460 research outputs found

    One-dimensional vertical dust strings in a glass box

    Full text link
    The oscillation spectrum of a one-dimensional vertical dust string formed inside a glass box on top of the lower electrode in a GEC reference cell was studied. A mechanism for creating a single vertical dust string is described. It is shown that the oscillation amplitudes, resonance frequencies, damping coefficients, and oscillation phases of the dust particles separate into two distinct groups. One group exhibits low damping coefficients, increasing amplitudes and decreasing resonance frequencies for dust particles closer to the lower electrode. The other group shows high damping coefficients but anomalous resonance frequencies and amplitudes. At low oscillation frequencies, the two groups are also separated by a {\pi}-phase difference. One possible cause for the difference in behavior between the two groups is discussed

    Origin of the spin reorientation transitions in (Fe1x_{1-x}Cox_{x})2_{2}B alloys

    Get PDF
    Low-temperature measurements of the magnetocrystalline anisotropy energy KK in (Fe1x_{1-x}Cox_{x})2_{2}B alloys are reported, and the origin of this anisotropy is elucidated using a first-principles electronic structure analysis. The calculated concentration dependence K(x)K(x) with a maximum near x=0.3x=0.3 and a minimum near x=0.8x=0.8 is in excellent agreement with experiment. This dependence is traced down to spin-orbital selection rules and the filling of electronic bands with increasing electronic concentration. At the optimal Co concentration, KK depends strongly on the tetragonality and doubles under a modest 3% increase of the c/ac/a ratio, suggesting that the magnetocrystalline anisotropy can be further enhanced using epitaxial or chemical strain.Comment: 4 pages + supplementary material, 6 figures. Accepted in Applied Physics Letter

    Models and experimental results from the wide aperture Nb-Ti magnets for the LHC upgrade

    Full text link
    MQXC is a Nb-Ti quadrupole designed to meet the accelerator quality requirements needed for the phase-1 LHC upgrade, now superseded by the high luminosity upgrade foreseen in 2021. The 2-m-long model magnet was tested at room temperature and 1.9 K. The technology developed for this magnet is relevant for other magnets currently under development for the high-luminosity upgrade, namely D1 (at KEK) and the large aperture twin quadrupole Q4 (at CEA). In this paper we present MQXC test results, some of the specialized heat extraction features, spot heaters, temperature sensor mounting and voltage tap development for the special open cable insulation. We look at some problem solving with noisy signals, give an overview of electrical testing, look at how we calculate the coil resistance during at quench and show that the heaters are not working We describe the quench signals and its timing, the development of the quench heaters and give an explanation of an Excel quench calculation and its comparison including the good agreement with the MQXC test results. We propose an improvement to the magnet circuit design to reduce voltage to ground values by factor 2. The program is then used to predict quench Hot-Spot and Voltages values for the D1 dipole and the Q4 quadrupole.Comment: 8 pages, Contribution to WAMSDO 2013: Workshop on Accelerator Magnet, Superconductor, Design and Optimization; 15 - 16 Jan 2013, CERN, Geneva, Switzerlan

    Strategies Utilized to Transfer Weight During Knee Flexion and Extension With Rotation for Individuals With a Total Knee Replacement

