831 research outputs found

    Variability of disk emission in pre-main sequence and related stars. II. Variability in the gas and dust emission of the Herbig Fe star SAO 206462

    Get PDF
    This is the author accepted manuscript. The final version is available from the publisher via the DOI in this record.We present 13 epochs of near-infrared (0.8-5 μm) spectroscopic observations of the pre-transitional, "gapped" disk system in SAO 206462 (=HD 135344B). In all, six gas emission lines (Brα, Brγ, Paβ, Paγ, Paδ, Paepsilon, and the 0.8446 μm line of O I) along with continuum measurements made near the standard J, H, K, and L photometric bands were measured. A mass accretion rate of approximately 2 × 10–8 M ☉ yr–1 was derived from the Brγ and Paβ lines. However, the fluxes of these lines varied by a factor of over two during the course of a few months. The continuum also varied, but by only ~30%, and even decreased at a time when the gas emission was increasing. The H I line at 1.083 μm was also found to vary in a manner inconsistent with that of either the hydrogen lines or the dust. Both the gas and dust variabilities indicate significant changes in the region of the inner gas and the inner dust belt that may be common to many young disk systems. If planets are responsible for defining the inner edge of the gap, they could interact with the material on timescales commensurate with what is observed for the variations in the dust, while other disk instabilities (thermal, magnetorotational) would operate there on longer timescales than we observe for the inner dust belt. For SAO 206462, the orbital period would likely be 1-3 years. If the changes are being induced in the disk material closer to the star than the gap, a variety of mechanisms (disk instabilities, interactions via planets) might be responsible for the changes seen. The He I feature is most likely due to a wind whose orientation changes with respect to the observer on timescales of a day or less. To further constrain the origin of the gas and dust emission will require multiple spectroscopic and interferometric observations on both shorter and longer timescales that have been sampled so far.This work was supported by NASA ADP grants NNH06CC28C and NNX09AC73G, Hubble Space Telescope grants HST-GO-10764 and HST-GO-10864, Chilean National TAC grants CNTAC-010A-064

    A resolved, au-scale gas disk around the B[e] star HD 50138

    Get PDF
    articleHD 50138 is a B[e] star surrounded by a large amount of circumstellar gas and dust. Its spectrum shows characteristics which may indicate either a pre- or a post-main-sequence system. Mapping the kinematics of the gas in the inner few au of the system contributes to a better understanding of its physical nature. We present the first high spatial and spectral resolution interferometric observations of the Brγ line of HD 50138, obtained with VLTI/AMBER. The line emission originates in a region more compact (up to 3 au) than the continuum-emitting region. Blue- and red-shifted emission originates from the two different hemispheres of an elongated structure perpendicular to the polarization angle. The velocity of the emitting medium decreases radially. An overall offset along the NW direction between the line- and continuum-emitting regions is observed. We compare the data with a geometric model of a thin Keplerian disk and a spherical halo on top of a Gaussian continuum. Most of the data are well reproduced by this model, except for the variability, the global offset and the visibility at the systemic velocity. The evolutionary state of the system is discussed; most diagnostics are ambiguous and may point either to a post-main-sequence or a pre-main-sequence nature.National Science FoundationGeorgia State UniversityW.M. Keck FoundationDavid and Lucile Packard FoundationFizeau ProgramCNRS-PICS progra

    Quaternion Solution for the Rock'n'roller: Box Orbits, Loop Orbits and Recession

    Full text link
    We consider two types of trajectories found in a wide range of mechanical systems, viz. box orbits and loop orbits. We elucidate the dynamics of these orbits in the simple context of a perturbed harmonic oscillator in two dimensions. We then examine the small-amplitude motion of a rigid body, the rock'n'roller, a sphere with eccentric distribution of mass. The equations of motion are expressed in quaternionic form and a complete analytical solution is obtained. Both types of orbit, boxes and loops, are found, the particular form depending on the initial conditions. We interpret the motion in terms of epi-elliptic orbits. The phenomenon of recession, or reversal of precession, is associated with box orbits. The small-amplitude solutions for the symmetric case, or Routh sphere, are expressed explicitly in terms of epicycles; there is no recession in this case

    An empirical approach towards the efficient and optimal production of influenza-neutralizing ovine polyclonal antibodies demonstrates that the novel adjuvant CoVaccine HT(TM) is functionally superior to Freund's adjuvant

    Get PDF
    Passive immunotherapies utilising polyclonal antibodies could have a valuable role in preventing and treating infectious diseases such as influenza, particularly in pandemic situations but also in immunocompromised populations such as the elderly, the chronically immunosuppressed, pregnant women, infants and those with chronic diseases. The aim of this study was to optimise current methods used to generate ovine polyclonal antibodies. Polyclonal antibodies to baculovirus-expressed recombinant influenza haemagglutinin from A/Puerto Rico/8/1934 H1N1 (PR8) were elicited in sheep using various immunisation regimens designed to investigate the priming immunisation route, adjuvant formulation, sheep age, and antigen dose, and to empirically ascertain which combination maximised antibody output. The novel adjuvant CoVaccine HT™ was compared to Freund’s adjuvant which is currently the adjuvant of choice for commercial production of ovine polyclonal Fab therapies. CoVaccine HT™ induced significantly higher titres of functional ovine anti-haemagglutinin IgG than Freund’s adjuvant but with fewer side effects, including reduced site reactions. Polyclonal hyperimmune sheep sera effectively neutralised influenza virus in vitro and, when given before or after influenza virus challenge, prevented the death of infected mice. Neither the age of the sheep nor the route of antigen administration appeared to influence antibody titre. Moreover, reducing the administrated dose of haemagglutinin antigen minimally affected antibody titre. Together, these results suggest a cost effective way of producing high and sustained yields of functional ovine polyclonal antibodies specifically for the prevention and treatment of globally significant diseases.Natalie E. Stevens, Cara K. Fraser, Mohammed Alsharifi, Michael P. Brown, Kerrilyn R. Diener, John D. Haybal

