7,987 research outputs found

    Spontaneous immunogenicity of ribosomal P0 protein in patients with benign and malignant breast lesions and delay of mammary tumor growth in P0-vaccinated mice

    Get PDF
    A common carboxyl-terminal epitope (C-22 P0) of the ribosomal P proteins (P0, P1 and P2) was shown to elicit autoantibodies in systemic lupus erythematosus (SLE) and in head and neck cancer patients. In this report we provide evidence for the in vivo immunogenicity of the P0 protein in breast cancer patients. Using recombinant P proteins, we demonstrated that sera from breast carcinoma patients (8/75) displayed significant reactivity to P0 protein when compared with healthy donor sera (0/45). Four out of the eight sera showed simultaneous reactivity to all P proteins. Breast benign tumor (3/17) and mammary hyperplasia (3/17) patient sera also showed significant reactivity to P proteins, thus suggesting that the occurrence of P protein autoantibodies might reveal mammary cell cycle dysregulation. Patient sera reacting with all P proteins recognized C-22 P0. Anti-P0 autoantibodies did not correlate with prognostic parameters of breast carcinomas. High level expression of C-22 P0 was found in mammary carcinomas compared with normal adjacent epithelium and benign lesions. To determine the antitumor activity of P0 as an immunogen, BALB-neuT transgenic mice displaying age-related breast cancer progression were vaccinated using xenogeneic P0 at the stage of mammary atypical hyperplasia. P0 vaccination significantly delayed the onset of mouse mammary tumors that overexpressed C-22 P0. Sera from P0 vaccinated mice recognized C-22 P0. Evidence for immunity to the P0 protein, its overexpression in carcinomas and its peculiar surface localization on cancer cells, along with its antitumor activity as an immunogen might be relevant for the use of P0 protein in monitoring cancer progression and in planning immunotherapeutic strategies

    Comparison of established and emerging biodosimetry assays

    Get PDF
    Rapid biodosimetry tools are required to assist with triage in the case of a large-scale radiation incident. Here, we aimed to determine the dose-assessment accuracy of the well-established dicentric chromosome assay (DCA) and cytokinesis-block micronucleus assay (CBMN) in comparison to the emerging γ-H2AX foci and gene expression assays for triage mode biodosimetry and radiation injury assessment. Coded blood samples exposed to 10 X-ray doses (240 kVp, 1 Gy/min) of up to 6.4 Gy were sent to participants for dose estimation. Report times were documented for each laboratory and assay. The mean absolute difference (MAD) of estimated doses relative to the true doses was calculated. We also merged doses into binary dose categories of clinical relevance and examined accuracy, sensitivity and specificity of the assays. Dose estimates were reported by the first laboratories within 0.3-0.4 days of receipt of samples for the γ-H2AX and gene expression assays compared to 2.4 and 4 days for the DCA and CBMN assays, respectively. Irrespective of the assay we found a 2.5-4-fold variation of interlaboratory accuracy per assay and lowest MAD values for the DCA assay (0.16 Gy) followed by CBMN (0.34 Gy), gene expression (0.34 Gy) and γ-H2AX (0.45 Gy) foci assay. Binary categories of dose estimates could be discriminated with equal efficiency for all assays, but at doses ≥1.5 Gy a 10% decrease in efficiency was observed for the foci assay, which was still comparable to the CBMN assay. In conclusion, the DCA has been confirmed as the gold standard biodosimetry method, but in situations where speed and throughput are more important than ultimate accuracy, the emerging rapid molecular assays have the potential to become useful triage tools

    Gene-specific inhibition of breast carcinoma in BALB-neuT mice by active immunization with rat Neu or human ErbB receptors

