95 research outputs found
Comparison of short-segment monoaxial and polyaxial pedicle screw fixation combined with intermediate screws in traumatic thoracolumbar fractures: a finite element study and clinical radiographic review
OBJECTIVES: No studies have compared monoaxial and polyaxial pedicle screws with regard to the von Mises stress of the instrumentation, intradiscal pressures of the adjacent segment and adjacent segment degeneration. METHODS: Short-segment monoaxial/polyaxial pedicle screw fixation techniques were compared using finite element methods, and the redistributed T11-L1 segment range of motion, largest maximal von Mises stress of the instrumentation, and intradiscal pressures of the adjacent segment under displacement loading were evaluated. Radiographic results of 230 patients with traumatic thoracolumbar fractures treated with these fixations were reviewed, and the sagittal Cobb’s angle, vertebral body angle, anterior vertebral body height of the fractured vertebrae and adjacent segment degeneration were calculated and evaluated. RESULTS: The largest maximal values of the von Mises stress were 376.8 MPa for the pedicle screws in the short-segment monoaxial pedicle screw fixation model and 439.9 MPa for the rods in the intermediate monoaxial pedicle screw fixation model. The maximal intradiscal pressures of the upper adjacent segments were all greater than those of the lower adjacent segments. The maximal intradiscal pressures of the monoaxial pedicle screw fixation model were larger than those in the corresponding segments of the normal model. The radiographic results at the final follow-up evaluation showed that the mean loss of correction of the sagittal Cobb’s angle, vertebral body angle and anterior vertebral body height were smallest in the intermediate monoaxial pedicle screw fixation group. Adjacent segment degeneration was less likely to be observed in the intermediate polyaxial pedicle screw fixation group but more likely to be observed in the intermediate monoaxial pedicle screw fixation group. CONCLUSION: Smaller von Mises stress in the pedicle screws and lower intradiscal pressure in the adjacent segment were observed in the polyaxial screw model than in the monoaxial pedicle screw fixation spine models. Fracture-level fixation could significantly correct kyphosis and reduce correction loss, and adjacent segment degeneration was less likely to be observed in the intermediate polyaxial pedicle screw fixation group
Comparison of Single or Double Titanium Mesh Cage for Anterior Reconstruction After Total En Bloc Spondylectomy for Thoracic and Lumbar Spinal Tumors
Objective To compare the clinical efficacy of anterior column reconstruction using single or double titanium mesh cage (TMC) after total en bloc spondylectomy (TES) of thoracic and lumbar spinal tumors. Methods A retrospective cohort study was performed involving 39 patients with thoracic or lumbar spinal tumors. All patients underwent TES, followed by anterior reconstruction and screw-rod instrumentation via a posterior-only procedure. Twenty-two patients in group A were treated with a single TMC to reconstruct the anterior column, whereas 17 patients in group B were reconstructed with double TMCs. Results The overall follow-up is 20.5 ± 4.6 months. There is no significant difference between the 2 groups regarding age, sex, body mass index, tumor location, operative time, and intraoperative blood loss. The time for TMC placement was significantly shortened in the double TMCs group (5.2 ± 1.3 minutes vs. 15.6 ± 3.3 minutes, p = 0.004). Additionally, postoperative neural complications were significantly reduced with double TMCs (5/22 vs. 0/17, p = 0.046). The kyphotic Cobb angle and mean intervertebral height were significantly corrected in both groups (p ≤ 0.001), without obvious loss of correction at the last follow-up in either group. The bone fusion rates for single TMC and double TMCs were 77.3% and 76.5%, respectively. Conclusion Using 2 smaller TMCs instead of a single large one eases the placement of TMC by shortening the time and avoiding nerve impingement. Anterior column reconstruction with double TMC is a clinically feasible, and safe alternative following TES for thoracic and lumbar tumors
FERONIA interacts with ABI2-type phosphatases to facilitate signaling cross-talk between abscisic acid and RALF peptide in Arabidopsis
[EN] Receptor-like kinase FERONIA (FER) plays a crucial role in plant response to small molecule hormones [e.g., auxin and abscisic acid (ABA)] and peptide signals [e.g., rapid alkalinization factor (RALF)]. It remains unknown how FER integrates these different signaling events in the control of cell growth and stress responses. Under stress conditions, increased levels of ABA will inhibit cell elongation in the roots. In our previous work, we have shown that FER, through activation of the guanine nucleotide exchange factor 1 (GEF1)/4/10-Rho of Plant 11 (ROP11) pathway, enhances the activity of the phosphatase ABA Insensitive 2 (ABI2), a negative regulator of ABA signaling, thereby inhibiting ABA response. In this study, we found that both RALF and ABA activated FER by increasing the phosphorylation level of FER. The FER loss-of-function mutant displayed strong hypersensitivity to both ABA and abiotic stresses such as salt and cold conditions, indicating that FER plays a key role in ABA and stress responses. We further showed that ABI2 directly interacted with and dephosphorylated FER, leading to inhibition of FER activity. Several other ABI2-like phosphatases also function in this pathway, and ABA-dependent FER activation required PYRABACTIN RESISTANCE (PYR)/PYR1-LIKE (PYL)/REGULATORY COMPONENTS OF ABA RECEPTORS (RCAR)-A-type protein phosphatase type 2C (PP2CA) modules. Furthermore, suppression of RALF1 gene expression, similar to disruption of the FER gene, rendered plants hypersensitive to ABA. These results formulated a mechanism for ABA activation of FER and for cross-talk between ABA and peptide hormone RALF in the control of plant growth and responses to stress signals.We thank Dr. Alice Cheung, Dr. Daniel Moura, Grossniklaus Ueli, Dr. Jigang Li, and Dr. Nieng Yan for providing plant, ABI1 antibody, or plasmid materials, and Dr. Legong Li for assistance in laser confocal microscopy. This work was supported by grants from National Natural Science Foundation of China (NSFC-31400232, 31571444), the State Key Laboratory of Molecular Developmental Biology (2015-MDB-KF-12), the Fundamental Research Funds for the Central Universities of China, and a grant from the National Science Foundation.Chen, J.; Yu, F.; Liu, Y.; Du, C.; Li, X.; Zhu, S.; Wang, X.... (2016). FERONIA interacts with ABI2-type phosphatases to facilitate signaling cross-talk between abscisic acid and RALF peptide in Arabidopsis. Proceedings of the National Academy of Sciences. 113(37):E5519-E5527. https://doi.org/10.1073/pnas.1608449113SE5519E55271133
Force Analysis of a Circular Cylinder at Ununiformed Flow in a T Pipe Junction
Experimental and numerical investigations of force analysis acted on single circular cylinder in the T pipe junction with the effect of vanes are reported in this paper. Experiments are carried on in a small wind tunnel at five different velocity ratios (R) from 0.117 to 0.614. The mean pressure data acted on the cylinder are obtained and in turn the drag and lift. Vanes are installed at the junction to change the secondary flow in the branch duct and the angle is in the range of 90° ≤ φ ≤ 130°. Numerical studies which are validated by the experimental data help understand the flow structure for the analysis. It is found that in the T shape junction without vanes, the cylinder presents different surface mean pressure distributions at the different positions in the suction duct. As the increase of the distance from the junction to the cylinder center, the surface mean pressure distributions recover to the benchmark gradually which performs in the straight duct beforehand. Four feature points including the front/rear stagnation points and the separation points and the corresponding three divisions of flow region are analyzed in detail with the auxiliary numerical simulation of flow structure. Effect of the vanes with different angle is also discussed. Finally, the drag and lift coefficients acted on the cylinder with or without vanes are performed
- …