302 research outputs found

    Self-Assembly of Supramolecular Triblock Copolymer Complexes

    Get PDF
    Four different poly(tert-butoxystyrene)-b-polystyrene-b-poly(4-vinylpyridine) (PtBOS-b-PS-b-P4VP) linear triblock copolymers, with the P4VP weight fraction varying from 0.08 to 0.39, were synthesized via sequential anionic polymerization. The values of the unknown interaction parameters between styrene and tert-butoxystyrene and between tert-butoxystyrene and 4-vinylpyridine were determined from random copolymer blend miscibility studies and found to satisfy 0.031<χS,tBOS<0.034 and 0.39<χ4VP,tBOS<0.43, the latter being slightly larger than the known 0.30<χS,4VP≀0.35 value range. All triblock copolymers synthesized adopted a P4VP/PS core/shell cylindrical self-assembled morphology. From these four triblock copolymers supramolecular complexes were prepared by hydrogen bonding a stoichiometric amount of pentadecylphenol (PDP) to the P4VP blocks. Three of these complexes formed a triple lamellar ordered state with additional short length scale ordering inside the P4VP(PDP) layers. The self-assembled state of the supramolecular complex based on the triblock copolymer with the largest fraction of P4VP consisted of alternating layers of PtBOS and P4VP(PDP) layers with PS cylinders inside the latter layers. The difference in morphology between the triblock copolymers and the supramolecular complexes is due to two effects: (i) a change in effective composition and, (ii) a reduction in interfacial tension between the PS and P4VP containing domains. The small angle X-ray scattering patterns of the supramolecules systems are very temperature sensitive. A striking feature is the disappearance of the first order scattering peak of the triple lamellar state in certain temperature intervals, while the higher order peaks (including the third order) remain. This is argued to be due to the thermal sensitivity of the hydrogen bonding and thus directly related to the very nature of these systems.

    Results from the intercalibration of optical low light calibration sources 2011

    Get PDF
    Following the 38th Annual European Meeting on Atmospheric Studies by Optical Methods in Siuntio in Finland, an intercalibration workshop for optical low light calibration sources was held in SodankylĂ€, Finland. The main purpose of this workshop was to provide a comparable scale for absolute measurements of aurora and airglow. All sources brought to the intercalibration workshop were compared to the Fritz Peak reference source using the Lindau Calibration Photometer built by Wilhelm Barke and Hans Lauche in 1984. The results were compared to several earlier intercalibration workshops. It was found that most sources were fairly stable over time, with errors in the range of 5–25%. To further validate the results, two sources were also intercalibrated at UNIS, Longyearbyen, Svalbard. Preliminary analysis indicates agreement with the intercalibration in SodankylĂ€ within about 15–25%

    Using models of the ocean's mean dynamic topography to identify errors in coastal geodetic levelling

    Get PDF
    Identifying errors (blunders and systematic errors) in coastal geodetic levelling networks has often been problematic. This is because (1) mean sea level (MSL) at tide gauges cannot be directly compared to height differences from levelling because the geoid/quasigeoid and MSL are not parallel, being separated by the ocean’s mean dynamic topography (MDT) and (2) the lack of redundancy at the edge of the levelling network. This paper sets out a methodology to independently identify blunders and/or systematic errors (over long distances) in geodetic levelling using MDT models to account for the separation between the geoid/quasigeoid and MSL at tide gauges. This method is then tested in a case study using an oceanographic MDT model, MSL observations, GNSS data and a quasigeoid model. The results are significant because the errors found could not be detected by standard levelling misclosure checks alone, with supplementary data from an MDT model, with cross-validation from GNSS-quasigeoid allowing their detection. In addition, it appears that an oceanographic-only MDT is as effective as GNSS and a quasigeoid model for detecting levelling errors, which could be particularly useful for countries with coastal levelling errors in their levelling networks that cannot be identified by conventional levelling closure checks

    Vascular responses of the extremities to transdermal application of vasoactive agents in Caucasian and African descent individuals

    Get PDF
    This is an accepted manuscript of an article published by Springer in European Journal of Applied Physiology on 04/04/2015, available online: https://doi.org/10.1007/s00421-015-3164-2 The accepted version of the publication may differ from the final published version.© 2015, Springer-Verlag Berlin Heidelberg. Purpose: Individuals of African descent (AFD) are more susceptible to non-freezing cold injury than Caucasians (CAU) which may be due, in part, to differences in the control of skin blood flow. We investigated the skin blood flow responses to transdermal application of vasoactive agents. Methods: Twenty-four young males (12 CAU and 12 AFD) undertook three tests in which iontophoresis was used to apply acetylcholine (ACh 1 w/v %), sodium nitroprusside (SNP 0.01 w/v %) and noradrenaline (NA 0.5 mM) to the skin. The skin sites tested were: volar forearm, non-glabrous finger and toe, and glabrous finger (pad) and toe (pad). Results: In response to SNP on the forearm, AFD had less vasodilatation for a given current application than CAU (P = 0.027–0.004). ACh evoked less vasodilatation in AFD for a given application current in the non-glabrous finger and toe compared with CAU (P = 0.043–0.014) with a lower maximum vasodilatation in the non-glabrous finger (median [interquartile], AFD n = 11, 41[234] %, CAU n = 12, 351[451] %, P = 0.011) and non-glabrous toe (median [interquartile], AFD n = 9, 116[318] %, CAU n = 12, 484[720] %, P = 0.018). ACh and SNP did not elicit vasodilatation in the glabrous skin sites of either group. There were no ethnic differences in response to NA. Conclusion: AFD have an attenuated endothelium-dependent vasodilatation in non-glabrous sites of the fingers and toes compared with CAU. This may contribute to lower skin temperature following cold exposure and the increased risk of cold injuries experienced by AFD.Published versio

