538 research outputs found

    The End Magnets of the Ifusp Race-track Microtron Booster

    Get PDF
    The end magnets of the IFUSP race-track microtron booster, second stage of the electron accelerator under construction at the Linear Accelerator Laboratory, are presented. They deflect, focus and return the beam to the accelerating section. Details about the project are discussed, Poisson code was used to give the final geometry of the end magnets. The end magnets incorporate auxiliary pole pieces (clamps) which create a reverse fringe field region that avoids the beam vertical defocusing and reduces the horizontal displacement produced by extended fringe fields (EFF). The small gap height used for the clamps provided reverse field distributions with fringe fields of short extensions, avoiding the traditional use of inactive clamps. Measurements and calculations concerning particle trajectories and reverse field distribution are presented. The floating wire technique, employing an original procedure to register orbits, was used to corroborate the calculated beam trajectories and represents a good experimental option in the lack of the accelerator beam. The experimental results showed agreement of about 0.1% with the calculations

    Diagnosis and workup of 522 consecutive patients with neuroendocrine neoplasms in Switzerland.

    Get PDF
    BACKGROUND: Neuroendocrine neoplasms (NENs) are difficult to diagnose. We used SwissNET data to characterise NEN patients followed in the two academic centres of western Switzerland (WS), and to compare them with patients followed in eastern Switzerland (ES) as well as with international guidelines. METHOD: SwissNET is a prospective database covering data from 522 consecutive patients (285 men, 237 women) from WS (n = 99) and ES (n = 423). RESULTS: Mean ± SD age at diagnosis was 59.0 ± 15.7 years. Overall, 76/522 experienced a functional syndrome, with a median interval of 1.0 (IQR: 1.0-3.0) year between symptoms onset and diagnosis. A total of 51/522 of these tumours were incidental. The primary tumour site was the small intestine (29%), pancreas (21%), appendix (18%) and lung (11%) in both regions combined. In all, 513 functional imaging studies were obtained (139 in WS, 374 in ES). Of these, 381 were 111In-pentetreotide scintigraphies and 20 were 68Ga-DOTATOC PET. First line therapy was surgery in 87% of patients, medical therapy (biotherapy or chemotherapy) in 9% and irradiation in 3% for both regions together. CONCLUSION: Swiss NEN patients appear similar to what has been described in the literature. Imaging by somatostatin receptor scintigraphy (SRS) is widely used in both regions of Switzerland. In good accordance with published guidelines, data on first line therapy demonstrate the crucial role of surgery. The low incidence of biotherapy suggests that long-acting somatostatin analogues are not yet widely used for their anti-proliferative effects. The SwissNET initiative should help improve compliance with ENETS guidelines in the workup and care of NEN patients

    The Brand Development Strategy Research of Lilanz Garment Enterprise

    Get PDF
    随着经济全球化的迅速发展和现代科学技术的不断进步,世界已进入品牌竞争时代。品牌成为衡量一个国家综合经济实力的重要标志。而在这样一个极速变化的市场条件下,在消费者消费观念、消费行为不断变化的背景下,企业如何打造基于消费需求的品牌发展战略,就成为任何一个企业能够在新的市场竞争中立足并获得竞争优势的关键。 改革开放以来,我国服装工业得到迅猛发展,在满足需求、繁荣市场、争创外汇、增加税收、安排就业等方面,为国民经济的发展做出了很大贡献。作为中国最重要的服装生产基地和品牌聚集地,泉州服装产业已经得到了快速发展,形成了从上游的纺织、染整,到下游的成衣制造,再到配套原辅材料的完整产业链和以低成本扩张的低端...With the rapid development of economic globalization and advancement of modern science and technology, the world has entered the era of brand competition. Brand as a measure of a country's overall economic strength of the regiment. In such a speed changing market conditions,the consumer concept of consumption, consumer behavior changing context of consumer demand for enterprises to build on the br...学位:工商管理硕士院系专业:管理学院高级经理教育中心(EMBA项目)_高级管理人员工商管理硕士(EMBA)学号:X200615611

    Beam-Based Alignment of the NuMI Target Station Components at FNAL

    Get PDF
    The Neutrinos at the Main Injector (NuMI) facility is a conventional horn-focused neutrino beam which produces muon neutrinos from a beam of mesons directed into a long evacuated decay volume. The relative alignment of the primary proton beam, target, and focusing horns affects the neutrino energy spectrum delivered to experiments. This paper describes a check of the alignment of these components using the proton beam.Comment: higher resolution figures available on Fermilab Preprint Server (see SPIRES entry), accepted for publication in Nucl. Instr. and Meth.