    Leucine supplementation improves adiponectin and total cholesterol concentrations despite the lack of changes in adiposity or glucose homeostasis in rats previously exposed to a high-fat diet

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Studies suggest that leucine supplementation (LS) has a therapeutic potential to prevent obesity and to promote glucose homeostasis. Furthermore, regular physical exercise is a widely accepted strategy for body weight maintenance and also for the prevention of obesity. The aim of this study was to determine the effect of chronic LS alone or combined with endurance training (ET) as potential approaches for reversing the insulin resistance and obesity induced by a high-fat diet (HFD) in rats.</p> <p>Methods</p> <p>Forty-seven rats were randomly divided into two groups. Animals were fed a control diet-low fat (<it>n = </it>10) or HFD (<it>n = </it>37). After 15 weeks on HFD, all rats received the control diet-low fat and were randomly divided according to treatment: reference (REF), LS, ET, and LS+ET (<it>n = </it>7-8 rats per group). After 6 weeks of treatment, the animals were sacrificed and body composition, fat cell volume, and serum concentrations of total cholesterol, HDL-cholesterol, triacylglycerol, glucose, adiponectin, leptin and tumor necrosis factor-alpha (TNF-α) were analyzed.</p> <p>Results</p> <p>At the end of the sixth week of treatment, there was no significant difference in body weight between the REF, LS, ET and LS+ET groups. However, ET increased lean body mass in rats (<it>P </it>= 0.019). In addition, ET was more effective than LS in reducing adiposity (<it>P </it>= 0.019), serum insulin (<it>P </it>= 0.022) and TNF-α (<it>P </it>= 0.044). Conversely, LS increased serum adiponectin (<it>P </it>= 0.021) levels and reduced serum total cholesterol concentration (<it>P </it>= 0.042).</p> <p>Conclusions</p> <p>The results showed that LS had no beneficial effects on insulin sensitivity or adiposity in previously obese rats. On the other hand, LS was effective in increasing adiponectin levels and in reducing total cholesterol concentration.</p

    Do Patient Expectations Represent a More Important Clinical Difference? A Study of Surgical Outcomes in the Cervical Spine

    Get PDF
    Objective This study aims to compare the impact of achieving an MCID or meeting preoperative expectations on patient satisfaction following cervical spine procedures. Methods A surgical database was retrospectively reviewed for cervical spine surgery patients from 2016 to 2020. Inclusion criteria were primary or revision, single- or multilevel cervical disc arthroplasty or anterior cervical discectomy and fusions (ACDF). Visual analogue scale (VAS) neck and arm pain was assessed preoperatively and postoperatively (6-week, 12-weeks, 6-months, 1-year). Preoperative patient expectation and postoperative satisfaction were recorded. MCID achievement was determined using previously established values. Expectations met and MCID achievement were compared as possible predictors of satisfaction. Results One hundred and six cervical spine patients were included. Both meeting expectations and achieving MCID were significant predictors of satisfaction for arm pain at 6-weeks and 12-weeks (all p≤0.007). Achieving MCID significantly predicted satisfaction for neck pain at all timepoints (all p≤0.007) and meeting expectations predicted satisfaction for neck pain at 6-weeks, 12-weeks, and 1-year (all p≤0.003). Comparison of coefficients revealed no significant difference in effect size between meeting expectations and achievement of MCID as predictors of patient satisfaction (all p>0.050). Conclusion MCID achievement and meeting expectations were significant predictors of satisfaction for neck pain and short-term arm pain. Both measures may be similarly useful for interpretation of patient outcomes and the optimal choice of metric may depend on practice-specific factors

    Lateral Lumbar Interbody Fusion in the Outpatient Setting with Multimodal Analgesic Protocol: Clinical Case Series

    Get PDF
    Objective Minimally invasive techniques and multimodal analgesia protocols have made spine surgery in the outpatient setting increasingly feasible. A number of spinal procedures have been documented in the outpatient setting, though the feasibility of lateral lumbar interbody fusion (LLIF) on an ambulatory basis has not been thoroughly assessed. To present a clinical case series of patients undergoing LLIF in the outpatient setting. Methods A prospectively maintained surgical database was retrospectively reviewed to identify patients undergoing outpatient spine procedures with an enhanced multimodal analgesia protocol from October 2016 to February 2021. Patient demographics, medical and spinal diagnoses, procedural characteristics, operative duration, estimated blood loss (EBL), postoperative length of stay (LOS), postoperative pain scores, postoperative narcotic consumption, and incidence of any intra- or postoperative complications were collected. The state’s prescription monitoring program was queried to assess rates of filling narcotic prescriptions >6 weeks following surgery. Results A total of 24 LLIF patients were included. Mean postoperative pain score was 5.8, and mean postoperative narcotic consumption was 26.8 oral morphine equivalents. All patients were discharged on the same day of surgery. No postoperative complications were observed. After the 6-week postoperative timepoint, 16.7% of patients filled a prescription for tramadol, 8.3% for hydrocodone, 4.2% for hydromorphone, 4.2% for cyclobenzaprine, and 4.2% for alprazolam. Conclusion This clinical case series demonstrates that LLIF can be both safe and feasible in the outpatient setting, with minimal narcotic medication dependence in the postoperative period
    corecore