    Get PDF
    Employing the transgenic BALB-neuT mouse tumor model, we explored the in vivo biologic relevance of immunocompetent epitopes shared among the four ErbB receptors. The outcome of neu-mediated tumorigenesis was compared following vaccination with isogeneic normal rat ErbB2/Neu (LTR-Neu) or xenogeneic human ErbB receptors (LTR-EGFR, LTR-ErbB2, LTR-ErbB3 and LTR-ErbB4), each recombinantly expressed in an NIH3T3 murine cell background. Vaccination using rat LTR-Neu at the stage of atypical hyperplasia potently inhibited neu-mediated mammary tumorigenesis. Moreover, all human ErbB receptors specifically interfered with tumor development in BALB-neuT mice. Relative increase in tumor-free survival and reduction in tumor incidence corresponded to structural similarity shared with the etiologic neu oncogene, as rat orthologue LTR-Neu proved most effective followed by the human homologue LTR-ErbB2 and the other three human ErbB receptors. Vaccination resulted in high titer specific serum antibodies, whose tumor-inhibitory effect correlated with cross-reactivity to purified rat Neu extracellular domain in vitro. Furthermore, a T cell response specific for peptide epitopes of rat Neu was elicited in spleen cells of mice immunized with LTR-Neu and was remotely detectable for discrete peptides upon vaccination with LTR-ErbB2 and LTR-EGFR. The most pronounced tumor inhibition by LTR-Neu vaccination was associated with leukocyte infiltrate and tumor necrosis in vivo, while immune sera specifically induced cytotoxicity and apoptosis of BALB-neuT tumor cells in vitro. Our findings indicated that targeted inhibition of neu oncogene-mediated mammary carcinogenesis is conditional upon the immunization schedule and discrete immunogenic epitopes shared to a variable extent by different ErbB receptors

    Surfactant lung delivery with LISA and InSurE in adult rabbits with respiratory distress

    Get PDF
    Background: In preterm infants, InSurE (Intubation\u2013Surfactant\u2013Extubation) and LISA (less invasive surfactant administration) techniques allow for exogenous surfactant administration while reducing lung injury associated with mechanical ventilation. We compared the acute pulmonary response and lung deposition of surfactant by LISA and InSurE in surfactant-depleted adult rabbits. Methods: Twenty-six spontaneously breathing surfactant-depleted adult rabbits (6\u20137 weeks old) with moderate RDS and managed with nasal continuous positive airway pressure were randomized to 3 groups: (1) 200 mg/kg of surfactant by InSurE; (2) 200 mg/kg of surfactant by LISA; (3) no surfactant treatment (Control). Gas exchange and lung mechanics were monitored for 180 min. After that, surfactant lung deposition and distribution were evaluated monitoring disaturated-phosphatidylcholine (DSPC) and surfactant protein C (SP-C), respectively. Results: No signs of recovery were found in the untreated animals. After InSurE, oxygenation improved more rapidly compared to LISA. However, at 180\u2019 LISA and InSurE showed comparable outcomes in terms of gas exchange, ventilation parameters, and lung mechanics. Neither DSPC in the alveolar pool nor SP-C signal distributions in a frontal lung section were significantly different between InSurE and LISA groups. Conclusions: In an acute setting, LISA demonstrated efficacy and surfactant lung delivery similar to that of InSurE in surfactant-depleted adult rabbits. Impact: Although LISA technique is gaining popularity, there are still several questions to address. This is the first study comparing LISA and InSurE in terms of gas exchange, ventilation parameters, and lung mechanics as well as surfactant deposition and distribution.In our animal study, three hours post-treatment, LISA method seems to be as effective as InSurE and showed similar surfactant lung delivery.Our findings provide some clarifications on a fair comparison between LISA and InSurE techniques, particularly in terms of surfactant delivery. They should reassure some of the concerns raised by the clinical community on LISA adoption in neonatal units

    Surfactant lung delivery with LISA and InSurE in adult rabbits with respiratory distress

    Get PDF
    Background In preterm infants, InSurE (Intubation–Surfactant–Extubation) and LISA (less invasive surfactant administration) techniques allow for exogenous surfactant administration while reducing lung injury associated with mechanical ventilation. We compared the acute pulmonary response and lung deposition of surfactant by LISA and InSurE in surfactant-depleted adult rabbits. Methods Twenty-six spontaneously breathing surfactant-depleted adult rabbits (6–7 weeks old) with moderate RDS and managed with nasal continuous positive airway pressure were randomized to 3 groups: (1) 200 mg/kg of surfactant by InSurE; (2) 200 mg/kg of surfactant by LISA; (3) no surfactant treatment (Control). Gas exchange and lung mechanics were monitored for 180 min. After that, surfactant lung deposition and distribution were evaluated monitoring disaturated-phosphatidylcholine (DSPC) and surfactant protein C (SP-C), respectively. Results No signs of recovery were found in the untreated animals. After InSurE, oxygenation improved more rapidly compared to LISA. However, at 180’ LISA and InSurE showed comparable outcomes in terms of gas exchange, ventilation parameters, and lung mechanics. Neither DSPC in the alveolar pool nor SP-C signal distributions in a frontal lung section were significantly different between InSurE and LISA groups. Conclusions In an acute setting, LISA demonstrated efficacy and surfactant lung delivery similar to that of InSurE in surfactant-depleted adult rabbits. Impact Although LISA technique is gaining popularity, there are still several questions to address. This is the first study comparing LISA and InSurE in terms of gas exchange, ventilation parameters, and lung mechanics as well as surfactant deposition and distribution. In our animal study, three hours post-treatment, LISA method seems to be as effective as InSurE and showed similar surfactant lung delivery. Our findings provide some clarifications on a fair comparison between LISA and InSurE techniques, particularly in terms of surfactant delivery. They should reassure some of the concerns raised by the clinical community on LISA adoption in neonatal units

