134 research outputs found

    Necrosis óseas asépticas avasculares

    Get PDF
    Se presentan 30 casos de necrosis osea aséptica avascular. Se hace el análisis de los hallazgos clínicos, de los métodos de laboratorio empleados para el diagnóstico, de los factores que pueden desempeñar algún papel en su génesis y de los diferentes tipos de tratamiento empleados.30 cases of avascular aseptic bone necrosis are presented. The clinical findings, the laboratory methods used for diagnosis, the factors that may play a role in the pathogenesis and the different schedules of treatment used are analyzed

    Assembly and Test of a Support Structure for 3.6 m Long Nb3Sn Racetrack Coils”,

    Get PDF
    Abstract-The LHC Accelerator Research Program (LARP) is currently developing 4 m long Nb 3 Sn quadrupole magnets for a possible upgrade of the LHC Interaction Regions (IR). In order to provide a reliable test bed for the fabrication and test of long Nb 3 Sn coils, LARP has started the development of the long racetrack magnet LRS01. The magnet is composed of two 3.6 m long racetrack coils contained in a support structure based on an aluminum shell pre-tensioned with water-pressurized bladders and interference keys. For the phase-one test of the assembly procedure and loading operation, the structure was pre-stressed at room temperature and cooled down to 77 K with instrumented, solid aluminum "dummy coils". Mechanical behavior and stress homogeneity were monitored with strain gauges mounted on the shell and the dummy coils. The dummy coils were replaced with reacted and impregnated Nb 3 Sn coils in a second assembly procedure, followed by cool-down to 4.5 K and powered magnet test. This paper report on the assembly and loading procedures of the support structure as well as the comparison between strain gauge data and 3D model predictions

    Study of Isomeric States in <sup>198,200,202,206</sup>Pb and <sup>206</sup>Hg Populated in Fragmentation Reactions

    Get PDF
    Isomeric states in isotopes in the vicinity of doubly-magic 208Pb were populated following reactions of a relativistic 208Pb primary beam impinging on a 9Be fragmentation target. Secondary beams of 198;200;202;206Pb and 206Hg were isotopically separated and implanted in a passive stopper positioned in the focal plane of the GSI Fragment Separator. Delayed Îł rays were detected with the Advanced GAmma Tracking Array (AGATA). Decay schemes were re-evaluated and interpreted with shell-model calculations. The momentum-dependent population of isomeric states in the two-nucleon hole nuclei 206Pb/206Hg was found to differ from the population of multi neutron-hole isomeric states in 198;200;202Pb

    Summary of HQ01e magnetic measurements

    Get PDF
    The magnetic measurements of HQ01e, a 1 m long LHC Accelerator Research Program (LARP) high-gradient quadrupole model, were performed at 4.4 K and above 40 K at the magnet test facility of LBNL in July 2011. The 120 mm aperture cos2θ Nb{sub 3}Sn magnet was designed with accelerator magnet features including alignment and field quality. Conductor-limited gradient was 195 T/m at 4.4 K. During the measurement, a ramp rate of 10 A/s was used and measurements at the nominal current of 14.2 kA (82% of short-sample limit with a gradient of 160 T/m) were performed using the 250 mm long printed-circuit board rotating probe developed by FNAL. At 14.2 kA, 2.7 units of b{sub 6} and 0.7 units of b{sub 10} were measured. Large persistent current contribution and strong dynamic effects were observed. We analyzed the allowed and non-allowed harmonics obtained during the measurements above 40 K and at the nominal current. Significant change of the skew sextupole occurred between 50 K and 95 K. The allowed multipole and the low-order non-allowed multipoles at the straight section were explained through the rigid displacement of coil blocks with an amplitude less than 100 μm. We also attempted to correlate the coil asymmetry (a{sub 3} and b{sub 3}) with the measured coil pole azimuthal strain. The dynamic multipole measured at the magnetic straight section varied linearly with the ramp rate of magnet current ranging from 10 A/s to 60 A/s. It was attributed to the inter-strand coupling currents with low crossover resistance. The crossover resistance of the cables at the inner layer of the magnet was estimated to range between 0.2 μΩ to 0.7 μΩ

