30 research outputs found

    Laseranwendung in der Augenheilkunde

    Get PDF
    Die Augenheilkunde stellt eine der medizinischen Fachdisziplinen dar, die Laserstrahlung schon sehr früh einsetzten und heute bei verschiedenen Erkrankungen anwenden. Zur Diagnostik und Therapie der Glaukome, bei Netzhauterkrankungen, aber auch zur Behandlung von Fehlsichtigkeiten werden verschiedene Lasertypen erfolgreich eingesetzt.Ophthalmology represents a medical field where laser technology was established very early and where lasers are nowadays frequently used. In the diagnosis and treatment of glaucoma, for treatment of retinal disorders as well as for refractive surgery different types of lasers are used

    Expression of the transcription factor Hes3 in the mouse and human ocular surface, and in pterygium

    Get PDF
    Purpose: In this work we examined the presence of the neural stem cell biomarker Hairy and Enhancer of Split 3 (Hes3) in the anterior eye segment and in the aberrant growth condition of the conjunctiva pterygium. Further, we studied the response of Hes3 to irradiation. Materials and methods: Adult mouse and human corneoscleral junction and conjunctiva, as well as human pterygium were prepared for immunohistochemical detection of Hes3 and other markers. Total body irradiation was used to study the changes in the pattern of Hes3 expression. Results: The adult rodent and human eye as well as pterygium, contain a population of cells expressing Hes3. In the human eye, Hes3-expressing (Hes3+) cells are found predominantly in the subconjunctival space spanning over the limbus where they physically associate with blood vessels. The cytoarchitecture of Hes3 + cells is similar to those previously observed in the adult central nervous system. Furthermore, irradiation reduces the number of Hes3 + cells in the subconjunctival space. In contrast, irradiation strongly promotes the nuclear localization of Hes3 in the ciliary body epithelium. Conclusions: Our results suggest that a recently identified signal transduction pathway that regulates neural stem cells and glioblastoma cancer stem cells also operates in the ocular surface, ciliary body, and in pterygium

    Comparison of Normal- and High-Tension Glaucoma: Nerve Fiber Layer and Optic Nerve Head Damage

    Get PDF
    Purpose: The aim of this study was to investigate differences in the nerve fiber layer and glaucoma-induced structural optic nerve head (ONH) damage in patients with normal- (NTG) and high-tension (HTG) glaucoma. Methods: In this retrospective pair-matched comparative study, 22 NTG and 22 HTG eyes were matched according to the same glaucomatous damage based on rim volume, rim area and disk size, as measured by Heidelberg retinal tomography (HRT III). Visual fields (VF) were assessed by Humphrey perimetry, and nerve fiber layer thickness was determined both by scanning laser polarimetry (GDxVCC) and spectral-domain optical coherence tomography (SD-OCT). Comparisons of all measured parameters were made between NTG and HTG groups. Results: Based on HRT results, both NTG and HTG eyes displayed comparable structural damage to the ONH (NTG/HTG, mean: disk area, 2.30/2.31 mm 2 , p = 0.942; rim area, 1.02/0.86 mm 2 , p = 0.082; rim volume, 0.19/0.17 mm 3 , p = 0.398). NTG eyes had significantly less VF damage than HTG eyes (NTG/HTG, mean deviation: –4.23/–12.12 dB, p = 0.002; pattern standard deviation: 5.39/8.23 dB, p = 0.022). The inferior nerve fiber layer of NTG patients was significantly thicker than that of HTG patients (NTG/HTG, mean: GDx inferior: 53.5/46.3 μm, p = 0.046). SD-OCT revealed a significantly thicker nerve fiber in NTG compared with HTG patients in all quadrants (NTG/HTG, total mean: 72.72/58.45 μm, p = 0.002). Conclusion: At comparable glaucomatous stages, nerve fiber loss was more advanced in HTG patients compared with NTG patients

    Measurement of the retinal venous pressure with a new instrument in healthy subjects

