1,719 research outputs found

    Rare quantum metastable states in the strongly dispersive Jaynes-Cummings oscillator

    Get PDF
    We present evidence of metastable rare quantum-fluctuation switching for the driven dissipative Jaynes-Cummings oscillator coupled to a zero-temperature bath in the strongly dispersive regime. We show that single-atom complex amplitude bistability is accompanied by the appearance of a low-amplitude long-lived transient state, hereinafter called `dark state', having a distribution with quasi-Poissonian statistics both for the coupled qubit and cavity mode. We find that the dark state is linked to a spontaneous flipping of the qubit state, detuning the cavity to a low-photon response. The appearance of the dark state is correlated with the participation of the two metastable states in the dispersive bistability, as evidenced by the solution of the Master Equation and single quantum trajectories.Comment: Extensively revised text, 18 revised figures (16 in main and 2 in appendix), 38(+1) references, appendi

    C Wright Mills, power and the power elites ? a reappraisal

    Get PDF
    This paper revisits and presents a critical appraisal of Mills's analysis of power and the power elite. There are signs of a revival of interest in Mills, but recent commentators have shown little interest in the intellectual, social or political context of his analysis. Setting Mills's thesis in its historical context, we consider an element of his project that has been particularly neglected in recent discussion: Mills's search for possible ways of redistributing power and his attempt to forge an ethico-political stance. Reflecting on recent discussion of contemporary elite formations, we comment on what critics might take from Mills in our own time in relation to the analysis of elites and the politics of critical management studies

    Rayleigh-B\'{e}nard convection in a homeotropically aligned nematic liquid crystal

    Full text link
    We report experimental results for convection near onset in a thin layer of a homeotropically aligned nematic liquid crystal heated from below as a function of the temperature difference ΔT\Delta T and the applied vertical magnetic field HH and compare them with theoretical calculations. The experiments cover the field range 8 \alt h \equiv H/ H_{F} \alt 80 (HF=H_F = is the Fr\'eedericksz field). For hh less than a codimension-two field hct≃46h_{ct} \simeq 46 the bifurcation is subcritical and oscillatory, with travelling- and standing-wave transients. Beyond hcth_{ct} the bifurcation is stationary and subcritical until a tricritical field ht=57.2h_t= 57.2 is reached, beyond which it is supercritical. The bifurcation sequence as a function of hh found in the experiment confirms the qualitative aspects of the theoretical predictions. However, the value of hcth_{ct} is about 10% higher than the predicted value and the results for kck_c are systematically below the theory by about 2% at small hh and by as much as 7% near hcth_{ct}. At hcth_{ct}, kck_c is continuous within the experimental resolution whereas the theory indicates a 7% discontinuity. The theoretical tricritical field htth=51h_t^{th} = 51 is somewhat below the experimental one. The fully developed flow above RcR_c for h<hcth < h_{ct} is chaotic. For hct<h<hth_{ct} < h < h_t the subcritical stationary bifurcation also leads to a chaotic state. The chaotic states persist upon reducing the Rayleigh number below RcR_c, i.e. the bifurcation is hysteretic. Above the tricritical field hth_t, we find a bifurcation to a time independent pattern which within our resolution is non-hysteretic.Comment: 15 pages incl. 23 eps figure

    Assortative roosting in the two phonic types of Pipistrellus pipistrellus during the mating season

    Get PDF
    The European pipistrelle, Pipistrellus pipistrellus, consists of two phonic types that echolocate with frequencies of maximum energy (FMAXE) averaging 46 kHz and 55 kHz (named the 45 kHz and 55 kHz phonic types for simplicity). These two phonic types occur in sympatry over much of Britain. Between 1993 and 1995 mating groups of P. pipistrellus were located in bat boxes between August and October, the main mating period for these bats. Mating groups comprised a single male and up to three females. Broadband, time-expanded recordings of search-phase echolocation calls were made from bats immediately after release. The average FMAXE of each bat was calculated: bats with an FMAXE less than 49 kHz were classed as 45 kHz phonic types and bats with an FMAXE greater than 52 kHz were classed as 55 kHz phonic types. A total of 16, 45 kHz groups and ten 55 kHz groups were located. No mating group ever contained more than one phonic type, although both types were known to be present at several of the study sites. Males emitted calls of higher frequency than females for both phonic types. The study suggests that the two phonic types are reproductively isolated and supports the hypothesis that P. pipistrellus should be considered as two cryptic sibling species

    Automatic segmentation of prostate MRI using convolutional neural networks: Investigating the impact of network architecture on the accuracy of volume measurement and MRI-ultrasound registration