    Effect of the COVID-19 pandemic on surgery for indeterminate thyroid nodules (THYCOVID): a retrospective, international, multicentre, cross-sectional study

    Get PDF
    Background Since its outbreak in early 2020, the COVID-19 pandemic has diverted resources from non-urgent and elective procedures, leading to diagnosis and treatment delays, with an increased number of neoplasms at advanced stages worldwide. The aims of this study were to quantify the reduction in surgical activity for indeterminate thyroid nodules during the COVID-19 pandemic; and to evaluate whether delays in surgery led to an increased occurrence of aggressive tumours.Methods In this retrospective, international, cross-sectional study, centres were invited to participate in June 22, 2022; each centre joining the study was asked to provide data from medical records on all surgical thyroidectomies consecutively performed from Jan 1, 2019, to Dec 31, 2021. Patients with indeterminate thyroid nodules were divided into three groups according to when they underwent surgery: from Jan 1, 2019, to Feb 29, 2020 (global prepandemic phase), from March 1, 2020, to May 31, 2021 (pandemic escalation phase), and from June 1 to Dec 31, 2021 (pandemic decrease phase). The main outcomes were, for each phase, the number of surgeries for indeterminate thyroid nodules, and in patients with a postoperative diagnosis of thyroid cancers, the occurrence of tumours larger than 10 mm, extrathyroidal extension, lymph node metastases, vascular invasion, distant metastases, and tumours at high risk of structural disease recurrence. Univariate analysis was used to compare the probability of aggressive thyroid features between the first and third study phases. The study was registered on ClinicalTrials.gov, NCT05178186.Findings Data from 157 centres (n=49 countries) on 87 467 patients who underwent surgery for benign and malignant thyroid disease were collected, of whom 22 974 patients (18 052 [78 center dot 6%] female patients and 4922 [21 center dot 4%] male patients) received surgery for indeterminate thyroid nodules. We observed a significant reduction in surgery for indeterminate thyroid nodules during the pandemic escalation phase (median monthly surgeries per centre, 1 center dot 4 [IQR 0 center dot 6-3 center dot 4]) compared with the prepandemic phase (2 center dot 0 [0 center dot 9-3 center dot 7]; p&lt;0 center dot 0001) and pandemic decrease phase (2 center dot 3 [1 center dot 0-5 center dot 0]; p&lt;0 center dot 0001). Compared with the prepandemic phase, in the pandemic decrease phase we observed an increased occurrence of thyroid tumours larger than 10 mm (2554 [69 center dot 0%] of 3704 vs 1515 [71 center dot 5%] of 2119; OR 1 center dot 1 [95% CI 1 center dot 0-1 center dot 3]; p=0 center dot 042), lymph node metastases (343 [9 center dot 3%] vs 264 [12 center dot 5%]; OR 1 center dot 4 [1 center dot 2-1 center dot 7]; p=0 center dot 0001), and tumours at high risk of structural disease recurrence (203 [5 center dot 7%] of 3584 vs 155 [7 center dot 7%] of 2006; OR 1 center dot 4 [1 center dot 1-1 center dot 7]; p=0 center dot 0039).Interpretation Our study suggests that the reduction in surgical activity for indeterminate thyroid nodules during the COVID-19 pandemic period could have led to an increased occurrence of aggressive thyroid tumours. However, other compelling hypotheses, including increased selection of patients with aggressive malignancies during this period, should be considered. We suggest that surgery for indeterminate thyroid nodules should no longer be postponed even in future instances of pandemic escalation.Funding None.Copyright (c) 2023 Published by Elsevier Ltd. All rights reserved
    • …
    corecore