296 research outputs found
Support vector machines categorize the scaling of human grip configurations
In previous work (Cesari & Newell, 2002), we used a graphical dimensional analysis to show that grip transitions obey the body-scaled relation K = InLo + InMo/(a + bM(h) + cL(h)), where L-o and M-o are the object's length and mass, and L-h and M-h the length and mass of the grasper's hand. However, the generality of the equation was limited by the ad hoc graphical method that defined the lines for grip separation and by the assumption that these lines be negatively sloped and parallel to one another. This article reports an independent test of this relation by the geometrical and statistical categorization of body-scaled invariants for the transition of human grip configurations through support vector machines (SVMs). The SVM analysis confirmed the fit of linear, negatively sloped, and approximately parallel transition boundaries in the scaling of human grip configuration within a single hand. The SVM analysis has provided a theoretical refinement to the scaling model of human grip configurations
The effect of proprioceptive knee bracing on knee stability during three different sport related movement tasks in healthy subjects and the implications to the management of Anterior Cruciate Ligament (ACL) injuries
Abstract
Introduction: Proprioceptive knee braces have been shown to improve knee mechanics, however much of the work to date has focused on tasks such as slow step down tasks rather than more dynamic sporting tasks.
Objective: This study aimed to explore if such improvements in stability may be seen during faster sports specific tasks as well as slower tasks.
Method: Twelve subjects performed a slow step down, single leg drop jump and pivot turn jump with and without a silicone web brace. 3D kinematics of the knee were collected using a ten camera Qualisys motion analysis system. Reflective markers were placed on the foot, shank, thigh and pelvis using the Calibrated Anatomical Systems Technique. A two way ANOVA with repeated measures was performed with post-hoc pairwise comparison to explore the differences between the two conditions and three tasks.
Results: Significant differences were seen in the knee joint angles and angular velocities in the sagittal, coronal and transverse planes between the tasks. The brace showed a reduction in knee valgum and internal rotation across all tasks, with the most notable effect during the single leg drop jump and pivot turn jump. The transverse plane also showed a significant reduction in the external rotation knee angular velocity when wearing the brace.
Discussion: The brace influenced the knee joint kinematics in coronal and transverse planes which confirms that such braces can have a significant effect on knee control during dynamic tasks. Further studies are required exploring the efficacy of proprioceptive braces in athletic patient cohort.
Acknowledgements
This study is partly founded by Erasmus+ program who have sponsored two masters students. The braces were supplied by DJO Global, Inc. The suppliers played no role in the design, execution, analysis and interpretation of the data or writing of this study
Ultrasound imaging of the carpal tunnel during median nerve compression
Median nerve (MN) compression is a recognized component of carpal tunnel syndrome (CTS). In order to document compressive changes in the MN during hand activity, the carpal tunnel was imaged with neuromuscular ultrasound (NMUS). Ten patients with CTS and five normal controls underwent NMUS of the MN at rest and during dynamic stress testing (DST). DST maneuvers involve sustained isometric flexion of the distal phalanges of the first three digits. During DST in the CTS patients, NMUS demonstrated MN compression between the contracting thenar muscles ventrally and the taut flexor tendons dorsally. The mean MN diameter decreased nearly 40%, with focal narrowing in the mid-distal carpal canal. Normal controls demonstrated no MN compression and a tendency towards MN enlargement, with an average diameter increase of 17%. Observing the pathologic mechanism of MN injury during common prehensile hand movements could help better understand how to treat and prevent CTS
Measurements of knee rotation-reliability of an external device in vivo