    Search for the Rare Decays KL->pi0pi0mu+mu- and KL->pi0pi0X0->pi0pi0mu+mu-

    Full text link
    The KTeV E799 experiment has conducted a search for the rare decays KL->pi0pi0mu+mu- and KL->pi0pi0X0->pi0pi0mu+mu-, where the X0 is a possible new neutral boson that was reported by the HyperCP experiment with a mass of (214.3 pm 0.5) MeV/c^{2}. We find no evidence for either decay. We obtain upper limits of Br(KL->pi0pi0X0->pi0pi0mu+mu-) pi0pi0mu+mu-) < 9.2 x 10^{-11} at the 90% confidence level. This result rules out the pseudoscalar X0 as an explanation of the HyperCP result under the scenario that the \bar{d}sX0 coupling is completely real

    Search for the Rare Decay K_{L}\to\pi^{0}\pi^{0}\gamma

    Full text link
    The KTeV E799 experiment has conducted a search for the rare decay KLπ0π0γK_{L}\to\pi^{0}\pi^{0}\gamma via the topology KLπ0πD0γK_{L}\to\pi^{0}\pi^{0}_D\gamma (where πD0γe+e\pi^0_D\to\gamma e^+e^-). Due to Bose statistics of the π0\pi^0 pair and the real nature of the photon, the KLπ0π0γK_{L}\to\pi^{0}\pi^{0}\gamma decay is restricted to proceed at lowest order by the CP conserving direct emission (DE) of an E2 electric quadrupole photon. The rate of this decay is interesting theoretically since chiral perturbation theory predicts that this process vanishes at level O(p4)O(p^4). Therefore, this mode probes chiral perturbation theory at O(p6)O(p^6). In this paper we report a determination of an upper limit of 2.43×1072.43\times 10^{-7} (90% CL) for KLπ0π0γK_{L}\to\pi^{0}\pi^{0}\gamma. This is approximately a factor of 20 lower than previous results.Comment: six pages and six figures in the submission. Reformatted for Physics Review

    Determination of the Parity of the Neutral Pion via the Four-Electron Decay

    Full text link
    We present a new determination of the parity of the neutral pion via the double Dalitz decay pi^0 -> e+ e- e+ e-. Our sample, which consists of 30511 candidate decays, was collected from K_L -> pi0 pi0 pi0 decays in flight at the KTeV-E799 experiment at Fermi National Accelerator Laboratory. We confirm the negative pi^0 parity, and place a limit on scalar contributions to the pi^0 -> e+ e- e+ e- decay amplitude of less than 3.3% assuming CPT conservation. The pi^0 gamma* gamma* form factor is well described by a momentum-dependent model with a slope parameter fit to the final state phase space distribution. Additionally, we have measured the branching ratio of this mode to be B(pi^0 -> e+ e- e+ e-) = (3.26 +- 0.18) x 10^(-5).Comment: 5 pages, 4 figures. Typographical error in radiative branching ratio (Eq. 6) correcte

    A Measurement of the K0 Charge Radius and a CP Violating Asymmetry Together with a Search for CP Violating E1 Direct Photon Emission in the Rare Decay KL->pi+pi-e+e-

    Full text link
    Using the complete KTeV data set of 5241 candidate KL->pi+pi-e+e- decays (including an estimated background of 204+-14 events), we have measured the coupling gCR=0.163+- 0.014(stat)+-0.023(syst) of the CP conserving charge radius process and from it determined a K0 charge radius of (K0)=(-0.077+-0.007(stat)+-0.011(syst)) fm**2. We have also determined a first experimental upper limit of 0.04 (90% CL) for the ratio |g_{E1}|/|g_{M1}| of the coupling for the E1 direct photon emission process relative to the coupling for M1 direct photon emission process. We also report the measurement of its associated vector form factor |gM1`|(1+ (a_1/a_2)/(M(rho)**2-M(K)**2)+2M(K)E(gamma*)) where |gM1`|=(1.11+- 0.12(stat)+-0.08(syst) and a_1/a_2 = (-0.744+-0.027(stat)0.032(syst)) GeV**2/c**2. In addition, a measurement of the manifestly CP violating asymmetry of magnitude (13.6+- 1.4+-(stat)+-1.5(syst))% in the CP and T odd angle phi between the decay planes of the e+e- and pi+pi- pairs in the KL center of mass system is reported

    Dispersive analysis of K_{L mu3} and K_{L e3} scalar and vector form factors using KTeV data

    Get PDF
    Using the published KTeV samples of K_L --> pi^{\pm} e^{\mp} nu and K_L --> pi^{\pm} mu^{\mp} nu decays [1], we perform a reanalysis of the scalar and vector form factors based on the dispersive parameterization [2,3]. We obtain phase space integrals I^e_K = 0.15446 \pm 0.00025 and I^{mu}_K = 0.10219 \pm 0.00025. For the scalar form factor parameterization, the only free parameter is the normalized form factor value at the Callan-Treiman point (C); our best fit results in ln C = 0.1915 \pm 0.0122. We also study the sensitivity of C to different parametrizations of the vector form factor. The results for the phase space integrals and C are then used to make tests of the Standard Model. Finally, we compare our results with lattice QCD calculations of F_K/F_pi and f_+(0).Comment: 9 pages, 3 figures, to be published in PR

    Detailed Study of the KL -> 3pi0 Dalitz Plot

    Get PDF
    Using a sample of 68 million KL -> 3pi0 decays collected in 1996-1999 by the KTeV (E832) experiment at Fermilab, we present a detailed study of the KL -> 3pi0 Dalitz plot density. We report the first observation of interference from KL->pi+pi-pi0 decays in which pi+pi- rescatters to 2pi0 in a final-state interaction. This rescattering effect is described by the Cabibbo-Isidori model, and it depends on the difference in pion scattering lengths between the isospin I=0 and I=2 states, a0-a2. Using the Cabibbo-Isidori model, we present the first measurement of the KL-> 3pi0 quadratic slope parameter that accounts for the rescattering effect.Comment: accepted by Phys. Rev
    corecore