    United Kingdom Early Detection Initiative (UK-EDI) : protocol for establishing a national multicentre cohort of individuals with new-onset diabetes for early detection of pancreatic cancer

    Get PDF
    INTRODUCTION: Pancreatic cancer is a leading cause of cancer deaths worldwide. Screening for this disease has potential to improve survival. It is not feasible, with current screening modalities, to screen the asymptomatic adult population. However, screening of individuals in high-risk groups is recommended. Our study aims to provide resources and data that will inform strategies to screen individuals with new-onset diabetes (NOD) for pancreatic cancer. METHODS AND ANALYSIS: The United Kingdom Early Detection Initiative (UK-EDI) for pancreatic cancer is a national, prospective, observational cohort study that aims to recruit 2500 individuals with NOD (<6 months postdiagnosis) aged 50 years and over, with follow-up every 6 months, over a 3-year period. For study eligibility, diagnosis of diabetes is considered to be clinical measurement of haemoglobin A1c ≥48 mmol/mol. Detailed clinical information and biospecimens will be collected at baseline and follow-up to support the development of molecular, epidemiological and demographic biomarkers for earlier detection of pancreatic cancer in the high-risk NOD group. Socioeconomic impacts and cost-effectiveness of earlier detection of pancreatic cancer in individuals with NOD will be evaluated. The UK-EDI NOD cohort will provide a bioresource for future early detection research to be conducted. ETHICS AND DISSEMINATION: The UK-EDI study has been reviewed and approved by the London-West London and GTAC Research Ethics Committee (Ref 20/LO/0058). Study results will be disseminated through presentations at national and international symposia and publication in peer-reviewed, Open Access journals

    Safety and efficacy of the ChAdOx1 nCoV-19 vaccine (AZD1222) against SARS-CoV-2: an interim analysis of four randomised controlled trials in Brazil, South Africa, and the UK.

    Get PDF
    BACKGROUND: A safe and efficacious vaccine against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), if deployed with high coverage, could contribute to the control of the COVID-19 pandemic. We evaluated the safety and efficacy of the ChAdOx1 nCoV-19 vaccine in a pooled interim analysis of four trials. METHODS: This analysis includes data from four ongoing blinded, randomised, controlled trials done across the UK, Brazil, and South Africa. Participants aged 18 years and older were randomly assigned (1:1) to ChAdOx1 nCoV-19 vaccine or control (meningococcal group A, C, W, and Y conjugate vaccine or saline). Participants in the ChAdOx1 nCoV-19 group received two doses containing 5 × 1010 viral particles (standard dose; SD/SD cohort); a subset in the UK trial received a half dose as their first dose (low dose) and a standard dose as their second dose (LD/SD cohort). The primary efficacy analysis included symptomatic COVID-19 in seronegative participants with a nucleic acid amplification test-positive swab more than 14 days after a second dose of vaccine. Participants were analysed according to treatment received, with data cutoff on Nov 4, 2020. Vaccine efficacy was calculated as 1 - relative risk derived from a robust Poisson regression model adjusted for age. Studies are registered at ISRCTN89951424 and ClinicalTrials.gov, NCT04324606, NCT04400838, and NCT04444674. FINDINGS: Between April 23 and Nov 4, 2020, 23 848 participants were enrolled and 11 636 participants (7548 in the UK, 4088 in Brazil) were included in the interim primary efficacy analysis. In participants who received two standard doses, vaccine efficacy was 62·1% (95% CI 41·0-75·7; 27 [0·6%] of 4440 in the ChAdOx1 nCoV-19 group vs71 [1·6%] of 4455 in the control group) and in participants who received a low dose followed by a standard dose, efficacy was 90·0% (67·4-97·0; three [0·2%] of 1367 vs 30 [2·2%] of 1374; pinteraction=0·010). Overall vaccine efficacy across both groups was 70·4% (95·8% CI 54·8-80·6; 30 [0·5%] of 5807 vs 101 [1·7%] of 5829). From 21 days after the first dose, there were ten cases hospitalised for COVID-19, all in the control arm; two were classified as severe COVID-19, including one death. There were 74 341 person-months of safety follow-up (median 3·4 months, IQR 1·3-4·8): 175 severe adverse events occurred in 168 participants, 84 events in the ChAdOx1 nCoV-19 group and 91 in the control group. Three events were classified as possibly related to a vaccine: one in the ChAdOx1 nCoV-19 group, one in the control group, and one in a participant who remains masked to group allocation. INTERPRETATION: ChAdOx1 nCoV-19 has an acceptable safety profile and has been found to be efficacious against symptomatic COVID-19 in this interim analysis of ongoing clinical trials. FUNDING: UK Research and Innovation, National Institutes for Health Research (NIHR), Coalition for Epidemic Preparedness Innovations, Bill & Melinda Gates Foundation, Lemann Foundation, Rede D'Or, Brava and Telles Foundation, NIHR Oxford Biomedical Research Centre, Thames Valley and South Midland's NIHR Clinical Research Network, and AstraZeneca

    Safety and efficacy of the ChAdOx1 nCoV-19 vaccine (AZD1222) against SARS-CoV-2: an interim analysis of four randomised controlled trials in Brazil, South Africa, and the UK

