255 research outputs found

    Diagnosis and localization of fault for a neutral point clamped inverter in wind energy conversion system using artificial neural network technique

    Get PDF
    Introduction. To attain high efficiency and reliability in the field of clean energy conversion, power electronics play a significant role in a wide range of applications. More effort is being made to increase the dependability of power electronics systems. Purpose. In order to avoid any undesirable effects or disturbances that negatively affect the continuity of service in the field of energy production, this research provides a fault detection technique for insulated-gate bipolar transistor open-circuit faults in a three-level diode-clamped inverter of a wind energy conversion system predicated on a doubly-fed induction generator. The novelty of the suggested work ensures the regulation of power exchanged between the system and the grid without faults, advanced intelligence approaches based on a multilayer artificial neural network are used to discover and locate this type of defect; the database is based on the module and phase angle of three-phase stator currents of induction generators. The proposed methods are designed for the detection of one or two open-circuit faults in the power switches of the side converter of a doubly-fed induction generator in a wind energy conversion system. Methods. In the proposed detection method, only the three-phase stator current module and phase angle are used to identify the faulty switch. The primary goal of this fault diagnosis system is to effectively detect and locate failures in one or even more neutral point clamped inverter switches. Practical value. The performance of the controllers is evaluated under different operating conditions of the power system, and the reliability, feasibility, and effectiveness of the proposed fault detection have been verified under various open-switch fault conditions. The diagnostic approach is also robust to transient conditions posed by changes in load and speed. The proposed diagnostic technique's performance and effectiveness are both proven by simulation in the SimPower /Simulink® MATLAB environment.Вступ. Для досягнення високої ефективності та надійності у галузі чистого перетворення енергії силова електроніка відіграє важливу роль у широкому спектрі застосування. Докладаються зусилля для підвищення надійності систем силової електроніки. Мета. Щоб уникнути будь-яких небажаних ефектів або перешкод, що негативно впливають на безперервність роботи в галузі виробництва енергії, у цьому дослідженні пропонується методика виявлення несправностей біполярних транзисторів із ізольованим затвором при обриві ланцюга в трирівневому інверторі з діодною фіксацією системи перетворення енергії вітру, що ґрунтується на асинхронному генераторі з подвійним живленням. Новизна запропонованої роботи забезпечує регулювання потужності, що обмінюється між системою та мережею, без збоїв, для виявлення та локалізації цього типу дефекту використовуються передові інтелектуальні підходи, засновані на багатошаровій штучній нейронній мережі; база даних заснована на модулі та фазовому куті трифазних статорних струмів асинхронних генераторів. Запропоновані методи призначені для виявлення одного або двох обривів у силових ключах бокового перетворювача асинхронного генератора подвійного живлення у системі перетворення енергії вітру. Методи. У запропонованому методі виявлення для ідентифікації несправного вимикача використовуються тільки трифазний модуль струму статора і фазовий кут. Основною метою цієї системи діагностики несправностей є ефективне виявлення та локалізація відмов в одному або навіть кількох інверторних перемикачах з фіксованою нейтральною точкою. Практична цінність. Робочі характеристики контролерів оцінюються за різних умов роботи енергосистеми, а надійність, здійсненність та ефективність запропонованого виявлення несправностей були перевірені за різних умов відмови розімкнутого вимикача. Діагностичний підхід також стійкий до перехідних станів, спричинених змінами навантаження та швидкості. Продуктивність та ефективність запропонованого діагностичного методу підтверджені моделюванням у середовищі SimPower/Simulink® MATLAB

    Fault diagnosis of power converters in a grid connected photovoltaic system using artificial neural networks

