine binary gas composition and flow. We have developed an analyzer with custom electronics, currently in use in the ATLAS inner detector, with numerous potential applications. The instrument has demonstrated ~0.3% mixture precision for C3F8/C2F6 mixtures and < 10-4 resolution for N2/C3F8 mixtures. Moderate and high flow versions of the instrument have demonstrated flow resolutions of +/- 2% F.S. for flows up to 250 l.min-1, and +/- 1.9% F.S. for linear flow velocities up to 15 ms-1; the latter flow approaching that expected in the vapour return of the thermosiphon fluorocarbon coolant recirculator being built for the ATLAS silicon tracker.Comment: Paper submitted to TWEPP2012; Topical Workshop on Electronics for Particle Physics, Oxford, UK, September 17-21, 2012. KEYWORDS: Sonar; Saturated fluorocarbons; Flowmetry; Sound velocity, Gas mixture analysis. 8 pages, 7 figure

    Horticultural technique for rearing and redistribution of the sessile biological control agent, Rhizaspidiotus donacis on its host plant, Arundo donax

    Get PDF
    Arundo donax, giant reed is an invasive weed in the riparian habitats of the Rio Grande Basin. A biological control program using specialist insects from the native range in Mediterranean Europe, including the arundo scale, Rhi-zaspidiotus donacis has been implemented. The arundo scale is a sessile insect that spends most of its life cycle affixed to its host plant, thus creating challenges for its rearing and redistribution to field sites. A horticultural technique was developed which allowed for rearing of the scale on small, potted A. donax microplants, which could later be transplanted to field sites. Female scale reach maturity on the microplants and produce mobile crawler scale, which move to adjacent uninfested A. donax plants. Arundo scale were established at 48 sites on the Rio Grande using microplants. This horticultural technique allows for movement of the arundo scale at any stage of its life cycle to field sites to conduct biological control programs for A. donax where it is invasive

    Label-free electrochemical monitoring of DNA ligase activity

    Get PDF
    This study presents a simple, label-free electrochemical technique for the monitoring of DNA ligase activity. DNA ligases are enzymes that catalyze joining of breaks in the backbone of DNA and are of significant scientific interest due to their essential nature in DNA metabolism and their importance to a range of molecular biological methodologies. The electrochemical behavior of DNA at mercury and some amalgam electrodes is strongly influenced by its backbone structure, allowing a perfect discrimination between DNA molecules containing or lacking free ends. This variation in electrochemical behavior has been utilized previously for a sensitive detection of DNA damage involving the sugar-phosphate backbone breakage. Here we show that the same principle can be utilized for monitoring of a reverse process, i.e., the repair of strand breaks by action of the DNA ligases. We demonstrate applications of the electrochemical technique for a distinction between ligatable and unligatable breaks in plasmid DNA using T4 DNA ligase, as well as for studies of the DNA backbone-joining activity in recombinant fragments of E. coli DNA ligase
    • …
    corecore