    Get PDF
    Functional activities in daily life can require squatting and shifting body weight during transverse plane rotations. Stability of the knee can be challenging for people with a total knee replacement (TKR) due to reduced proprioception, nonconforming articular geometry, muscle strength, and soft tissue weakness. The objective of this study was to identify strategies utilized by individuals with TKR in double-stance transferring load during rotation and flexion. Twenty-three subjects were recruited for this study: 11 TKR subjects (age: 65 6 6 years; BMI 27.4 6 4.1) and 12 healthy subjects (age: 63 6 7; BMI 24.6 6 3.8). Each subject completed a novel crossover button push task where rotation, flexion, and extension of the knee were utilized. Each subject performed two crossover reaching tasks where the subject used the opposite hand to cross over their body and press a button next to either their shoulder (high) or knee (low), then switched hands and rotated to press the opposite button, either low or high. The two tasks related to the order they pressed the buttons while crossing over, either low-to-high (L2H) or high-to-low (H2L). Force platforms measured ground reaction forces under each foot, which were then converted to lead force ratios (LFRs) based on the total force. Knee flexion angles were also measured. No statistical differences were found in the LFRs during the H2L and L2H tasks for the different groups, although differences in the variation of the loading within subjects were noted. A significant difference was found between healthy and unaffected knee angles and a strong trend between healthy and affected subject's knee angles in both H2L and L2H tasks. Large variations in the LFR at mid-task in the TKR subjects suggested possible difficulties in maintaining positional stability during these tasks. The TKR subjects maintained more of an extended knee, which is a consistent quadriceps avoidance strategy seen by other researchers in different tasks. These outcomes suggest that individuals with a TKR utilize strategies, such as keeping an extended knee, to achieve rotary tasks during knee flexion and extension. Repeated compensatory movements could result in forces that may cause difficulty over time in the hip joints or low back. Early identification of these strategies could improve TKR success and the return to activities of daily living that involve flexion and rotation

    Multiphase equation of state for carbon addressing high pressures and temperatures

    Get PDF
    We present a 5-phase equation of state for elemental carbon which addresses a wide range of density and temperature conditions: 3g/cc 100 000K (both for ρ between 3 and 12 g/cc, with select higher-ρ DFT calculations as well). The liquid free energy model includes an atom-in-jellium approach to account for the effects of ionization due to temperature and pressure in the plasma state, and an ion-thermal model which includes the approach to the ideal gas limit. The precise manner in which the ideal gas limit is reached is greatly constrained by both the highest-temperature DFT data and the path integral data, forcing us to discard an ion-thermal model we had used previously in favor of a new one. Predictions are made for the principal Hugoniot and the room-temperature isotherm, and comparisons are made to recent experimental results.United States. Dept. of Energy (Contract DE-AC52-07NA27344

    Patellar mechanics during simulated kneeling in the natural and implanted knee

    Get PDF
    AbstractKneeling is required during daily living for many patients after total knee replacement (TKR), yet many patients have reported that they cannot kneel due to pain, or avoid kneeling due to discomfort, which critically impacts quality of life and perceived success of the TKR procedure. The objective of this study was to evaluate the effect of component design on patellofemoral (PF) mechanics during a kneeling activity. A computational model to predict natural and implanted PF kinematics and bone strains after kneeling was developed and kinematics were validated with experimental cadaveric studies. PF joint kinematics and patellar bone strains were compared for implants with dome, medialized dome, and anatomic components. Due to the less conforming nature of the designs, change in sagittal plane tilt as a result of kneeling at 90° knee flexion was approximately twice as large for the medialized-dome and dome implants as the natural case or anatomic implant, which may result in additional stretching of the quadriceps. All implanted cases resulted in substantial increases in bone strains compared with the natural knee, but increased strains in different regions. The anatomic patella demonstrated increased strains inferiorly, while the dome and medialized dome showed increases centrally. An understanding of the effect of implant design on patellar mechanics during kneeling may ultimately provide guidance to component designs that reduces the likelihood of knee pain and patellar fracture during kneeling

    Experimental and computational characterization of a modified GEC cell for dusty plasma experiments

    Full text link
    A self-consistent fluid model developed for simulations of micro- gravity dusty plasma experiments has for the first time been used to model asymmetric dusty plasma experiments in a modified GEC reference cell with gravity. The numerical results are directly compared with experimental data and the experimentally determined dependence of global discharge parameters on the applied driving potential and neutral gas pressure is found to be well matched by the model. The local profiles important for dust particle transport are studied and compared with experimentally determined profiles. The radial forces in the midplane are presented for the different discharge settings. The differences between the results obtained in the modified GEC cell and the results first reported for the original GEC reference cell are pointed out
    corecore