    Get PDF
    Background A safe and efficacious vaccine against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), if deployed with high coverage, could contribute to the control of the COVID-19 pandemic. We evaluated the safety and efficacy of the ChAdOx1 nCoV-19 vaccine in a pooled interim analysis of four trials. Methods This analysis includes data from four ongoing blinded, randomised, controlled trials done across the UK, Brazil, and South Africa. Participants aged 18 years and older were randomly assigned (1:1) to ChAdOx1 nCoV-19 vaccine or control (meningococcal group A, C, W, and Y conjugate vaccine or saline). Participants in the ChAdOx1 nCoV-19 group received two doses containing 5 × 1010 viral particles (standard dose; SD/SD cohort); a subset in the UK trial received a half dose as their first dose (low dose) and a standard dose as their second dose (LD/SD cohort). The primary efficacy analysis included symptomatic COVID-19 in seronegative participants with a nucleic acid amplification test-positive swab more than 14 days after a second dose of vaccine. Participants were analysed according to treatment received, with data cutoff on Nov 4, 2020. Vaccine efficacy was calculated as 1 - relative risk derived from a robust Poisson regression model adjusted for age. Studies are registered at ISRCTN89951424 and ClinicalTrials.gov, NCT04324606, NCT04400838, and NCT04444674. Findings Between April 23 and Nov 4, 2020, 23 848 participants were enrolled and 11 636 participants (7548 in the UK, 4088 in Brazil) were included in the interim primary efficacy analysis. In participants who received two standard doses, vaccine efficacy was 62·1% (95% CI 41·0–75·7; 27 [0·6%] of 4440 in the ChAdOx1 nCoV-19 group vs71 [1·6%] of 4455 in the control group) and in participants who received a low dose followed by a standard dose, efficacy was 90·0% (67·4–97·0; three [0·2%] of 1367 vs 30 [2·2%] of 1374; pinteraction=0·010). Overall vaccine efficacy across both groups was 70·4% (95·8% CI 54·8–80·6; 30 [0·5%] of 5807 vs 101 [1·7%] of 5829). From 21 days after the first dose, there were ten cases hospitalised for COVID-19, all in the control arm; two were classified as severe COVID-19, including one death. There were 74 341 person-months of safety follow-up (median 3·4 months, IQR 1·3–4·8): 175 severe adverse events occurred in 168 participants, 84 events in the ChAdOx1 nCoV-19 group and 91 in the control group. Three events were classified as possibly related to a vaccine: one in the ChAdOx1 nCoV-19 group, one in the control group, and one in a participant who remains masked to group allocation. Interpretation ChAdOx1 nCoV-19 has an acceptable safety profile and has been found to be efficacious against symptomatic COVID-19 in this interim analysis of ongoing clinical trials

    Application of Liquid Chromatography - Tandem Mass Spectrometry Techniques to Forensic, Environmental and Clinical Analyses.

    No full text
    Liquid chromatography - tandem mass spectrometry (LC-MS/MS) is a powerful technique offering superior selectivity, sensitivity and flexibility for a diverse range of applications. This document describes the application of LC-MS/MS to analytical problems in environmental, clinical and forensic fields. LC-UV and LC-MS/MS methods were implemented and compared for the analysis of nitroaromatics, nitramines and nitrate esters in soil. Analysis of soils collected at detonation sites showed the presence and concentration of contaminants to be a function of parameters such as: time since detonation, type of charge employed, nature of detonation and size of charge used. Multi-increment (MI) sampling strategies recommended by the Environmental Protection Agency (EPA) were found to be impractical for wilderness environments. A structured grid strategy (SGS) is described which would allow representative sampling in complex terrain and enable the distinction between areas of high and low contamination, to more appropriately evaluate remediation needs. A new method was developed for the analysis of trace levels of buprenorphine, fentanyl and their metabolites in mice from low (\u3c100 μL) plasma volumes. The method was fully validated, allowing an evaluation of current validation recommendations. The study highlighted the importance of using ion ratios as part of routine quantification, not just in method development. Another observation found that where suppression of internal standard signals resulted in reproducibility outside of standard limits (\u3e20% RSD), if the signal was stable and within the linear range, the ratio of the analyte and internal standard signals was consistent and proportional to the concentration of analyte. This could impact current acceptance criteria for internal standard peak area reproducibility. A new hydrophilic interaction liquid chromatography (HILIC)-MS/MS method for the determination of cocaine and fentanyl, capable of indicating the smoked route of administration is described. The method was found to be highly selective and sensitive especially for basic and highly polar acidic species. Challenges facing traditional reverse phase (RP) LC separation of the highly hydrophilic compounds ecgonine, anhydroecgonine methyl ester and anhydroecgonine are eliminated in hydrophobic interaction (HI) mode through the incorporation of multiple retention mechanisms. The method could be easily adapted to the separation of other acidic, basic or highly polar drug compounds where RP separation has previously not been possible

    Where the metabolome meets the microbiome for pancreatic cancer detection.

    No full text
    Risk prediction tools for pancreatic cancer are urgently sought to facilitate screening. Irajizad et al.1 describe the performance of a risk predication model based on circulating microbial- and non-microbial metabolites for assessment of 5-year pancreatic cancer risk

    Three images that show wartime photographs can have greater impact than the written word

    No full text
    “Images are worth a thousand words. These images may be worth a million.” US secretary of state Antony Blinken’s response to being shown graphic images of the victims of Hamas’s recent massacre raises an important question about whether photographs are more powerful than words in conveying the brutality of war.Please note: This article contains images that some may finding distressing, including of torture