    Get PDF
    Introduction. The widespread use of photovoltaic systems in various applications has spotlighted the pressing requirement for reliability, efficiency and continuity of service. The main impediment to a more effective implementation has been the reliability of the power converters. Indeed, the presence of faults in power converters that can cause malfunctions in the photovoltaic system, which can reduce its performance. Novelty. This paper presents a technique for diagnosing open circuit failures in the switches (IGBTs) of power converters (DC-DC converters and three-phase inverters) in a grid-connected photovoltaic system. Purpose. To ensure supply continuity, a fault-diagnosis process is required throughout all phases of energy production, transfer, and conversion. Methods. The diagnostic approach is based on artificial neural networks and the extraction of features corresponding to the open circuit fault of the IGBT switch. This approach is based on the Clarke transformation of the three-phase currents of the inverter output as well as the calculation of the average value of these currents to determine the exact angle of the open circuit fault. Results. This method is able to effectively identify and localize single or multiple open circuit faults of the DC-DC converter IGBT switch or the three-phase inverter IGBT switches.Вступ. Широке використання фотоелектричних систем у різних застосуваннях висунуло на перший план нагальні вимоги до надійності, ефективності та безперервності обслуговування. Основною перешкодою для ефективнішого застосування була надійність силових перетворювачів. Справді, наявність несправностей у силових перетворювачах може спричинити збої в роботі фотоелектричної системи, що може знизити її продуктивність. Новизна. У цій статті представлена методика діагностики обриву кола в перемикачах (IGBT) силових перетворювачів (перетворювачів постійного струму та трифазних інверторів) у фотоелектричній системі, підключеній до мережі. Мета. Для забезпечення безперервності постачання потрібен процес діагностики несправностей на всіх етапах виробництва, передачі та перетворення енергії. Методи. Діагностичний підхід заснований на штучних нейронних мережах та вилучення ознак, що відповідають обриву кола IGBT-перемикача. Цей підхід ґрунтується на перетворенні Кларка трифазних струмів на виході інвертора, а т акож розрахунку середнього значення цих струмів для визначення точного кута обриву кола. Результати. Цей метод дозволяє ефективно ідентифікувати та локалізувати одиночні або множинні несправності розімкнутого кола IGBT-перемикача DC-DC перетворювача або IGBT-перемикача трифазного інвертора

    Multi-scale analysis of the effect of loading conditions on monotonic and fatigue behavior of a glass fiber reinforced polyphenylene sulfide (PPS) composite

    Get PDF
    In this paper, two kinds of PPS/GF composite samples (PPS-0°, PPS-90°) were prepared with two different fiber main orientations related to the injection direction. A wide range of their properties were discussed. Using DMTA analysis, it was shown that the PPS/GF composite under study obeyed the time-temperature equivalence principle. Moreover, Perez model was verified and gave a good estimation of the viscoelastic properties of the PPS/GF. Monotonic and fatigue behaviors and fatigue life of PPS/GF were investigated. Fiber's orientation, applied amplitude and loading frequency effects were emphasized. Self-heating effect on fatigue strength was also analyzed. SEM fracture surface observations allowed analyzing, at the local scale, the main deformation mechanisms occurring during mechanical loading. No evident damage development was observed for both monotonic and fatigue loading. PPS matrix plasticity appeared to be the predominant deformation mechanism until a semi-ductile or semi-brittle final failure depending on the loading conditions and local microstructure

    A Novel Target-Height Estimation Approach Using Radar-Wave Multipath Propagation for Automotive Applications

    Get PDF
    This paper introduces a novel target height estimation approach using a Frequency Modulation Continuous Wave (FMCW) automotive radar. The presented algorithm takes advantage of radar wave multipath propagation to measure the height of objects in the vehicle surroundings. A multipath propagation model is presented first, then a target height is formulated using geometry, based on the presented propagation model. It is then shown from Sensor-Target geometry that height estimation of targets is highly dependent on the radar range resolution, target range and target height. The high resolution algorithm RELAX is discussed and applied to collected raw data to enhance the radar range resolution capability. This enables a more accurate height estimation especially for low targets. Finally, the results of a measurement campaign using corner reflectors at different heights are discussed to show that target heights can be very accurately resolved by the proposed algorithm and that for low targets an average mean height estimation error of 0.03 m has been achieved by the proposed height finding algorithm

    Fault diagnosis of power converters in a grid connected photovoltaic system using artificial neural networks

    Get PDF
    Introduction. The widespread use of photovoltaic systems in various applications has spotlighted the pressing requirement for reliability, efficiency and continuity of service. The main impediment to a more effective implementation has been the reliability of the power converters. Indeed, the presence of faults in power converters that can cause malfunctions in the photovoltaic system, which can reduce its performance. Novelty. This paper presents a technique for diagnosing open circuit failures in the switches (IGBTs) of power converters (DC-DC converters and three-phase inverters) in a grid-connected photovoltaic system. Purpose. To ensure supply continuity, a fault-diagnosis process is required throughout all phases of energy production, transfer, and conversion. Methods. The diagnostic approach is based on artificial neural networks and the extraction of features corresponding to the open circuit fault of the IGBT switch. This approach is based on the Clarke transformation of the three-phase currents of the inverter output as well as the calculation of the average value of these currents to determine the exact angle of the open circuit fault. Results. This method is able to effectively identify and localize single or multiple open circuit faults of the DC-DC converter IGBT switch or the three-phase inverter IGBT switches

