118 research outputs found

    Heart rate detection properties of dry-electrode ECG compared to conventional 3-lead gel-electrode ECG in newborns

    Get PDF
    Objective To compare the accuracy of heart rate detection properties of a novel, wireless, dry-electrode electrocardiogram (ECG) device, NeoBeat®, to that of a conventional 3-lead gel-electrode ECG monitor (PropaqM®) in newborns. Results The study population had a mean gestational age of 39 weeks and 2 days (1.5 weeks) and birth weight 3528 g (668 g). There were 950 heart rate notations from each device, but heart rate was absent from the reference monitor in 14 of these data points, leaving 936 data pairs to compare. The mean (SD) difference when comparing NeoBeat to the reference monitor was -0.25 (9.91) beats per minute (bpm) (p = 0.44). There was a deviation of more than 10 bpm in 7.4% of the data pairs, which primarily (78%) was attributed to ECG signal disturbance, and secondly (22%) due to algorithm differences between the devices. Excluding these outliers, the correlation was equally consistent (r2 = 0.96) in the full range of heart rate captured measurements with a mean difference of − 0.16 (3.09) bpm. The mean difference was less than 1 bpm regardless of whether outliers were included or not.publishedVersio

    Delivery Room ST Segment Analysis to Predict Short Term Outcomes in Near-Term and Term Newborns

    Get PDF
    Background: ST-segment changes to the fetal electrocardiogram (ECG) may indicate fetal acidosis. No large-scale characterization of ECG morphology immediately after birth has been performed, but ECG is used for heart rate (HR) assessment. We aimed to investigate ECG morphology immediately after birth in asphyxiated infants, using one-lead dry-electrode ECG developed for HR measurement. Methods: Observational study in Tanzania, between 2013-2018. Near-term and term infants that received bag-mask ventilation (BMV), and healthy controls, were monitored with one-lead dry-electrode ECG with a non-diagnostic bandwidth. ECGs were classified as normal, with ST-elevations or other ST-segment abnormalities including a biphasic ST-segment. We analyzed ECG morphology in relation to perinatal variables or short-term outcomes. Results: A total of 494 resuscitated and 25 healthy infants were included. ST-elevations were commonly seen both in healthy infants (7/25; 28%) and resuscitated (320/494; 65%) infants. The apparent ST-elevations were not associated with perinatal variables or short-term outcomes. Among the 32 (6.4%) resuscitated infants with other ST-segment abnormalities , duration of BMV was longer, 1-min Apgar score lower and normal outcomes less frequent than in the resuscitated infants with normal ECG or ST-elevations. Conclusions: ST-segment elevation was commonly seen and not associated with negative outcomes when using one-lead dry-electrode ECG. Other ST-segment abnormalities were associated with prolonged BMV and worse outcome. ECG with appropriate bandwidth and automated analysis may potentially in the future aid in the identification of severely asphyxiated infants

    Delivery Room ST Segment Analysis to Predict Short Term Outcomes in Near-Term and Term Newborns

    Get PDF
    Background: ST-segment changes to the fetal electrocardiogram (ECG) may indicate fetal acidosis. No large-scale characterization of ECG morphology immediately after birth has been performed, but ECG is used for heart rate (HR) assessment. We aimed to investigate ECG morphology immediately after birth in asphyxiated infants, using one-lead dry-electrode ECG developed for HR measurement. Methods: Observational study in Tanzania, between 2013–2018. Near-term and term infants that received bag-mask ventilation (BMV), and healthy controls, were monitored with one-lead dry-electrode ECG with a non-diagnostic bandwidth. ECGs were classified as normal, with ST-elevations or other ST-segment abnormalities including a biphasic ST-segment. We analyzed ECG morphology in relation to perinatal variables or short-term outcomes. Results: A total of 494 resuscitated and 25 healthy infants were included. ST-elevations were commonly seen both in healthy infants (7/25; 28%) and resuscitated (320/494; 65%) infants. The apparent ST-elevations were not associated with perinatal variables or short-term outcomes. Among the 32 (6.4%) resuscitated infants with “other ST-segment abnormalities”, duration of BMV was longer, 1-min Apgar score lower and normal outcomes less frequent than in the resuscitated infants with normal ECG or ST-elevations. Conclusions: ST-segment elevation was commonly seen and not associated with negative outcomes when using one-lead dry-electrode ECG. Other ST-segment abnormalities were associated with prolonged BMV and worse outcome. ECG with appropriate bandwidth and automated analysis may potentially in the future aid in the identification of severely asphyxiated infants