    A dissociative fluorescence enhancement technique for one-step time-resolved immunoassays

    Get PDF
    The limitation of current dissociative fluorescence enhancement techniques is that the lanthanide chelate structures used as molecular probes are not stable enough in one-step assays with high concentrations of complexones or metal ions in the reaction mixture since these substances interfere with lanthanide chelate conjugated to the detector molecule. Lanthanide chelates of diethylenetriaminepentaacetic acid (DTPA) are extremely stable, and we used EuDTPA derivatives conjugated to antibodies as tracers in one-step immunoassays containing high concentrations of complexones or metal ions. Enhancement solutions based on different ÎČ-diketones were developed and tested for their fluorescence-enhancing capability in immunoassays with EuDTPA-labelled antibodies. Characteristics tested were fluorescence intensity, analytical sensitivity, kinetics of complex formation and signal stability. Formation of fluorescent complexes is fast (5 min) in the presented enhancement solution with EuDTPA probes withstanding strong complexones (ethylenediaminetetra acetate (EDTA) up to 100 mM) or metal ions (up to 200 ΌM) in the reaction mixture, the signal is intensive, stable for 4 h and the analytical sensitivity with Eu is 40 fmol/L, Tb 130 fmol/L, Sm 2.1 pmol/L and Dy 8.5 pmol/L. With the improved fluorescence enhancement technique, EDTA and citrate plasma samples as well as samples containing relatively high concentrations of metal ions can be analysed using a one-step immunoassay format also at elevated temperatures. It facilitates four-plexing, is based on one chelate structure for detector molecule labelling and is suitable for immunoassays due to the wide dynamic range and the analytical sensitivity

    Stres na radu i zdravlje medicinskih sestara u jedinicama intenzivne njege u Srbiji

    Get PDF
    The aim of this study was to identify and analyse professional stressors, evaluate the level of stress in nurses in Intensive Care Units (ICU), and assess the correlation between the perception of stress and psychological and somatic symptoms or diseases shown by nurses. The research, designed as a crosssectional study, was carried out in the Intensive Care Units (ICU), in health centres in Serbia. The sample population encompassed 1000 nurses. Expanded Nursing Stress Scale (ENSS) was used as the research instrument. ENSS revealed a valid metric characteristic within our sample population. Nurses from ICUs rated situations involving physical and psychological working environments as the most stressful ones, whereas situations related to social working environment were described as less stressful; however, the differences in the perception of stressfulness of these environments were minor. Socio-demographic determinants of the participants (age, marital status and education level) significantly affected the perception of stress at work. Significant differences in the perception of stressfulness of particular stress factors were observed among nurses with respect to psychological and somatic symptoms (such as headache, insomnia, fatigue, despair, lower back pain, mood swings etc.) and certain diseases (such as hypertension, myocardial infarction, stroke, diabetes mellitus etc). In view of permanent escalation of professional stressors, creating a supportive working environment is essential for positive health outcomes, prevention of job-related diseases and better protection of already ill nurses.Cilj je ovoga rada bio identifi cirati i analizirati profesionalne stresore, procijeniti razinu stresa kod medicinskih sestara u jedinicama intenzivne njege te procijeniti korelaciju između percepcije stresa i prisutnosti psiholoĆĄkih i somatskih simptoma ili bolesti kod medicinskih sestara. IstraĆŸivanje je provedeno u obliku studije presjeka u Jedinicama intenzivne njege u zdravstvenim centrima u Srbiji. Uzorak se sastojao od 1000 medicinskih sestara-tehničara. Za procjenu i analizu profesionalnih stresora koriĆĄten je upitnik Expanded Nursing Stress Scale (ENSS), koji je pokazao validne metrijske karakteristike na naĆĄoj ispitanoj populaciji. Medicinske sestre u Jedinicama intenzivne njege ocijenile su situacije iz fizičkoga i psiholoĆĄkoga radnog okruĆŸenja kao izrazito opterećujuće, a situacije iz socijalnoga radnog okruĆŸenja kao manje opterećujuće. Razlika u percepciji stresogenosti navedenih radnih okruĆŸenja nije bila statistički značajna. Sociodemografske determinante ispitanika (dob, bračno stanje i stupanj obrazovanja) značajno utječu na percepciju stresa na radnom mjestu. Utvrđena je statistički značajna razlika u opaĆŸanju stresogenosti pojedinih stresnih situacija na radnom mjestu između medicinskih sestara u odnosu na postojanje psihosomatskih simptoma (kao ĆĄto su glavobolja, nesanica, umor, očaj, bol u leđima, česte promjene raspoloĆŸenja) ili određenih bolesti (kao ĆĄto su poviĆĄena hipertenzija, infarkt miokarda, cerebrovaskularni inzult, ĆĄećerna bolest). Zbog sve izraĆŸenije prisutnosti profesionalnih stresora nuĆŸno je poduzeti određene strateĆĄke mjere kod medicinskih sestara u Jedinicama intenzivne njege. StrateĆĄke mjere podrazumijevaju unaprjeđenje psihosocijalne radne klime, ĆĄto bi unaprijedilo njihovo zdravlje i spriječilo nastanak bolesti u svezi s radom, ali i omogućilo bolju zaĆĄtitu već oboljelim medicinskim sestrama
    • 

    corecore