10 research outputs found

    Avaliação da contração de polimerização de três resinas compactáveis, medida por picnômetro a gás

    Get PDF
    Modern restorative dentistry has been playing an outstanding role lately since composite resins, allied to adhesive systems, have been widely applied on anterior and posterior teeth restorations. The evolution of composite resins has mostly been verified due to the improvement of their aesthetic behavior and the increase in their compressive and abrasive strengths. In spite of these developments, the polymerization shrinkage inherent to the material has been a major deficiency that, so far, has been impossible to avoid. Using a gas pycnometry, this research investigated the polymerization shrinkage of three packable composite resins: Filtek P60 (3M), Prodigy Condensable (Kerr), and SureFil (Dentsply/Caulk), varying the distance from the light source to the surface of the resins (2 mm or 10 mm). The pycnometer Accupyc 1330 (Micromeritics, USA) precisely records helium displacement, allowing fast and reliable measurements of the volume of composite resin immediately before and after polymerization, without interference of temperature or humidity. Results were not found to be statistically different for the three tested resins, either for 2 mm or 10 mm-distance from the light source to the composite surface.A Odontologia Restauradora moderna tem se destacado nos últimos anos e as resinas compostas, aliadas aos sistemas adesivos, têm sido muito empregadas para restaurações de dentes anteriores e posteriores. A evolução das resinas compostas tem sido constatada na melhoria do seu comportamento estético e no aumento da sua resistência à compressão e à abrasão. Apesar dos avanços mencionados, a contração de polimerização, inerente a esse material, continua sendo uma grande deficiência e, por enquanto, impossível de ser evitada. Nesta pesquisa a contração de polimerização de três resinas compostas compactáveis, Filtek P60 (3M), Prodigy Condensável (Kerr) e SureFil (Dentsply/Caulk), variando-se a distância entre a fonte de luz e a superfície das resinas em 2 mm e 10 mm, foi avaliada pelo método da picnometria a gás. O aparelho picnômetro Accupyc 1330 (Micromeritics, EUA) mede o deslocamento de gás hélio com grande precisão, permitindo medições rápidas e fiéis do volume das resinas compostas antes e após a polimerização, sem interferência da temperatura e da umidade. Os resultados mostraram que não houve diferenças estatisticamente significantes entre as três resinas avaliadas. Independentemente do tipo de resina composta, também não houve diferenças significantes para as distâncias de polimerização de 2 mm e 10 mm

    Finite elements study of the Flexi Post and Flexi Flange post systems in a maxillary central incisor

    Get PDF
    A utilização de pinos intra-radiculares tem se mostrado uma excelente alternativa para dentes endodonticamente tratados. Este trabalho teve como objetivo avaliar, utilizando o Método dos Elementos Finitos (MEF), como pinos intra-radiculares pré-fabricados metálicos podem alterar o padrão das tensões geradas de von Mises e de máxima tração e compressão na raiz dental. A comparação foi realizada entre os pinos pré-fabricados Flexi Post/Flexi Flange de aço inoxidável e titânio com preenchimento coronário em resina composta. Os pinos intra-radiculares foram fixados com um cimento resinoso e recobertos por uma coroa total cerâmica. A partir de fotografias da peça anatômica e dos pinos estudados, foram criados modelos matemáticos bidimensionais no programa MSC/Nastran 4.5 e, após aplicação de uma força de 100 N a 45 graus na superfície palatina dos modelos, foi avaliada a distribuição das tensões geradas. Com base nos resultados obtidos, pode-se concluir que os pinos intra-radiculares alteram o padrão das tensões geradas dependendo do desenho do pino intra-radicular e do tipo de material constituinte.The use of post and core systems has become an excellent alternative for restoring endodontically treated teeth. The aim of this study was to evaluate the von Mises, maximal compressive and tensile stresses distribution using the Finite Element Method (FEM) on human teeth restored with different post and core systems. The analysis was made on endodontically treated maxillary central incisors. The post systems used in this investigation were the stainless steel or titanium Flexi Post/Flexi Flange. Composite resin was used as core material and resin cement was the cement material of choice to seat a full porcelain crown. The bi-dimensional mathematical model was created from pictures taken from an intact human maxillary central incisor and prefabricated posts. This image was transferred to a personal computer in the MSC/Nastran 4.5 software. A static and linear analysis treatment was performed when a 45º load of 100 N was applied on the lingual surface of the tooth. Based on the results obtained, it can be concluded that the post design and its material can alter the stress pattern distribution

    Polymerization shrinkage evaluation of three packable composite resins using a gas pycnometer.

    Get PDF
    Modern restorative dentistry has been playing an outstanding role lately since composite resins, allied to adhesive systems, have been widely applied on anterior and posterior teeth restorations. The evolution of composite resins has mostly been verified due to the improvement of their aesthetic behavior and the increase in their compressive and abrasive strengths. In spite of these developments, the polymerization shrinkage inherent to the material has been a major deficiency that, so far, has been impossible to avoid. Using a gas pycnometry, this research investigated the polymerization shrinkage of three packable composite resins: Filtek P60 (3M), Prodigy Condensable (Kerr), and SureFil (Dentsply/Caulk), varying the distance from the light source to the surface of the resins (2 mm or 10 mm). The pycnometer Accupyc 1330 (Micromeritics, USA) precisely records helium displacement, allowing fast and reliable measurements of the volume of composite resin immediately before and after polymerization, without interference of temperature or humidity. Results were not found to be statistically different for the three tested resins, either for 2 mm or 10 mm-distance from the light source to the composite surface

    Reattachment Of Anterior Fractured Teeth: Effect Of Materials And Techniques On Impact Strength.

    No full text
    The reattachment of dental fragments, as a conservative treatment, should be the first choice to restore fractured teeth. Therefore, the aim of this study was to evaluate the effect of different materials and reattachment techniques on impact strength of bovine incisors. Standardized fragments were obtained when 80 crowns were sectioned 12 mm from the incisal edge. Teeth were mounted in PVC rings, embedded in acrylic resin and polyether to simulate bone support and periodontal ligament. Specimens were distributed in nine groups (n = 10), according to the reattachment technique (Direct bonding or Circumferential chamfer); the adhesive system (Single Bond or Clearfil SE Bond); and the intermediated material (Filtek Z350 Flow or Rely X CRA). Sound teeth composed the control group. Circumferential chamfer was prepared after the bonding of the fragment by means of a spherical point and filled with the composite Filtek Z250. The impact strength was evaluated in a universal testing machine Instron. A compressive load was applied at a crosshead speed of 500 mm min(-1) on the buccal surface, 2 mm from the incisal edge. Data were submitted to anova and Ryan-Einot-Gabriel-Welsch Multiple Range test (5%). Mean value of impact strength for control group was 64.8 Kgf. The fragment reattachment using Circumferential chamfer was significantly superior to Direct Bonding. The use of Single Bond significantly increased the impact strength when compared to the use of Clearfil SE. There was no significant difference among Rely X and Filtek X350 Flow. No technique or material, when individually considered, was capable of achieving the mechanical strength of the sound teeth; however, the association of reattachment technique Circumferential chamfer with bonding system Single Bond could approximate the immediate impact strength of the restored teeth to that observed in the sound teeth.26315-2
    corecore