273 research outputs found

    Rigidité artérielle mesurée par pOpmètre® chez les patients à risque cardiovasculaire, lien aux plaques d’athérome carotidien

    Get PDF
    PURPOSE: Aortic stiffness is a functional and structural consequence of ageing and arteriosclerosis. Regional arterial stiffness can be easily evaluated using pOpmetre(®) (Axelife SAS, France). This new technique assesses the pulse wave transit time (TT) between the finger (TTf) and the toe (TTt). Based on height chart, regional pulse wave velocity (PWV) between the toe and the finger can be estimated (PWVtf). pOpscore(®) index is also calculated as the ratio between PWVtoe and PWVfinger and can be considered as a peripheral vascular stiffness index. The aim of the study was to evaluate the relationship between pOpmetre(®) indices and the presence of carotid plaques in a population with cardiovascular risk factors. METHODS: In 77 consecutive patients recruited for a vascular screening for atherosclerosis (46 men aged 54 ± 2 years; 31 women aged 49 ± 3 years; ns), the difference between TTt and TTf (called Dt-f), the regional pulse wave velocity between the toe and the finger (PWVtf = constant × height/Dt-fm/s) and pOpscore(®) were measured by pOpmetre(®). Presence of carotid plaques was assessed using ultrasound imaging. The local aortic stiffness (AoStiff) was evaluated by the Physioflow(®) system. RESULTS: No difference was found between patients with or without carotid plaques (n=25 versus 52) for Ankle-Brachial Pressure Index (ABPI: 1.15 ± 0.04 versus 1.12 ± 0.03), nor for diastolic or systolic blood pressure (87 ± 3 versus 82 ± 2; 137 ± 3 versus 132 ± 2 mmHg). The first group was older than the second (59 ± 2 versus 49 ± 2 years, P<0.002) with a larger intimae media thickness (0.69 ± 0.02 versus 0.63 ± 0.01 mm, P<0.004), a higher AoStiff (10.4 ± 0.7 versus 8.2 ± 0.5m/s, P<0.02), and PWVtf (14.3 ± 1.0 versus 10.7 ± 0.7 m/s, P<0.004) and a shorter Dt-f (57.9 ± 5.1 versus 73.5 ± 3.5 ms, P<0.01). PWVtf (r(2)=0.49, P<0.0001) and Dt-f (r(2)=0.54, P<0.0001) correlated with age. A significant difference in pOpscore(®) index was observed between both groups (1.51 ± 0.3 versus 1.41 ± 0.2, P<0.006). CONCLUSION: Our results show a significant arterial stiffness indices measured by pOpmetre(®) in patients with and without carotid plaques

    "To D or not to D? That is the question" Talking about dialysis: Use of Best Case/Worst Case communication tool.