    Low Doses of Bisphenol A and Diethylstilbestrol Impair Ca(2+) Signals in Pancreatic α-Cells through a Nonclassical Membrane Estrogen Receptor within Intact Islets of Langerhans

    Get PDF
    Glucagon, secreted from pancreatic α-cells integrated within the islets of Langerhans, is involved in the regulation of glucose metabolism by enhancing the synthesis and mobilization of glucose in the liver. In addition, it has other extrahepatic effects ranging from lipolysis in adipose tissue to the control of satiety in the central nervous system. In this article, we show that the endocrine disruptors bisphenol A (BPA) and diethylstilbestrol (DES), at a concentration of 10(−9) M, suppressed low-glucose–induced intracellular calcium ion ([Ca(2+)](i)) oscillations in α-cells, the signal that triggers glucagon secretion. This action has a rapid onset, and it is reproduced by the impermeable molecule estradiol (E(2)) conjugated to horseradish peroxidase (E-HRP). Competition studies using E-HRP binding in immunocytochemically identified α-cells indicate that 17β-E(2), BPA, and DES share a common membrane-binding site whose pharmacologic profile differs from the classical ER. The effects triggered by BPA, DES, and E(2) are blocked by the Gαi- and Gα(o)-protein inhibitor pertussis toxin, by the guanylate cyclase–specific inhibitor 1H-[1,2,4] oxadiazolo[4,3-a] quinoxalin-1-one, and by the nitric oxide synthase inhibitor N-nitro-l-arginine methyl ester. The effects are reproduced by 8-bromo-guanosine 3′,5′-cyclic monophosphate and suppressed in the presence of the cGMP-dependent protein kinase inhibitor KT-5823. The action of E(2), BPA, and DES in pancreatic α-cells may explain some of the effects elicited by endocrine disruptors in the metabolism of glucose and lipid

    Coupled effect of loading frequency and amplitude on the fatigue behavior of advanced sheet molding compound (A-SMC)

    Get PDF
    This paper presents the experimental results of tension-tension stress-controlled fatigue tests performed on advanced sheet molding compound (A-SMC). It aims at analyzing the effect of fiber orientation, loading amplitude, and frequency on the fatigue response and the related temperature evolution due to the self-heating phenomenon. Two types of A-SMC have been analyzed: randomly oriented (RO) and highly oriented (HO). The coupled effect of the loading amplitude and the frequency has been studied. It has been shown that the couple frequency-amplitude affects the nature of the fatigue overall response which can be governed by the damage mechanisms accumulation (mechanical fatigue) and/or by the self-heating (induced thermal fatigue). For fatigue loading at 100 Hz, self-heating has been observed and yielded to a temperature rise up to 70 C. The latter causes a decrease of the storage modulus related to the b-transition of the vinylester. It has been demonstrated that the self-heating produced a material softening and decreased the fatigue life. SEM observations revealed that the samples tested at 100 Hz, exhibit smooth debonding surfaces due to the induced thermal softening of the matrix whereas more brittle fracture of the matrix surrounding fibers is observed during the fatigue tests achieved at 10 Hz

    Sheet Molding Compound Automotive Component Reliability Using a Micromechanical Damage Approach

    Get PDF
    The mastering of product reliability is essential for industrial competitiveness. If for metallic materials the topic is well-known, especially in automotive industry, Original Equipment Manufacturers are expecting strong support of their suppliers to full-fill the lack data. This paper presents a new original approach, using a micromechanical based on damage model to address the problem of reliability of Sheet Molding Compound (SMC) components. The first part demonstrates the inadequacy of the standard method of reliability on SMC material through its application on the new Peugeot 3008. In fact, the very flat S-N curve of SMC, and in general, composite materials is not appropriate for acceleration effect. The proposed model correlates the stress, damage and strength with both cycle number and slamming velocity. It emphasizes the relation between the effective distribution with the slamming velocity effect. Then, a new reliability approach based on a micromechanical fatigue/damage model was developed. The definition of new probability distributions based on damage was necessary to apply properly the stress-resistance approach. It allows taking into account the velocity effect by switching in damage space. Finally, applying this new methodology on the Peugeot 3008, leads to the definition of the optimal validation laboratory tests to ensure the reliability. Indeed, the required number of cycles to ensure reliability has been reduced significantly. Micromechanical damage reliability approach could be an efficient way to ensure the reliability of short fiber reinforcement composite components used in industrial context.Authors address a strong acknowledgment to E. FEIGE and Y. HAMOY, from PSA, for the data provided. Their comments and advices were also very useful.We are grateful to Mr. OZOUF for teaching and advices on the general topic of reliability

