85 research outputs found

    Image Derived Input Functions: Effects of Motion on Tracer Kinetic Analyses

    Get PDF
    Purpose: To quantify the effects of motion affected image-derived input functions (IDIF) on the outcome of tracer kinetic analyses. Procedures: Two simulation studies, one based on high and the other on low cortical uptake, were performed. Different degrees of rotational and axial translational motion were added to the final frames of simulated dynamic positron emission tomography scans. Extracted IDIFs from motion affected simulated scans were compared to original IDIFs and to outcome of tracer kinetic analysis (volume of distribution, V T). Results: Differences in IDIF values of up to 239 % were found for the last frames. Patient motion of more than 6 ° or 5 mm resulted in at least 10 % higher or lower VT values for the high cortical tracer. Conclusion: The degrees of motion studied are commonly observed in clinical studies and hamper the extraction of accurate IDIFs. Therefore, it is essential to ensure that patient motion is minimal and corrected for

    Partial volume correction of brain PET studies using iterative deconvolution in combination with HYPR denoising

    Get PDF
    Background: Accurate quantification of PET studies depends on the spatial resolution of the PET data. The commonly limited PET resolution results in partial volume effects (PVE). Iterative deconvolution methods (IDM) have been proposed as a means to correct for PVE. IDM improves spatial resolution of PET studies without the need for structural information (e.g. MR scans). On the other hand, deconvolution also increases noise, which results in lower signal-to-noise ratios (SNR). The aim of this study was to implement IDM in combination with HighlY constrained back-PRojection (HYPR) denoising to mitigate poor SNR properties of conventional IDM.Methods: An anthropomorphic Hoffman brain phantom was filled with an [F-18]FDG solution of similar to 25 kBq mL(-1) and scanned for 30 min on a Philips Ingenuity TF PET/CT scanner (Philips, Cleveland, USA) using a dynamic brain protocol with various frame durations ranging from 10 to 300 s. Van Cittert IDM was used for PVC of the scans. In addition, HYPR was used to improve SNR of the dynamic PET images, applying it both before and/or after IDM. The Hoffman phantom dataset was used to optimise IDM parameters (number of iterations, type of algorithm, with/without HYPR) and the order of HYPR implementation based on the best average agreement of measured and actual activity concentrations in the regions. Next, dynamic [C-11]flumazenil (five healthy subjects) and [C-11]PIB (four healthy subjects and four patients with Alzheimer's disease) scans were used to assess the impact of IDM with and without HYPR on plasma input-derived distribution volumes (V-T) across various regions of the brain.Results: In the case of [C-11]flumazenil scans, Hypr-IDM-Hypr showed an increase of 5 to 20% in the regional V-T whereas a 0 to 10% increase or decrease was seen in the case of [C-11]PIB depending on the volume of interest or type of subject (healthy or patient). References for these comparisons were the V(T)s from the PVE-uncorrected scans.Conclusions: IDM improved quantitative accuracy of measured activity concentrations. Moreover, the use of IDM in combination with HYPR (Hypr-IDM-Hypr) was able to correct for PVE without increasing noise.</p

    Quantitative imaging of 124I and 86Y with PET

    Get PDF
    The quantitative accuracy and image quality of positron emission tomography (PET) measurements with 124I and 86Y is affected by the prompt emission of gamma radiation and positrons in their decays, as well as the higher energy of the emitted positrons compared to those emitted by 18F. PET scanners cannot distinguish between true coincidences, involving two 511-keV annihilation photons, and coincidences involving one annihilation photon and a prompt gamma, if the energy of this prompt gamma is within the energy window of the scanner. The current review deals with a number of aspects of the challenge this poses for quantitative PET imaging. First, the effect of prompt gamma coincidences on quantitative accuracy of PET images is discussed and a number of suggested corrections are described. Then, the effect of prompt gamma coincidences and the increased singles count rates due to gamma radiation on the count rate performance of PET is addressed, as well as possible improvements based on modification of the scanner’s energy windows. Finally, the effect of positron energy on spatial resolution and recovery is assessed. The methods presented in this overview aim to overcome the challenges associated with the decay characteristics of 124I and 86Y. Careful application of the presented correction methods can allow for quantitatively accurate images with improved image contrast

    Diabetic cardiomyopathy in Zucker diabetic fatty rats: the forgotten right ventricle

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In patients with myocardial infarction or heart failure, right ventricular (RV) dysfunction is associated with death, shock and arrhythmias. In patients with type 2 diabetes mellitus, structural and functional alterations of the left ventricle (LV) are highly prevalent, however, little is known about the impact of diabetes on RV characteristics. The purpose of the present study was to investigate whether LV changes are paralleled by RV alterations in a rat model of diabetes.</p> <p>Methods</p> <p>Zucker diabetic fatty (ZDF) and control (ZL) rats underwent echocardiography and positron emission tomography (PET) scanning using [<sup>18</sup>F]-2-fluoro-2-deoxy-D-glucose under hyperinsulinaemic euglycaemic clamp conditions. Glucose, insulin, triglycerides and fatty acids were assessed from trunk blood. Another group of rats received an insulin or saline injection to study RV insulin signaling.</p> <p>Results</p> <p>ZDF rats developed hyperglycaemia, hyperinsulinaemia and dyslipidaemia (all p < 0.05). Echocardiography revealed depressed LV fractional shortening and tricuspid annular plane systolic excursion (TAPSE) in ZDF vs. ZL rats (both p < 0.05). A decrease in LV and RV insulin-mediated glucose utilisation was found in ZDF vs. ZL rats (both p < 0.05). LV associated with RV with respect to systolic function (r = 0.86, p < 0.05) and glucose utilisation (r = 0.74, p < 0.05). TAPSE associated with RV MRglu (r = 0.92, p < 0.05) and <it>M</it>-value (r = 0.91, p < 0.0001) and RV MRglu associated with <it>M</it>-value (r = 0.77, p < 0.05). Finally, reduced RV insulin-stimulated phosphorylation of Akt was found in ZDF vs. ZL (p < 0.05).</p> <p>Conclusions</p> <p>LV changes were paralleled by RV alterations in insulin-stimulated glucose utilisation and RV systolic function in a rat model of diabetes, which may be attributed to ventricular interdependence as well as to the uniform effect of diabetes. Since diabetic patients are prone to develop diabetic cardiomyopathy and myocardial ischaemia, it might be suggested that RV dysfunction plays a central role in cardiac abnormalities in this population.</p

    Altered myocardial substrate metabolism is associated with myocardial dysfunction in early diabetic cardiomyopathy in rats: studies using positron emission tomography

    Get PDF
    0.05). CONCLUSION: Using PET and echocardiography, we found increases in myocardial FA oxidation with a concomitant decrease of insulin-mediated myocardial glucose utilisation in early DCM. In addition, the latter was associated with impaired myocardial function. These in vivo data expand previous in vitro findings showing that early alterations in myocardial substrate metabolism contribute to myocardial dysfunctio
    corecore