    Fetal to Neonatal Heart Rate Transition during Normal Vaginal Deliveries: A Prospective Observational Study

    Get PDF
    Documentation of fetal to neonatal heart rate (HR) transition is limited. The aim of the current study was to describe HR changes from one hour before to one hour after normal vaginal deliveries. We conducted a prospective observational cohort study in Tanzania from 1 October 2020 to 30 August 2021, including normal vaginal deliveries with normal neonatal outcomes. HR was continuously recorded from one hour before to one hour after delivery, using the Moyo fetal HR meter, NeoBeat newborn HR meter, and the Liveborn Application for data storage. The median, 25th, and 75th HR percentiles were constructed. Overall, 305 deliveries were included. Median (interquartile range; IQR) gestational age was 39 (38–40) weeks and birthweight was 3200 (3000–3500) grams. HR decreased slightly during the last 60 min before delivery from 136 (123,145) to 132 (112,143) beats/minute. After delivery, HR increased within one minute to 168 (143,183) beats/min, before decreasing to around 136 (127,149) beats/min at 60 min after delivery. The drop in HR in the last hour of delivery reflects strong contractions and pushing. The rapid increase in initial neonatal HR reflects an effort to establish spontaneous breathing.publishedVersio

    Delivery Room ST Segment Analysis to Predict Short Term Outcomes in Near-Term and Term Newborns

    Get PDF
    Background: ST-segment changes to the fetal electrocardiogram (ECG) may indicate fetal acidosis. No large-scale characterization of ECG morphology immediately after birth has been performed, but ECG is used for heart rate (HR) assessment. We aimed to investigate ECG morphology immediately after birth in asphyxiated infants, using one-lead dry-electrode ECG developed for HR measurement. Methods: Observational study in Tanzania, between 2013–2018. Near-term and term infants that received bag-mask ventilation (BMV), and healthy controls, were monitored with one-lead dry-electrode ECG with a non-diagnostic bandwidth. ECGs were classified as normal, with ST-elevations or other ST-segment abnormalities including a biphasic ST-segment. We analyzed ECG morphology in relation to perinatal variables or short-term outcomes. Results: A total of 494 resuscitated and 25 healthy infants were included. ST-elevations were commonly seen both in healthy infants (7/25; 28%) and resuscitated (320/494; 65%) infants. The apparent ST-elevations were not associated with perinatal variables or short-term outcomes. Among the 32 (6.4%) resuscitated infants with “other ST-segment abnormalities”, duration of BMV was longer, 1-min Apgar score lower and normal outcomes less frequent than in the resuscitated infants with normal ECG or ST-elevations. Conclusions: ST-segment elevation was commonly seen and not associated with negative outcomes when using one-lead dry-electrode ECG. Other ST-segment abnormalities were associated with prolonged BMV and worse outcome. ECG with appropriate bandwidth and automated analysis may potentially in the future aid in the identification of severely asphyxiated infants.publishedVersio

    Comparing Methods of Calculating Expected Annual Damage in Urban Pluvial Flood Risk Assessments

    Get PDF
    Estimating the expected annual damage (EAD) due to flooding in an urban area is of great interest for urban water managers and other stakeholders. It is a strong indicator for a given area showing how vulnerable it is to flood risk and how much can be gained by implementing e.g., climate change adaptation measures. This study identifies and compares three different methods for estimating the EAD based on unit costs of flooding of urban assets. One of these methods was used in previous studies and calculates the EAD based on a few extreme events by assuming a log-linear relationship between cost of an event and the corresponding return period. This method is compared to methods that are either more complicated or require more calculations. The choice of method by which the EAD is calculated appears to be of minor importance. At all three case study areas it seems more important that there is a shift in the damage costs as a function of the return period. The shift occurs approximately at the 10 year return period and can perhaps be related to the design criteria for sewer systems. Further, it was tested if the EAD estimation could be simplified by assuming a single unit cost per flooded area. The results indicate that within each catchment this may be a feasible approach. However the unit costs varies substantially between different case study areas. Hence it is not feasible to develop unit costs that can be used to calculate EAD, most likely because the urban landscape is too heterogeneous
    corecore