    Get PDF
    Presented as a Poster Presentation at 2020 IUSM Education Day

    Th1 type lymphocyte reactivity to metals in patients with total hip arthroplasty

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>All prostheses with metallic components release metal debris that can potentially activate the immune system. However, implant-related metal hyper-reactivity has not been well characterized. In this study, we hypothesized that adaptive immunity reaction(s), particularly T-helper type 1 (Th1) responses, will be dominant in any metal-reactivity responses of patients with total joint replacements (TJAs). We tested this hypothesis by evaluating lymphocyte reactivity to metal "ions" in subjects with and without total hip replacements, using proliferation assays and cytokine analysis.</p> <p>Methods</p> <p>Lymphocytes from young healthy individuals without an implant or a history of metal allergy (Group 1: n = 8) were used to assess lymphocyte responses to metal challenge agents. In addition, individuals (Group 2: n = 15) with well functioning total hip arthroplasties (average Harris Hip Score = 91, average time in-situ 158 months) were studied. Age matched controls with no implants were also used for comparison (Group 3, n = 8, 4 male, 4 female average age 70, range 49–80). Group 1 subjects' lymphocyte proliferation response to Aluminum<sup>+3</sup>, Cobalt<sup>+2</sup>, Chromium<sup>+3</sup>, Copper<sup>+2</sup>, Iron<sup>+3</sup>, Molybdenum<sup>+5</sup>, Manganeese<sup>+2</sup>, Nickel<sup>+2</sup>, Vanadium<sup>+3 </sup>and Sodium<sup>+2 </sup>chloride solutions at a variety of concentrations (0.0, 0.05, 0.1, 0.5, 1.0 and 10.0 mM) was studied to establish toxicity thresholds. Mononuclear cells from Group 2 and 3 subjects were challenged with 0.1 mM CrCl<sub>3</sub>, 0.1 mM NiCl<sub>2</sub>, 0.1 mM CoCl<sub>2 </sub>and approx. 0.001 mM titanium and the reactions measured with proliferation assays and cytokine analysis to determine T-cell subtype prominence.</p> <p>Results</p> <p>Primary lymphocytes from patients with well functioning total hip replacements demonstrated a higher incidence and greater magnitude of reactivity to chromium than young healthy controls (p < 0.03). Of the 15 metal ion-challenged subjects with well functioning total hip arthroplasties, 7 demonstrated a proliferative response to Chromium, Nickel, Cobalt and/or Titanium (as defined by a statistically significant >2 fold stimulation index response, p < 0.05) and were designated as metal-reactive. Metals such as Cobalt, Copper, Manganese, and Vanadium were toxic at concentrations as low as 0.5 mM while other metals, such as Aluminum, Chromium, Iron, Molybdenum, and Nickel, became toxic at much higher concentrations (>10 mM). The differential secretion of signature T-cell subsets' cytokines (Th1 and Th2 lymphocytes releasing IFN-gamma and IL-4, respectively) between those total hip arthroplasty subjects which demonstrated metal-reactivity and those that did not, indicated a Th1 type (IFN-gamma) pro-inflammatory response.</p> <p>Conclusion</p> <p>Elevated proliferation and production of IFN-gamma to metals in hip arthroplasty subjects' lymphocytes indicates that a Th1 (vs. Th2) type response is likely associated with any metal induced reactivity. The involvement of an elevated and specific lymphocyte response suggests an <it>adaptive </it>(macrophage recruiting) immunity response to metallic implant debris rather than an <it>innate </it>(nonspecific) immune response.</p

    Analysis of three statistical methods to predict the presence of carotid atheromatous plaques

    Get PDF
    Background: At least 15-20% of all ischemic strokes are attributable to atherosclerosis [1]. We analyzed three statistical methods for 12 traditional risk factors (TRF) i.e. age, sex, arterial pressure, Intima Media Tickness (IMT), Pulse Wave Velocity (PWV) in order to predict the presence of carotid atherosclerotic plaques. Methods: We studied 48 patients (27 men, mean age 52+/-10.9) after a vascular screening for atherosclerosis from a metabolic syndrome cohort in a retrospective way. Fourteen patients presented carotid atheromatous plaques confirmed by a trained operator using an ultrasound system. The sensitivity and specificity of the combination of the IMT and the PWV indices with other risk factors were considered using: multiple linear regressions (MLR), support vector machines (SVM) [2] and discriminant analysis (DA). The best combinations of variables were kept for each learning machine. Results: The best sensibility and specificity were obtained using DA. This method reached a sensitivity of 95+/-7% and a specificity of 73+/-36% with an area under the ROC curve equal to 0.84+/-0.35. The other methods showed a sensitivity of 73+/-13% for the MLR method and 53+/-34% for the SVM method with an area under the ROC curve of 0.72+/-0.07 and 0.74+/-0.18 respectively. Conclusion: This preliminary study shows that carotid atherosclerotic plaques could be reliably predicted using discriminant analysis method. Additional studies are needed to confirm the statistical differences observed using this method and to predict the severity of carotid atherosclerosis

    Bearings in Hip Arthroplasty:Joint Registries vs Precision Medicine: Review Article

    Get PDF
    Background: Precision medicine has been adopted in a range of clinical settings where omics data have led to greater characterisation of disease and stratification of patients into subcategories of phenotypes and pathologies. However, in orthopaedics, precision medicine lags behind other disciplines such as cancer. Joint registries have now amassed a huge body of data pertaining to implant performance which can be broken down into performance statistics for different material types in different cohorts of patients. The National Joint Registry of England, Wales and Northern Ireland (NJR) is now one of the largest datasets available. Other registries such as those from Sweden and Australia however contain longer follow-up. Together, these registries can provide a wealth of informative for the orthopaedics community when considering which implant to give to any particular patient. Questions/Purposes: We aim to explore the benefits of combining multiple large data streams including joint registries, published data on osteoarthritis (OA) pathogenesis and pathology and data concerning performance of each implant material combination in terms of biocompatibility. We believe that this analysis will provide a comprehensive overview of implant performance hopefully aiding surgeons in making more informed choices about which implant should be used in which patient. Methods: Data from three joint registries were combined with established literature to highlight the heterogeneity of OA disease and the different clinical outcomes following arthroplasty with a range of material types. Results: This review confirms that joint registries are unable to consider differences in arthritis presentation or underlying drivers of pathology. OA is now recognised to present with varying pathology with differing morbidity in different patient populations. Equally, just as OA is a heterogeneous disease, there are disparate responses to wear debris from different material combinations used in joint replacement surgery. This has been highlighted by recent high-profile scrutiny of early failure of metal-on-metal total hip replacement (THR) implants. Conclusions: Bringing together data from joint registries, biomarker analysis, phenotyping of OA patients and knowledge of how different patients respond to implant debris will lead to a truly personalised approach to treating OA patients, ensuring that the correct implant is given to the correct patient at the correct time

