1,592 research outputs found

    Non-tracking solar energy collector system

    Get PDF
    A solar energy collector system characterized by an improved concentrator for directing incident rays of solar energy on parallel vacuum-jacketed receivers or absorbers is described. Numerous individually mounted reflector modules of a common asymmetrical triangular cross-sectional configuration are supported for independent reorientation. Asymmetric vee-trough concentrators are defined

    Solar energy collection system

    Get PDF
    An improved solar energy collection system, having enhanced energy collection and conversion capabilities, is delineated. The system is characterized by a plurality of receivers suspended above a heliostat field comprising a multiplicity of reflector surfaces, each being adapted to direct a concentrated beam of solar energy to illuminate a target surface for a given receiver. A magnitude of efficiency, suitable for effectively competing with systems employed in collecting and converting energy extracted from fossil fuels, is indicated

    Solar energy receiver for a Stirling engine

    Get PDF
    A solar energy receiver includes a separable endless wall formed of a ceramic material in which a cavity of substantially cylindrical configuration is defined for entrapping solar flux. An acceptance aperture is adapted to admit to the cavity a concentrated beam of solar energy. The wall is characterized by at least one pair of contiguously related segments separated by lines of cleavage intercepting the aperture. At least one of the segments is supported for pivotal displacement. A thermal-responsive actuator is adapted to respond to excessive temperatures within the cavity for initiating pivoted displacement of one segment, whereby thermal flux is permitted to escape from the cavity

    A Nomographic Methodology for Use in Performance Trade-Off Studies of Parabolic Dish Solar Power Modules

    Get PDF
    A simple graphical method was developed to undertake technical design trade-off studies for individual parabolic dish models comprising a two-axis tracking parabolic dish with a cavity receiver and power conversion assembly at the focal point. The results of these technical studies are then used in performing the techno-economic analyses required for determining appropriate subsystem sizing. Selected graphs that characterize the performance of subsystems within the module were arranged in the form of a nomogram that would enable an investigator to carry out several design trade-off studies. Key performance parameters encompassed in the nomogram include receiver losses, intercept factor, engine rating, and engine efficiency. Design and operation parameters such as concentrator size, receiver type (open or windowed aperture), receiver aperture size, operating temperature of the receiver and engine, engine partial load characteristics, concentrator slope error, and the type of reflector surface, are also included in the graphical solution. Cost considerations are not included

    A fixed tilt solar collector employing reversible vee-trough reflectors and vacuum tube receivers for solar heating and cooling systems

    Get PDF
    The usefulness of vee-trough concentrators in improving the efficiency and reducing the cost of collectors assembled from evacuated tube receivers was studied in the vee-trough/vacuum tube collector (VTVTC) project. The VTVTC was analyzed rigorously and various mathematical models were developed to calculate the optical performance of the vee-trough concentrator and the thermal performance of the evacuated tube receiver. A test bed was constructed to verify the mathematical analyses and compare reflectors made out of glass, Alzak and aluminized FEP Teflon. Tests were run at temperatures ranging from 95 to 180 C. Vee-trough collector efficiencies of 35 to 40% were observed at an operating temperature of about 175 C. Test results compared well with the calculated values. Predicted daily useful heat collection and efficiency values are presented for a year's duration of operation temperatures ranging from 65 to 230 C. Estimated collector costs and resulting thermal energy costs are presented. Analytical and experimental results are discussed along with a complete economic evaluation

    A fixed tilt solar collector employing reversible vee-through reflectors and evaluated tube receivers for solar heating and cooling systems

    Get PDF
    The Vee-Trough/Evacuated Tube Collector (VTETC) was analyzed rigorously and various mathematical models were developed to calculate the optical performance of the vee-trough concentrators, and the quasi-steady state thermal performance of the evacuated tube receivers. Tests were run to verify the mathematical analyses. Back-silvered glass mirror, Alzak, Aluminized Teflon, and Kinglux (electropolished aluminum reflectors) were tested. Additional tests were run at temperatures ranging from 80 to 190 C (176-374 F). For the glass mirror reflectors, peak efficiencies, based on aperture area and operating temperatures of 125 C (257 F), were over 40%. Efficiencies of about 40% were observed at temperatures of 150 C (302 F) and 30% at 175 C (347 F). Test data for several days, predicted daily useful heats, and efficiency values are presented for a full year. These theoretical values were then compared with actual data points for the same temperature range

    Parabolic dish test site: History and operating experience

    Get PDF
    The parabolic dish test site (PDTS) was established for testing point-focusing solar concentrator systems operating at temperatures approaching 1650 C. Among tests run were evaluation and performance characterization of parabolic dish concentrators, receivers, power conversion units, and solar/fossil-fuel hybrid systems. The PDTS was fully operational until its closure in June, 1984. The evolution of the test program, a chronological listing of the experiments run, and data summaries for most of the tests conducted are presented

    Investıgatıon of Removal of Dye from Aqueous Solutıon by Advanced Treatment

    Get PDF
    The textile dyeing and finishing industry use a significant amount of water and produce water pollution. Conventional biological treatment processes have some difficulties for degradation of nonbiodegradable compounds. Dye-bearing wastewaters have high COD and colour. In this study, a photo reactor process was used to remove color from aqueous solution.Effects of pH on Reactive Red 4 and cationic dye removal using 1g/L TiO2, as catalyst were studied at constant inital dye concentration (25 mg/l). Cationic dye removal efficiency is better than Reactive dye removal efficiency for photocatalytic oxidation in this stud

    Effects of stress produced by adrenocorticotropin (ACTH) on lipid peroxidation and some antioxidants in vitamin C treated and nontreated chickens

    Get PDF
    The aim of this study was to examine the effects of vitamin C on malonaldehyde (MDA) and glutathione (GSH) concentrations, and superoxide dismutase (SOD) and glutathione peroxidase (GSH-Px) activity in chickens stressed by adrenocorticotropin (ACTH). Sixty Leghorn chickens (20 weeks old) were randomly allotted to a control and a vitamin C treated group. An isotonic sodium chloride solution was administrated intramuscularly for a period of five days to the control group at a dose of 2.5 mL per chicken per day, and the treatment group received a vitamin C solution (containing 250 mg vitamin C/2.5 mL) intramuscularly for five days. On the fifth day of the experiment the chickens in both groups received 50 IU ACTH intramuscularly. Three hours after ACTH application blood samples were collected to determine the concentrations of MDA and GSH, and activities of SOD and GSH-Px in the blood. The concentration of MDA in the control group increased compared to that in the vitamin C treated group. After the ACTH application the activity of SOD increased in both groups, thought significantly so in the vitamin C treated group. The GSH-Px activity did not differ significantly between the treatments after ACTH application. It was concluded that intramuscularly administrated vitamin C facilitated an adaptation against stress and decreased negative effects of stress in chickens. Keywords: ACTH, glutathione (GSH), Glutathione peroxidase (GSH-Px), Malonaldehyde (MDA), Superoxide dismutase (SOD), Vitamin C South African Journal of Animal Science Vol.33(3) 2003: 201-20
    corecore