593 research outputs found

    Single injection dual phase CBCT technique ameliorates results of trans-arterial chemoembolization for hepatocellular cancer

    Get PDF
    Cone-beam CT (CBCT) application to the field of trans-arterial chemoembolization has been recently the focus of several researches. This imaging modality is performed with a rotation of the C-arm around the patient, without needs of patient repositioning. Datasets are immediately processed, obtaining volumetric CT-like images with the possibility of post-processing and reconstruction of images. Dual phase CBCT recently introduced in clinical practice consists in a first arterial acquisition followed by a delayed acquisition corresponding to a venous phase. The introduction of this feature has overcome the limit of single-phase acquisitions, allowing lesions characterization. Moreover these recent advantages have several intra-procedural implications. Detailed technical and acquisition parameters will be widely exposed in this review with particular attention to: catheter positioning, acquisition delay, injection parameters, patient positioning and contrast dilution. Comparison with standard of practice second line imaging [multidetector computer tomography (MDCT) and MDCT/arteriography] demonstrate the capability of detecting occult nodules providing some clinical implications thus potentially identifying a sub set of patients with aggressive disease behaviour. Other intra-procedural advantages of dual phase CBCT usage consist in a better tumor feeder visualization, reduction of proper DSA and fluoroscopic time, suggestion the presence of an extrahepatic parasitic feeder thus resulting in a more accurate treatment. Finally, the volumetrical intraprocedural evaluation of accumulation of embolic agent has proved to be correlate with treatment response if compared with MRI

    The GRAAL high resolution BGO calorimeter and its energy calibration and monitoring system

    Get PDF
    We describe the electromagnetic calorimeter built for the GRAAL apparatus at the ESRF. Its monitoring system is presented in detail. Results from tests and the performance obtained during the first GRAAL experiments are given. The energy calibration accuracy and stability reached is a small fraction of the intrinsic detector resolution.Comment: 19 pages, 14 figures, submitted to Nuclear Instruments and Method

    Open versus laparoscopic splenectomy a meta-analysis of larger series

    Get PDF
    Background: Minimally invasive surgery for elective splenectomy has become a routine procedure in all laparoscopic centers. After first case series, many groups has published comparative studies between open and laparoscopic approach. For this purpose, a meta-analysis investigating comparative studies of open versus laparoscopic approach for splenectomy was performed.Methods: All kinds of manuscripts were reviewed, and we included the only studies with a laparoscopic group number >= 50 cases.Results: The literature search, performed until December 31, 2019, identified a total of 564 records. After full-text analysis, twelve studies were included in the meta-analysis. Operative time was higher for the laparoscopic group in all but one study. The length of stay, morbidity and mortality were less frequent in the laparoscopic group.Conclusions: The gain of shorter hospital-stay associated with the good outcomes suggests performing splenectomy by a laparoscopic procedure

    Laparoscopy in liver transplantation: The future has arrived

    Get PDF
    In the last two decades, laparoscopy has revolutionized the field of surgery. Many procedures previously performed with an open access are now routinely carried out with the laparoscopic approach. Several advantages are associated with laparoscopic surgery compared to open procedures: reduced pain due to smaller incisions and hemorrhaging, shorter hospital length of stay, and a lower incidence of wound infections. Liver transplantation (LT) brought a radical change in life expectancy of patients with hepatic endstage disease. Today, LT represents the standard of care for more than fifty hepatic pathologies, with excellent results in terms of survival. Surely, with laparoscopy and LT being one of the most continuously evolving challenges in medicine, their recent combination has represented an astonishing scientific progress. The intent of the present paper is to underline the current role of diagnostic and therapeutic laparoscopy in patients waiting for LT, in the living donor LT and in LT recipients

    Precise Measurement of Sigma Beam Asymmetry for Positive Pion Photoproduction on the Proton from 800 to 1500 Mev

    Full text link
    The Sigma beam asymmetry for positive pion photoproduction on the proton has been measured over an angular range of 40-170 deg at photon energies from 0.8 to 1.5 GeV. The resulting data set includes 237 accurate points, 136 of these belonging to an almost unexplored domain above 1.05 GeV. Data of such high precision provide severe constraints for partial wave analyses. The influence of this experiment on the GW multipole analysis is demonstrated. Significant changes are found in multipoles connected to the S31(1620) and P13(1720) resonances. Comparisons using the MAID analysis are also presented.Comment: 11 pages, 4 eps figures. to be published in Physics Letters

    Differential cross section measurement of eta photoproduction on the proton from threshold to 1100 MeV

    Get PDF
    The differential cross section for the reaction p(gamma, eta p) has been measured from threshold to 1100 MeV photon laboratory energy. For the first time, the region of the S11(1535) resonance is fully covered in a photoproduction experiment and allows a precise extraction of its parameters at the photon point. Above 1000 MeV, S-wave dominance vanishes while a P-wave contribution is observed whose nature will have to be clarified. These high precision data together with the already measured beam asymmetry data will provide stringent constraints on the extraction of new couplings of baryon resonances to the eta meson.Comment: 10 pages, 5 figures, submitted to Phys. Letters B. Typos corrected. Some more information on the S11(1535) parameter
    corecore