    A facility to Search for Hidden Particles (SHiP) at the CERN SPS

    Get PDF
    A new general purpose fixed target facility is proposed at the CERN SPS accelerator which is aimed at exploring the domain of hidden particles and make measurements with tau neutrinos. Hidden particles are predicted by a large number of models beyond the Standard Model. The high intensity of the SPS 400~GeV beam allows probing a wide variety of models containing light long-lived exotic particles with masses below O{\cal O}(10)~GeV/c2^2, including very weakly interacting low-energy SUSY states. The experimental programme of the proposed facility is capable of being extended in the future, e.g. to include direct searches for Dark Matter and Lepton Flavour Violation.Comment: Technical Proposa

    High rate, fast timing Glass RPC for the high {\eta} CMS muon detectors

    Full text link
    The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of magnitude up to 6.1034cm−2s−16.10^{34} cm^{-2} s^{-1} . The region of the forward muon spectrometer (∣η∣>1.6|{\eta}| > 1.6) is not equipped with RPC stations. The increase of the expected particles rate up to 2kHz/cm22 kHz/cm^{2} (including a safety factor 3) motivates the installation of RPC chambers to guarantee redundancy with the CSC chambers already present. The actual RPC technology of CMS cannot sustain the expected background level. The new technology that will be chosen should have a high rate capability and provides a good spatial and timing resolution. A new generation of Glass-RPC (GRPC) using low-resistivity (LR) glass is proposed to equip at least the two most far away of the four high η{\eta} muon stations of CMS. First the design of small size prototypes and studies of their performance in high-rate particles flux is presented. Then the proposed designs for large size chambers and their fast-timing electronic readout are examined and preliminary results are provided.Comment: 14 pages, 11 figures, Conference proceeding for the 2016 Resistive Plate Chambers and Related Detector

    Constraining Supersymmetry

    Get PDF
    We review constraints on the minimal supersymmetric extension of the Standard Model (MSSM) coming from direct searches at accelerators such as LEP, indirect measurements such as b -> s gamma decay and the anomalous magnetic moment of the muon. The recently corrected sign of pole light-by-light scattering contributions to the latter is taken into account. We combine these constraints with those due to the cosmological density of stable supersymmetric relic particles. The possible indications on the supersymmetric mass scale provided by fine-tuning arguments are reviewed critically. We discuss briefly the prospects for future accelerator searches for supersymmetry.Comment: 21 LaTeX pages, 9 eps figures, Invited Contribution to the New Journal of Physics Focus Issue on Supersymmetr

    Blood-based biomarkers for Alzheimer disease: mapping the road to the clinic.

    Get PDF
    Biomarker discovery and development for clinical research, diagnostics and therapy monitoring in clinical trials have advanced rapidly in key areas of medicine - most notably, oncology and cardiovascular diseases - allowing rapid early detection and supporting the evolution of biomarker-guided, precision-medicine-based targeted therapies. In Alzheimer disease (AD), breakthroughs in biomarker identification and validation include cerebrospinal fluid and PET markers of amyloid-ÎČ and tau proteins, which are highly accurate in detecting the presence of AD-associated pathophysiological and neuropathological changes. However, the high cost, insufficient accessibility and/or invasiveness of these assays limit their use as viable first-line tools for detecting patterns of pathophysiology. Therefore, a multistage, tiered approach is needed, prioritizing development of an initial screen to exclude from these tests the high numbers of people with cognitive deficits who do not demonstrate evidence of underlying AD pathophysiology. This Review summarizes the efforts of an international working group that aimed to survey the current landscape of blood-based AD biomarkers and outlines operational steps for an effective academic-industry co-development pathway from identification and assay development to validation for clinical use.I recieved an honorarium from Roche Diagnostics for my participation in the advisory panel meeting leading to this pape
    • 

    corecore