63 research outputs found
Sub-femto-g free fall for space-based gravitational wave observatories: LISA pathfinder results
We report the first results of the LISA Pathfinder in-flight experiment. The results demonstrate that two free-falling reference test masses, such as those needed for a space-based gravitational wave observatory like LISA, can be put in free fall with a relative acceleration noise with a square root of the power spectral density of 5.2 ± 0.1 fm sâ2/âHz or (0.54 ± 0.01) Ă 10â15 g/âHz, with g the standard gravity, for frequencies between 0.7 and 20 mHz. This value is lower than the LISA Pathfinder requirement by more than a factor 5 and within a factor 1.25 of the requirement for the LISA mission, and is compatible with Brownian noise from viscous damping due to the residual gas surrounding the test masses. Above 60 mHz the acceleration noise is dominated by interferometer displacement readout noise at a level of (34.8 ± 0.3) fm/âHz, about 2 orders of magnitude better than requirements. At f †0.5 mHz we observe a low-frequency tail that stays below 12 fm sâ2/âHz down to 0.1 mHz. This performance would allow for a space-based gravitational wave
observatory with a sensitivity close to what was originally foreseen for LISA
The Unitary Gas and its Symmetry Properties
The physics of atomic quantum gases is currently taking advantage of a
powerful tool, the possibility to fully adjust the interaction strength between
atoms using a magnetically controlled Feshbach resonance. For fermions with two
internal states, formally two opposite spin states, this allows to prepare long
lived strongly interacting three-dimensional gases and to study the BEC-BCS
crossover. Of particular interest along the BEC-BCS crossover is the so-called
unitary gas, where the atomic interaction potential between the opposite spin
states has virtually an infinite scattering length and a zero range. This
unitary gas is the main subject of the present chapter: It has fascinating
symmetry properties, from a simple scaling invariance, to a more subtle
dynamical symmetry in an isotropic harmonic trap, which is linked to a
separability of the N-body problem in hyperspherical coordinates. Other
analytical results, valid over the whole BEC-BCS crossover, are presented,
establishing a connection between three recently measured quantities, the tail
of the momentum distribution, the short range part of the pair distribution
function and the mean number of closed channel molecules.Comment: 63 pages, 8 figures. Contribution to the Springer Lecture Notes in
Physics "BEC-BCS Crossover and the Unitary Fermi gas" edited by Wilhelm
Zwerger. Revised version correcting a few typo
Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures
Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo
- âŠ