    The emergency department arrival mode and its relations to ED management and 30-day mortality in acute heart failure: an ancillary analysis from the EURODEM study

    Full text link
    Background Acute heart failure patients are often encountered in emergency departments (ED) from 11% to 57% using emergency medical services (EMS). Our aim was to evaluate the association of EMS use with acute heart failure patients' ED management and short-term outcomes. Methods This was a sub-analysis of a European EURODEM study. Data on patients presenting with dyspnoea were collected prospectively from European EDs. Patients with ED diagnosis of acute heart failure were categorized into two groups: those using EMS and those self-presenting (non- EMS). The independent association between EMS use and 30-day mortality was evaluated with logistic regression. Results Of the 500 acute heart failure patients, with information about the arrival mode to the ED, 309 (61.8%) arrived by EMS. These patients were older (median age 80 vs. 75 years, p 30/min in 17.1% patients vs. 7.5%, p = 0.005). The only difference in ED management appeared in the use of ventilatory support: 78.3% of EMS patients vs. 67.5% of non- EMS patients received supplementary oxygen (p = 0.007), and non-invasive ventilation was administered to 12.5% of EMS patients vs. 4.2% non- EMS patients (p = 0.002). EMS patients were more often hospitalized (82.4% vs. 65.9%, p < 0.001), had higher in-hospital mortality (8.7% vs. 3.1%, p = 0.014) and 30-day mortality (14.3% vs. 4.9%, p < 0.001). The use of EMS was an independent predictor of 30-day mortality (OR = 2.54, 95% CI 1.11-5.81, p = 0.027). Conclusion Most acute heart failure patients arrive at ED by EMS. These patients suffer from more severe respiratory distress and receive more often ventilatory support. EMS use is an independent predictor of 30-day mortality

    Pre-hospital management protocols and perceived difficulty in diagnosing acute heart failure

    Get PDF
    Aim To illustrate the pre-hospital management arsenals and protocols in different EMS units, and to estimate the perceived difficulty of diagnosing suspected acute heart failure (AHF) compared with other common pre-hospital conditions. Methods and results A multinational survey included 104 emergency medical service (EMS) regions from 18 countries. Diagnostic and therapeutic arsenals related to AHF management were reported for each type of EMS unit. The prevalence and contents of management protocols for common medical conditions treated pre-hospitally was collected. The perceived difficulty of diagnosing AHF and other medical conditions by emergency medical dispatchers and EMS personnel was interrogated. Ultrasound devices and point-of-care testing were available in advanced life support and helicopter EMS units in fewer than 25% of EMS regions. AHF protocols were present in 80.8% of regions. Protocols for ST-elevation myocardial infarction, chest pain, and dyspnoea were present in 95.2, 80.8, and 76.0% of EMS regions, respectively. Protocolized diagnostic actions for AHF management included 12-lead electrocardiogram (92.1% of regions), ultrasound examination (16.0%), and point-of-care testings for troponin and BNP (6.0 and 3.5%). Therapeutic actions included supplementary oxygen (93.2%), non-invasive ventilation (80.7%), intravenous furosemide, opiates, nitroglycerine (69.0, 68.6, and 57.0%), and intubation 71.5%. Diagnosing suspected AHF was considered easy to moderate by EMS personnel and moderate to difficult by emergency medical dispatchers (without significant differences between de novo and decompensated heart failure). In both settings, diagnosis of suspected AHF was considered easier than pulmonary embolism and more difficult than ST-elevation myocardial infarction, asthma, and stroke. Conclusions The prevalence of AHF protocols is rather high but the contents seem to vary. Difficulty of diagnosing suspected AHF seems to be moderate compared with other pre-hospital conditions
    corecore