    No full text
    Background!#!The retinal venous pressure (RVP) is a determining factor for the blood supply of the retina as well as the optic nerve head and until recently has been measured by contact lens dynamometry (CLD). A new method has been developed, potentially offering better acceptance. The applicability and the results of both methods were compared.!##!Methods!#!The type of this study is cross sectional. The subjects were 36 healthy volunteers, age 26 ± 5 years (mean ± s). Tonometry: rebound tonometer (RT) (iCare). The measurements were performed during an increase in airway pressure of 20 mmHg (Valsalva manoeuvre). Principle of RVP measurement: the central retinal vein (CRV) is observed during an increase of intraocular pressure (IOP) and at the start of pulsation, which corresponds with the RVP. Two different instruments for the IOP enhancement where used: contact lens dynamometry and the new instrument, IOPstim.!##!Principle!#!a deflated balloon of 8 mm diameter-placed on the sclera laterally of the cornea-is filled with air. As soon as a venous pulsation occurs, filling is stopped and the IOP is measured, equalling the RVP. Examination procedure: randomization of the sequence: CLD or IOPstim, IOP, mydriasis, IOP three single measurements (SM) of the IOP with RT or of the pressure increase with CLD at an airway pressure of 20 mmHg, 5 min break, IOP, and three SM using the second method at equal pressure (20 mmHg).!##!Results!#!Spontaneous pulsation of the CRV was present in all 36 subjects. Pressures are given in mmHg. IOP in mydriasis 15.6 ± 3.3 (m ± s). Median RVP (MRVP)) of the three SM: CLD/IOPstim, 37.7 ± 5.2/24.7 ± 4.8 (t test: p < 0.001). Range of SM: 3.2 ± 1.8/2.9 ± 1.3 (t test: p = 0.36). Intraclass correlation coefficient (ICC) of SM: 0.88/0.83. ANOVA in SM: p = 0.48/0.08. MRVP CLD minus MRVP IOPstim: 13.0 ± 5.6. Ratio MRVP CLD/MRVP IOPstim: 1.56 ± 3.1. Cooperation and agreeability were slightly better with the IOPstim.!##!Conclusion!#!This first study with the IOPstim in humans was deliberately performed in healthy volunteers using Valsalva conditions. As demonstrated by ICC and ANOVA, reproducible SM can be obtained by both methods and the range of the SM does not differ greatly. The higher MRVP in CLD could be explained by the different directions of the force vectors

    Estimating pulsatile ocular blood volume from intraocular pressure, ocular pulse amplitude, and axial length

    No full text
    The purpose of this study was to develop a method of estimating pulsatile ocular blood volume (POBV) from measurements taken during an ophthalmic exam, including axial length and using a tonometer capable of measuring intraocular pressure (IOP) and ocular pulse amplitude (OPA). Unpublished OPA data from a previous invasive study was used in the derivation, along with central corneal thickness (CCT) and axial length (AL), as well as IOP from the PASCAL dynamic contour tonometer (DCT) and intracameral (ICM) measurements of IOP for 60 cataract patients. Intracameral mean pressure was set to 15, 20, and 35 mmHg (randomized sequence) in the supine position, using a fluid-filled manometer. IOP and OPA measurements were acquired at each manometric setpoint (DCT and ICM simultaneously). In the current study, ocular rigidity (OR) was estimated using a published significant relationship of OR to the natural log of AL in which OR was invasively measured through fluid injection. Friedenwald’s original pressure volume relationship was then used to derive the estimated POBV, delivered to the choroid with each heartbeat as a function of OR, systolic IOP (IOPsys), diastolic IOP (IOPdia), and OPA, according to the derived equation POBV = log (IOPsys/IOPdia) / OR. Linear regression analyses were performed comparing OPA to OR and calculated POBV at each of the three manometric setpoints. POBV was also compared to OPA/IOPdia with all data points combined. Significance threshold was p < 0.05. OR estimated from AL showed a significant positive relationship to OPA for both DCT (p < 0.011) and ICM (p < 0.006) at all three manometric pressure setpoints, with a greater slope for lower IOP. Calculated POBV also showed a significant positive relationship to OPA (p < 0.001) at all three setpoints with greater slope at lower IOP, and a significant negative relationship with IOPdia. In the combined analysis, POBV showed a significant positive relationship to OPA/ IOPdia (p < 0.001) in both ICM and DCT measurements with R2 = 0.9685, and R2 = 0.9589, respectively. POBV provides a straight-forward, clinically applicable method to estimate ocular blood supply noninvasively. Higher IOP in combination with lower OPA results in the lowest values of POBV. The simplified ratio, OPA/ IOPdia, may also provide a useful clinical tool for evaluating changes in ocular blood supply in diseases with a vascular component, such as diabetic retinopathy and normal tension glaucoma. Future studies are warranted

    Estimating pulsatile ocular blood volume from intraocular pressure, ocular pulse amplitude, and axial length.