    Postoperative spinal infection mimicking systemic vasculitis with titanium-spinal implants

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Secondary systemic vasculitis after posterior spinal fusion surgery is rare. It is usually related to over-reaction of immune-system, to genetic factors, toxicity, infection or metal allergies.</p> <p>Case Description</p> <p>A 14 year-old girl with a history of extended posterior spinal fusion due to idiopathic scoliosis presented to our department with diffuse erythema and nephritis (macroscopic hemuresis and proteinuria) 5 months post surgery. The surgical trauma had no signs of inflammation or infection. The blood markers ESR and CRP were increased. Skin tests were positive for nickel allergy, which is a content of titanium alloy. The patient received corticosteroids systematically (hydrocortisone 10 mg) for 6 months, leading to total recess of skin and systemic reaction. However, a palpable mass close to the surgical wound raised the suspicion of a late infection. The patient had a second surgery consisting of surgical debridement and one stage revision of posterior spinal instrumentation. Intraoperative cultures were positive to Staphylococcus aureus. Intravenous antibiotics were administered. The patient is now free of symptoms 24 months post revision surgery without any signs of recurrence of either vasculitis or infection.</p> <p>Literature Review</p> <p>Systemic vasculitis after spinal surgery is exceptionally rare. Causative factors are broad and sometimes controversial. In general, it is associated with allergy to metal ions. This is usually addressed with metal on metal total hip bearings. In spinal surgery, titanium implants are considered to be inert and only few reports have presented cases with systemic vasculitides. Therefore, other etiologies of immune over-reaction should always be considered, such as drug toxicity, infection, or genetic predisposition.</p> <p>Purposes and Clinical Relevance</p> <p>Our purpose was to highlight the difficulties during the diagnostic work-up for systemic vasculitis and management in cases of posterior spinal surgery.</p

    Tribocorrosion behavior of CoCrMo alloy for hip prosthesis as a function of loads: A comparison between two testing systems

    Get PDF
    Metal-on-metal (MOM) hip prosthesis bearings have enjoyed renewed popularity, but concerns remain with wear debris and metal ion release causing a negative response in the surrounding tissues. Further understanding into the wear and corrosion mechanisms occurring in MOM hips is therefore essential. The purpose of this study was to evaluate the tribocorrosion behavior, or interplay between corrosion and wear, of a low-carbon CoCrMo alloy as a function of loading. The tribocorrosion tests were performed using two tribometer configurations. In the first configuration, “System A”, a linearly reciprocating alumina ball slid against the flat metal immersed in a phosphate buffer solution (PBS). In the second configuration, “System B”, the flat end of a cylindrical metal pin was pressed against an alumina ball that oscillated rotationally, using bovine calf serum (BCS) as the lubricant and electrolyte. System B was custom-built to emulate in vivo conditions. The tribocorrosion tests were performed under potentiostatic conditions at −0.345 V, with a sliding duration of 1800 s and a frequency of 1 Hz. In System A the applied loads were 0.05, 0.5, and 1 N (138, 296 and 373 MPa, respectively) and in System B were 16, 32, and 64 N (474, 597, and 752 MPa, respectively). Electrochemical impedance spectroscopy (EIS) and polarization resistance were estimated. The total mass loss (Kwc) in the CoCrMo was determined. The mass loss due to wear (Kw) and that due to corrosion (Kc) were determined. The dominant wear regime for the CoCrMo alloy subjected to sliding changes from wear–corrosion to mechanical wear as the contact stress increases. An attempt was made to compare both system, in their tribochemical responses and formulate some insights in the total degradation processes. Our results also suggest that the proteins in the serum lubricant assist in the generation of a protective layer against corrosion during sliding. The study highlights the need of adequate methodology/guidelines to compare the results from different test systems and translating in solving the practical problems
    corecore