<p>Abstract</p> <p>Background</p> <p>Knee rotation plays an important part in knee kinematics during weight-bearing activities. An external device for measuring knee rotation (the Rottometer) has previously been evaluated for validity by simultaneous measurements of skeletal movements with Roentgen Stereometric Analysis (RSA). The aim of this study was to investigate the reliability of the device.</p> <p>Method</p> <p>The within-day and test-retest reliability as well as intertester reliability of the device in vivo was calculated. Torques of 3, 6 and 9 Nm and the examiner's apprehension of end-feel were used at 90°, 60° and 30° of knee flexion. Intraclass Correlation Coefficient <sub>2,1 </sub>(ICC <sub>2,1</sub>), 95% confidence interval (CI) of ICC and 95% CI between test trials and examiners were used as statistical tests.</p> <p>Result</p> <p>ICC<sub>2,1 </sub>ranged from 0.50 to 0.94 at all three flexion angles at 6 and 9 Nm as well as end-feel, and from 0.22 to 0.75 at 3 Nm applied torque.</p> <p>Conclusion</p> <p>The Rottometer was a reliable measurement instrument concerning knee rotation at the three different flexion angles (90°, 60° and 30°) with 6 and 9 Nm applied torques as well as the examiner's apprehension of end-feel. Three Nm was not a reliable torque. The most reliable measurements were made at 9 Nm applied torque.</p
Damages of the tibial post in constrained total knee prostheses in the early postoperative course – a scanning electron microscopic study of polyethylene inlays
<p>Abstract</p> <p>Background</p> <p>Investigation of the risk of fracture of the polyethylene (PE) inlay in constrained total knee prostheses.</p> <p>Methods</p> <p>Three unused and seven polyethylene inlays that had been implanted in a patient's knee for an average of 25.4 months (min 1.1 months, max 50.2 months) were investigated using scanning electron microscopy (SEM). All inlays were of the same type and size (Genesis II constrained, Smith & Nephew). The PE surface at the transition from the plateau to the post was analyzed.</p> <p>Results</p> <p>The unused inlays had fissure-free surfaces. All inlays that had been implanted in a patient's knee already had distinct fissures at the front and backside of the post.</p> <p>Conclusion</p> <p>The fissures of the transition from the plateau to the post indicated a loading-induced irreversible mechanical deformation and possibly cause the fracture of the inlay.</p
External rotation during elevation of the arm
Background Knowledge about the pattern of rotation during arm elevation is necessary for a full understanding of shoulder function, and it is also useful for planning of rehabilitation protocols to restore range of motion in shoulders in disorder. However, there are insufficient in vivo data available
The Clinical Assessment Study of the Hand (CAS-HA): a prospective study of musculoskeletal hand problems in the general population
<p>Abstract</p> <p>Background</p> <p>Pain in the hand affects an estimated 12–21% of the population, and at older ages the hand is one of the most common sites of pain and osteoarthritis. The association between symptomatic hand osteoarthritis and disability in everyday life has not been studied in detail, although there is evidence that older people with hand problems suffer significant pain and disability. Despite the high prevalence of hand problems and the limitations they cause in older adults, little attention has been paid to the hand by health planners and policy makers. We plan to conduct a prospective, population-based, observational cohort study designed in parallel with our previously reported cohort study of knee pain, to describe the course of musculoskeletal hand problems in older adults and investigate the relative merits of different approaches to classification and defining prognosis.</p> <p>Methods/Design</p> <p>All adults aged 50 years and over registered with two general practices in North Staffordshire will be invited to take part in a two-stage postal survey. Respondents to the survey who indicate that they have experienced hand pain or problems within the previous 12 months will be invited to attend a research clinic for a detailed assessment. This will consist of clinical interview, hand assessment, screening test of lower limb function, digital photography, plain x-rays, anthropometric measurement and brief self-complete questionnaire. All consenting clinic attenders will be followed up by (i) general practice medical record review, (ii) repeat postal questionnaire at 18-months, and (iii) repeat postal questionnaire at 3 years.</p> <p>Discussion</p> <p>This paper describes the protocol for the Clinical Assessment Study of the Hand (CAS-HA), a prospective, population-based, observational cohort study of community-dwelling older adults with hand pain and hand problems based in North Staffordshire.</p
- …