    No full text
    The purpose of this study was to develop a method of estimating pulsatile ocular blood volume (POBV) from measurements taken during an ophthalmic exam, including axial length and using a tonometer capable of measuring intraocular pressure (IOP) and ocular pulse amplitude (OPA). Unpublished OPA data from a previous invasive study was used in the derivation, along with central corneal thickness (CCT) and axial length (AL), as well as IOP from the PASCAL dynamic contour tonometer (DCT) and intracameral (ICM) measurements of IOP for 60 cataract patients. Intracameral mean pressure was set to 15, 20, and 35 mmHg (randomized sequence) in the supine position, using a fluid-filled manometer. IOP and OPA measurements were acquired at each manometric setpoint (DCT and ICM simultaneously). In the current study, ocular rigidity (OR) was estimated using a published significant relationship of OR to the natural log of AL in which OR was invasively measured through fluid injection. Friedenwald's original pressure volume relationship was then used to derive the estimated POBV, delivered to the choroid with each heartbeat as a function of OR, systolic IOP (IOPsys), diastolic IOP (IOPdia), and OPA, according to the derived equation POBV = log (IOPsys/IOPdia) / OR. Linear regression analyses were performed comparing OPA to OR and calculated POBV at each of the three manometric setpoints. POBV was also compared to OPA/IOPdia with all data points combined. Significance threshold was p < 0.05. OR estimated from AL showed a significant positive relationship to OPA for both DCT (p < 0.011) and ICM (p < 0.006) at all three manometric pressure setpoints, with a greater slope for lower IOP. Calculated POBV also showed a significant positive relationship to OPA (p < 0.001) at all three setpoints with greater slope at lower IOP, and a significant negative relationship with IOPdia. In the combined analysis, POBV showed a significant positive relationship to OPA/ IOPdia (p < 0.001) in both ICM and DCT measurements with R2 = 0.9685, and R2 = 0.9589, respectively. POBV provides a straight-forward, clinically applicable method to estimate ocular blood supply noninvasively. Higher IOP in combination with lower OPA results in the lowest values of POBV. The simplified ratio, OPA/ IOPdia, may also provide a useful clinical tool for evaluating changes in ocular blood supply in diseases with a vascular component, such as diabetic retinopathy and normal tension glaucoma. Future studies are warranted

    Efficacy of selective laser trabeculoplasty on lowering intraocular pressure fluctuations and nocturnal peak intraocular pressure in treated primary open-angle glaucoma patients

    No full text
    Purpose To investigate the efficacy of adjunctive selective laser trabeculoplasty (SLT) in reducing 24-h intraocular pressure (IOP) fluctuations and nocturnal IOP peaks. Methods In this prospective interventional case series, 157 medically treated eyes of 157 patients with primary open-angle glaucoma (POAG) who were assigned SLT to further reduce IOP were consecutively included. Each patient had a complete glaucoma work-up and 24-h IOP monitoring (6 measurements, including one in the supine position) taken before and on average 6 months after SLT. The main outcome measures were the reduction of 24-h IOP fluctuations and nocturnal peak IOP. Secondary outcome measures were success rates, factors influencing the reduction of high 24-h IOP fluctuations and nocturnal peak IOP, complications, and severe adverse events. Results Medicated mean 24-h IOP (mmHg) was statistically significantly reduced from 15.1 ± 2.6 to 13.8 ± 2.4 (P < 0.001) and IOP fluctuations from 6.5 ± 2.7 to 5.4 ± 2.6 (P < 0.001) 6 months after SLT. Ninety-four eyes (59.9%) initially had high IOP fluctuations (more than 5 mmHg). These were reduced from 8.1 ± 2.3 to 5.6 ± 2.7 at 6 months (P < 0.001). Fifty-two eyes (55.3%) had fluctuations below 5 mmHg post-SLT which was defined as success. Fifty-one patients (32.5%) had nocturnal IOP peaks. In these cases, nocturnal IOP was reduced by 19.2% from 20.1 ± 3.4 to 16.2 ± 3.3 mmHg at 6 months (P = 0.001). Conclusions The current study demonstrates that adjunctive SLT not only reduces mean 24-h IOP in treated POAG patients, but also has an additional benefit in reducing IOP fluctuations and nocturnal peak IOP
    corecore