19 research outputs found

    Impact of the COVID-19 pandemic on admission rates for, and management of, acute coronary syndromes in England

    Get PDF
    Background Several countries affected by the COVID-19 pandemic have reported a substantial drop in the number of patients attending the emergency department with acute coronary syndromes and a reduced number of cardiac procedures. We aimed to understand the scale, nature, and duration of changes to admissions for different types of acute coronary syndrome in England and to evaluate whether in-hospital management of patients has been affected as a result of the COVID-19 pandemic. Methods We analysed data on hospital admissions in England for types of acute coronary syndrome from Jan 1, 2019, to May 24, 2020, that were recorded in the Secondary Uses Service Admitted Patient Care database. Admissions were classified as ST-elevation myocardial infarction (STEMI), non-STEMI (NSTEMI), myocardial infarction of unknown type, or other acute coronary syndromes (including unstable angina). We identified revascularisation procedures undertaken during these admissions (ie, coronary angiography without percutaneous coronary intervention [PCI], PCI, and coronary artery bypass graft surgery). We calculated the numbers of weekly admissions and procedures undertaken; percentage reductions in weekly admissions and across subgroups were also calculated, with 95% CIs. Findings Hospital admissions for acute coronary syndrome declined from mid-February, 2020, falling from a 2019 baseline rate of 3017 admissions per week to 1813 per week by the end of March, 2020, a reduction of 40% (95% CI 37–43). This decline was partly reversed during April and May, 2020, such that by the last week of May, 2020, there were 2522 admissions, representing a 16% (95% CI 13–20) reduction from baseline. During the period of declining admissions, there were reductions in the numbers of admissions for all types of acute coronary syndrome, including both STEMI and NSTEMI, but relative and absolute reductions were larger for NSTEMI, with 1267 admissions per week in 2019 and 733 per week by the end of March, 2020, a percent reduction of 42% (95% CI 38–46). In parallel, reductions were recorded in the number of PCI procedures for patients with both STEMI (438 PCI procedures per week in 2019 vs 346 by the end of March, 2020; percent reduction 21%, 95% CI 12–29) and NSTEMI (383 PCI procedures per week in 2019 vs 240 by the end of March, 2020; percent reduction 37%, 29–45). The median length of stay among patients with acute coronary syndrome fell from 4 days (IQR 2–9) in 2019 to 3 days (1–5) by the end of March, 2020. Interpretation Compared with the weekly average in 2019, there was a substantial reduction in the weekly numbers of patients with acute coronary syndrome who were admitted to hospital in England by the end of March, 2020, which had been partly reversed by the end of May, 2020. The reduced number of admissions during this period is likely to have resulted in increases in out-of-hospital deaths and long-term complications of myocardial infarction and missed opportunities to offer secondary prevention treatment for patients with coronary heart disease. The full extent of the effect of COVID-19 on the management of patients with acute coronary syndrome will continue to be assessed by updating these analyses

    CODE-EHR best practice framework for the use of structured electronic healthcare records in clinical research

    Get PDF
    Big data is central to new developments in global clinical science aiming to improve the lives of patients. Technological advances have led to the routine use of structured electronic healthcare records with the potential to address key gaps in clinical evidence. The covid-19 pandemic has demonstrated the potential of big data and related analytics, but also important pitfalls. Verification, validation, and data privacy, as well as the social mandate to undertake research are key challenges. The European Society of Cardiology and the BigData@Heart consortium have brought together a range of international stakeholders, including patient representatives, clinicians, scientists, regulators, journal editors and industry. We propose the CODE-EHR Minimum Standards Framework as a means to improve the design of studies, enhance transparency and develop a roadmap towards more robust and effective utilisation of healthcare data for research purposes

    Reduction of low density lipoprotein- cholesterol and cardiovascular events with proprotein convertase subtilisin-kexin type 9 (PCSK9) inhibitors and statins: an analysis of FOURIER, SPIRE, and the Cholesterol Treatment Trialists Collaboration

