4 research outputs found

    Prevalence of asymptomatic malaria infections in selected military camps in Tanzania

    Get PDF
    Background: Despite a decrease in malaria burden reported between 2000 and 2015, an increasing trend of malaria transmission has been recently reported in some endemic countries including Tanzania. Periodic monitoring to identify pocket areas for asymptomatic Plasmodium falciparum infection   is vital for malaria elimination efforts. The objective of this study was to determine prevalence of asymptomatic malaria infections among military recruits in selected camps in Tanzania. Methods: A cross-sectional study was conducted in 2015 at four military camps (Bulombora, Mgambo, Ruvu, and Rwamkoma) of National Service located in regions with varying malaria endemicity in Tanzania.  Finger prick blood samples collected from asymptomatic military recruits who had been at the camps for over two months were simultaneously tested using microscopy and malaria rapid diagnostic tests (mRDTs) to detect malaria parasite infections. Results: Malaria parasite prevalence among asymptomatic recruits was 20.3% and 19.4% by microscopy and mRDT respectively. There was moderate agreement (Kappa=0.724) between microscopy and mRDT test results. A significant difference (p<0.001) of malaria parasite prevalence among the four study camps was observed; ranging from 1.9% in Bulombora to 39.4% in Rwamkoma. The geometric mean parasite density was 11,053 asexual parasites/µl and most recruits (56.8%) had 200 to 1999 asexual parasites/µl. P. falciparum was the predominant (99.2%) malaria parasite species. Conclusion: Our study found high prevalence of asymptomatic malaria infections among military recruits in the selected camps, and this varied from one camp to another. The study has highlighted that public residence institutions such as military camps can be potential hotspots for malaria infection and therefore should not be skipped in routine national malaria surveillance system for monitoring trends of infection

    Preexposure prophylaxis for HIV infection among African women.

    Get PDF
    BACKGROUND: Preexposure prophylaxis with antiretroviral drugs has been effective in the prevention of human immunodeficiency virus (HIV) infection in some trials but not in others. METHODS: In this randomized, double-blind, placebo-controlled trial, we assigned 2120 HIV-negative women in Kenya, South Africa, and Tanzania to receive either a combination of tenofovir disoproxil fumarate and emtricitabine (TDF-FTC) or placebo once daily. The primary objective was to assess the effectiveness of TDF-FTC in preventing HIV acquisition and to evaluate safety. RESULTS: HIV infections occurred in 33 women in the TDF-FTC group (incidence rate, 4.7 per 100 person-years) and in 35 in the placebo group (incidence rate, 5.0 per 100 person-years), for an estimated hazard ratio in the TDF-FTC group of 0.94 (95% confidence interval, 0.59 to 1.52; P=0.81). The proportions of women with nausea, vomiting, or elevated alanine aminotransferase levels were significantly higher in the TDF-FTC group (P=0.04, P<0.001, and P=0.03, respectively). Rates of drug discontinuation because of hepatic or renal abnormalities were higher in the TDF-FTC group (4.7%) than in the placebo group (3.0%, P=0.051). Less than 40% of the HIV-uninfected women in the TDF-FTC group had evidence of recent pill use at visits that were matched to the HIV-infection window for women with seroconversion. The study was stopped early, on April 18, 2011, because of lack of efficacy. CONCLUSIONS: Prophylaxis with TDF-FTC did not significantly reduce the rate of HIV infection and was associated with increased rates of side effects, as compared with placebo. Despite substantial counseling efforts, drug adherence appeared to be low. (Supported by the U.S. Agency for International Development and others; FEM-PrEP ClinicalTrials.gov number, NCT00625404.)

    The use of Fionet technology for external quality control of malaria rapid diagnostic tests and monitoring health workers' performance in rural military health facilities in Tanzania.

    No full text
    IntroductionInternal and external quality control (QC) of rapid diagnostic tests (RDTs) is important to increase reliability of RDTs currently used to diagnose malaria. However, cross-checking of used RDTs as part of quality assurance can rarely be done by off-site personnel because there is no guarantee of retaining visible test lines after manufacturers' recommended reading time. Therefore, this study examined the potential of using Fionetâ„¢ technology for remote RDT quality monitoring at seven clinics, identifying reasons for making RDT processing and interpretation errors, and taking corrective actions for improvement of diagnosis and consequently improved management of febrile patients.MethodsThe study was conducted at seven military health facilities in Mainland Tanzania and utilized RDTs capable of detecting Plasmodium falciparum specific Histidine-rich protein 2 (Pf-HRP2) and the genus specific Plasmodium lactate dehydrogenase (pLDH) for other species of plasmodium (P. vivax, P. malariae or P. ovale; pan-pLDH). Patients' data and images of processed RDTs from seven clinics were uploaded on a Fionet web portal and reviewed regularly to monitor preparation procedures and visual interpretation of test results compared to automated analysis using the Deki reader of RDT. Problems detected were rapidly communicated to remote laboratory personnel at the clinic for corrective action and follow-up of patients who were falsely diagnosed as negative and missed treatment. Factors contributing to making errors in visual interpretation of RDT results were analyzed during visits to the health facilities.ResultsA total of 1,367 (1.6%) out of 83,294 RDT test images uploaded to the Fionet portal had discordant test results of which 822 (60.1%) and 545 (39.9%) were falsely reported as negative and positive, respectively. False negative and false positive test results were common for a single test line in 515 (62.7%) and 741 (54.2%) tests, respectively. Out of 1,367 RDT images assessed, 98 (7.2%) had quality problems related to preparation procedures of which 95(96.9%) errors were due to putting too much blood on the sample well or insufficient buffer in the respective wells. The reasons for discrepant results included, false reporting of none existent lines in 526 (38.5%) tests, missing a faint positive line in 493 (36.1%), missing a strong positive line in 248(18.1%) and errors caused by poorly processed RDTs in 96 (7.2%) tests. Among the false negative tests (n = 822), 669 (48.9%) patients were eligible for follow-up and only 339 (48.5%) were reached and 291 (85.8%) received appropriate anti-malaria therapy.ConclusionFionet technology enabled remote monitoring of RDT quality issues, identifying reasons contributing to laboratory personnel making errors and provided a rapid method to implement corrective actions at remote sites to improve malaria diagnosis and consequently improved health care management of febrile patients infected with malaria
    corecore