    Get PDF
    Convolutional neural networks (CNNs) have recently led to significant advances in automatic segmentations of anatomical structures in medical images, and a wide variety of network architectures are now available to the research community. For applications such as segmentation of the prostate in magnetic resonance images (MRI), the results of the PROMISE12 online algorithm evaluation platform have demonstrated differences between the best-performing segmentation algorithms in terms of numerical accuracy using standard metrics such as the Dice score and boundary distance. These small differences in the segmented regions/boundaries outputted by different algorithms may potentially have an unsubstantial impact on the results of downstream image analysis tasks, such as estimating organ volume and multimodal image registration, which inform clinical decisions. This impact has not been previously investigated. In this work, we quantified the accuracy of six different CNNs in segmenting the prostate in 3D patient T2-weighted MRI scans and compared the accuracy of organ volume estimation and MRI-ultrasound (US) registration errors using the prostate segmentations produced by different networks. Networks were trained and tested using a set of 232 patient MRIs with labels provided by experienced clinicians. A statistically significant difference was found among the Dice scores and boundary distances produced by these networks in a non-parametric analysis of variance (p < 0.001 and p < 0.001, respectively), where the following multiple comparison tests revealed that the statistically significant difference in segmentation errors were caused by at least one tested network. Gland volume errors (GVEs) and target registration errors (TREs) were then estimated using the CNN-generated segmentations. Interestingly, there was no statistical difference found in either GVEs or TREs among different networks, (p = 0.34 and p = 0.26, respectively). This result provides a real-world example that these networks with different segmentation performances may potentially provide indistinguishably adequate registration accuracies to assist prostate cancer imaging applications. We conclude by recommending that the differences in the accuracy of downstream image analysis tasks that make use of data output by automatic segmentation methods, such as CNNs, within a clinical pipeline should be taken into account when selecting between different network architectures, in addition to reporting the segmentation accuracy

    Restriction enzyme digestion of host DNA enhances universal detection of parasitic pathogens in blood via targeted amplicon deep sequencing.

    Full text link
    BACKGROUND: Targeted amplicon deep sequencing (TADS) of the 16S rRNA gene is commonly used to explore and characterize bacterial microbiomes. Meanwhile, attempts to apply TADS to the detection and characterization of entire parasitic communities have been hampered since conserved regions of many conserved parasite genes, such as the 18S rRNA gene, are also conserved in their eukaryotic hosts. As a result, targeted amplification of 18S rRNA from clinical samples using universal primers frequently results in competitive priming and preferential amplification of host DNA. Here, we describe a novel method that employs a single pair of universal primers to capture all blood-borne parasites while reducing host 18S rRNA template and enhancing the amplification of parasite 18S rRNA for TADS. This was achieved using restriction enzymes to digest the 18S rRNA gene at cut sites present only in the host sequence prior to PCR amplification. RESULTS: This method was validated against 16 species of blood-borne helminths and protozoa. Enzyme digestion prior to PCR enrichment and Illumina amplicon deep sequencing led to a substantial reduction in human reads and a corresponding 5- to 10-fold increase in parasite reads relative to undigested samples. This method allowed for discrimination of all common parasitic agents found in human blood, even in cases of multi-parasite infection, and markedly reduced the limit of detection in digested versus undigested samples. CONCLUSIONS: The results herein provide a novel methodology for the reduction of host DNA prior to TADS and establish the validity of a next-generation sequencing-based platform for universal parasite detection

    Technical Note: Error metrics for estimating the accuracy of needle/instrument placement during transperineal MR/US-guided prostate interventions

    Get PDF
    Purpose: Image-guided systems that fuse magnetic resonance imaging (MRI) with three-dimensional (3D) ultrasound (US) images for performing targeted prostate needle biopsy and minimally-invasive treatments for prostate cancer are of increasing clinical interest. To date, a wide range of different accuracy estimation procedures and error metrics have been reported, which makes comparing the performance of different systems difficult. Methods: A set of 9 measures are presented to assess the accuracy of MRI-US image registration, needle positioning, needle guidance, and overall system error, with the aim of providing a methodology for estimating the accuracy of instrument placement using a MR/US-guided transperineal approach. Results: Using the SmartTarget fusion system, an MRI-US image alignment error was determined to be 2.0±1.0 mm (mean ± SD), and an overall system instrument targeting error of 3.0±1.2 mm. Three needle deployments for each target phantom lesion was found to result in a 100% lesion hit rate and a median predicted cancer core length of 5.2 mm. Conclusions: The application of a comprehensive, unbiased validation assessment for MR/TRUS guided systems can provide useful information on system performance for quality assurance and system comparison. Furthermore, such an analysis can be helpful in identifying relationships between these errors, providing insight into the technical behaviour of these systems

    Measured and modelled corner diffraction at millimetre wave frequencies

    Get PDF
    • …
    corecore