158 research outputs found

    Modeling of a spiral-wound reverse osmosis process and parameter estimation

    Get PDF
    YesReverse osmosis system has been widely used for the separation of organic and non-organic pollutants present in wastewater. The main aim of this study is to develop a one dimensional steady state model based on the three-parameter Spiegler-Kedem methodology using the gPROMS software and validate it by assessing the performance of membrane rejection for the separation data of aqueous solutions of phenol under different concentrations and pressures. Considerations of the variance of pressure, flow rate, solute concentration, solvent and solute fluxes and mass transfer coefficient along the feed channel were included in the model. Furthermore, an optimization methodology for the gEST parameter estimation tool has been developed in the gPROMS and used with experimental data in order to estimate the best values of the separation membrane parameters and the friction parameter. The simulation results of this model have been corroborated by experimental data

    Barriers to the practice of exclusive breastfeeding among HIV-positive mothers in sub-Saharan Africa: A scoping review of counselling, socioeconomic and cultural factors

    Get PDF
    The World Health Organization (WHO) recommends exclusive breast-feeding (EBF) for HIV exposed infants for six months; this is considered best practice for reducing mother-to-child transmission of HIV in the postpartum period. This is a scoping review of the barriers affecting women's decision-making and choice to sustain the practice of EBF in sub-Saharan Africa (SSA). An online literature search via PubMed, Science Direct, Google Scholar, WHO and Joint United Nations programme on HIV and AIDS (UNAIDS) websites identified research studies and reports that explored socio-economic, cultural and infant feeding counselling-related barriers to EBF among HIV-positive mothers in SSA. A total of 341 relevant articles were identified only 35 (23 qualitative, 3 quantitative and 9 mixed methods) met the inclusion criteria. Findings reveal that key barriers to choice and sustained practice of EBF are healthcare workers’ personal biases, inadequate counselling skills and guideline knowledge, a culture of mixed feeding norms, and maternal lack of decision-making power and fear of vertical transmission. Transmission of HIV programs in countries where major challenges persist should evaluate and address the identified healthcare worker and community-level factors impeding EBF

    Optimal reverse osmosis network configuration for the rejection of dimethylphenol from wastewater

    Get PDF
    YesReverse osmosis (RO) has long been recognised as an efficient separation method for treating and removing harmful pollutants, such as dimethylphenol in wastewater treatment. This research aims to study the effects of RO network configuration of three modules of a wastewater treatment system using a spiral-wound RO membrane for the removal of dimethylphenol from its aqueous solution at different feed concentrations. The methodologies used for this research are based on simulation and optimisation studies carried out using a new simplified model. This takes into account the solution-diffusion model and film theory to express the transport phenomena of both solvent and solute through the membrane and estimate the concentration polarization impact respectively. This model is validated by direct comparison with experimental data derived from the literature and which includes dimethylphenol rejection method performed on a small-scale commercial single spiral-wound RO membrane system at different operating conditions. The new model is finally implemented to identify the optimal module configuration and operating conditions that achieve higher rejection after testing the impact of RO configuration. The optimisation model has been formulated to maximize the rejection parameters under optimal operating conditions of inlet feed flow rate, pressure and temperature for a given set of inlet feed concentration. Also, the optimisation model has been subjected to a number of upper and lower limits of decision variables, which include the inlet pressure, flow rate and temperature. In addition, the model takes into account the pressure loss constraint along the membrane length commensurate with the manufacturer’s specifications. The research clearly shows that the parallel configuration yields optimal dimethylphenol rejection with lower pressure loss

    Cost evaluation and optimisation of hybrid multi effect distillation and reverse osmosis system for seawater desalination

    Get PDF
    YesIn this research, the effect of operating parameters on the fresh water production cost of hybrid Multi Effect Distillation (MED) and Reverse Osmosis (RO) system is investigated. To achieve this, an earlier comprehensive model developed by the authors for MED + RO system is combined with two full-scale cost models of MED and RO processes collected from the literature. Using the economic model, the variation of the overall fresh water cost with respect to some operating conditions, namely steam temperature and steam flow rate for the MED process and inlet pressure and flow rate for the RO process, is accurately investigated. Then, the hybrid process model is incorporated into a single-objective non-linear optimisation framework to minimise the fresh water cost by finding the optimal values of the above operating conditions. The optimisation results confirm the economic feasibility of the proposed hybrid seawater desalination plant

    Design and economic evaluation of solar-powered hybrid multi effect and reverse osmosis system for seawater desalination

    Get PDF
    YesReducing the cost of fresh water has always been a major concern in the desalination industry. A solar powered hybrid multi-effect distillation and reverse osmosis desalination plant (MED+RO) has been designed and optimised from an economical point of view in a previous work by the same authors. In the present study, the possibility of coupling the desalination plant with a photovoltaic (PV) solar farm is investigated, with the aim of generating electricity at low cost and in a sustainable way. A detailed mathematical model for the PV system has been implemented from the literature. Interestingly, the model can predict the cost of the PV system in terms of capital cost and electricity cost per kWh considering the input data of solar irradiation, duration of daylight and technical specification of a real solar module. Consequently, the solar PV model has been combined with the desalination model, which enables to estimate the cost of fresh water per cubic meter. Data about four locations, namely Isola di Pantelleria (IT), Las Palmas (ES), Abu Dhabi (UAE), and Perth (AUS), have been used to economically test the feasibility of installing the proposed plant, and especially of the PV solar farm

    Numerical modelling and sensitivity analysis of natural draft cooling towers

    Get PDF
    YesCooling towers are a relatively inexpensive and consistent method of ejecting heat from several industries such as thermal power plants, refineries, and food processing. In this research, an earlier model from literature was to be validated across three different case studies. Unlike previous models, this model considers the height of the fill as the discretised domain, which produces results that give it in a distribution form along the height of the tower. As there are limitations with the software used (gPROMS) where differential equations with respect to independent variables in the numerator and denominator cannot be solved, a derivative of the saturation vapour pressure with respect to the temperature of the air was presented. Results shown were in agreement with the literature and a parametric sensitivity analysis of the cooling tower design and operating parameters were undertaken. In this work the height of fill, mass flowrates of water and air were studied with respect to sensitivity analysis. Results had shown large variations in the outlet temperatures of the water and air if the mass flows of water and air were significantly reduced. However, upon high values of either variable had shown only small gains in the rejection of heat from the water stream. With respect to the height of the fill, at larger heights of the fill, the outlet water temperature had reduced significantly. From a cost perspective, it was found that a change in the water flowrate had incurred the largest cost penalty with a 1% increase in flowrate had increased the average operating cost by 1.2%. In comparison, a change in air flowrate where a 1% increase in flowrate had yielded an average of 0.4% increase in operating cost
    • …
    corecore