    Get PDF
    Treatment with proprotein convertase subtilisin-kexin type 9 (PCSK9) inhibitors reduce low density lipoprotein cholesterol (LDL-C) by approximately 45–60%, whether used alone or in combination with a statin.1,2 Two large cardiovascular outcomes trials have now reported that lowering LDL-C with a PCSK9 inhibitor when added to treatment with a statin reduces the risk of major cardiovascular events.3,4 We sought to compare the efficacy of PCSK9 inhibitors and statins for reducing the risk of cardiovascular events by comparing the results of the FOURIER and SPIRE trials with the results of the Cholesterol Treatment Trialists (CTT) meta-analysis of statin trials.5,

    Relations between professional medical associations and the health-care industry, concerning scientific communication and continuing medical education: a Policy Statement from the European Society of Cardiology

    Get PDF
    Physicians have an ethical duty to keep up-to-date with current knowledge. Professional medical associations such as the European Society of Cardiology (ESC) support these obligations. In Europe, the costs of continuing medical education (CME) are insufficiently supported from governments and employers; however, medical associations have been criticized for accepting alternative financial support from industry. Medical education and training in research include learning how to assess the quality and reliability of any information. There is some risk of bias in any form of scientific communication including intellectual, professional, and financial and it is essential that in particular, the latter must be acknowledged by full disclosure. It is essential that there is strong collaboration between basic and clinical researchers from academic institutions on the one hand, with engineers and scientists from the research divisions of device and pharmaceutical companies on the other. This is vital so that new diagnostic methods and treatments are developed. Promotion of advances by industry may accelerate their implementation into clinical practice. Universities now frequently exhort their academic staff to protect their intellectual property or commercialize their research. Thus, it is not commercial activity or links per se that have become the target for criticism but the perceived influence of commercial enterprises on clinical decision-making or on messages conveyed by professional medical organizations. This document offers the perspective of the ESC on the current debate, and it recommends how to minimize bias in scientific communications and CME and how to ensure proper ethical standards and transparency in relations between the medical profession and industry

    Five-year clinical outcomes and intracoronary imaging findings of the COMFORTABLE AMI trial: randomized comparison of biodegradable polymer-based biolimus-eluting stents with bare-metal stents in patients with acute ST-segment elevation myocardial infarction

    Get PDF
    AIMS The long-term outcomes of biolimus-eluting stents (BESs) with biodegradable polymer as compared with bare-metal stent (BMS) in patients with ST-segment elevation myocardial infarction (STEMI) remain unknown. METHODS AND RESULTS We performed a 5-year clinical follow-up of 1157 patients (BES: N = 575 and BMS: N = 582) included in the randomized COMFORTABLE AMI trial. Serial intracoronary imaging of stented segments using both intravascular ultrasound (IVUS) and optical coherence tomography performed at baseline and 13 months follow-up were analysed in 103 patients. At 5 years, BES reduced the risk of major adverse cardiac events [MACE; hazard ratio (HR) 0.56, 95% confidence interval (CI): 0.39-0.79, P = 0.001], driven by lower risks for target vessel-related reinfarction (HR 0.44, 95% CI: 0.22-0.87, P = 0.02) and ischaemia-driven target lesion revascularization (HR 0.41, 95% CI: 0.25-0.66, P < 0.001). Definite stent thrombosis (ST) was recorded in 2.2% and 3.9% (HR 0.57, 95% CI: 0.28-1.16, P = 0.12) with no differences in rates of very late definite ST (1.3% vs. 1.6%, P = 0.77). Optical coherence tomography showed no difference in the frequency of malapposed stent struts at follow-up (BES 0.08% vs. BMS 0.02%, P = 0.10). Uncovered stent struts were rarely observed but more frequent in BES (2.1% vs. 0.15%, P < 0.001). In the IVUS analysis, there was no positive remodelling in either group (external elastic membrane area change BES: -0.63 mm2, 95% CI: -1.44 to 0.39 vs. BMS -1.11 mm2, 95% CI: -2.27 to 0.04, P = 0.07). CONCLUSION Compared with BMS, the implantation of biodegradable polymer-coated BES resulted in a lower 5-year rate of MACE in patients with STEMI undergoing primary percutaneous coronary intervention. At 13 months, vascular healing in treated culprit lesions was almost complete irrespective of stent type. CLINICAL TRIAL REGISTRATION http://www.clinicaltrials.gov. Unique identifier: NCT00962416
    corecore