10 research outputs found

    Efeito da ciclagem térmica sobre a resistência de união entre uma cerâmica infiltrada com vidro e um cimento resinoso

    Get PDF
    The aim of the present study was to evaluate the effect of thermocycling on the bond strength between the surface of the glass-infiltrated alumina ceramic In-Ceram (VITA) and the Panavia F resin cement (Kuraray CO.). Four 5x6x6mm In-Ceram blocks were obtained. One of the 6x6mm faces of each block was conditioned with Cojet - System (tribochemical silica coating, ESPE-3M) and then luted under a constant 750g pressure with Panavia F cement to another identical face of a resin composit block (Clearfil AP-X, Kuraray) obtained by reproduction of the ceramic one from Express (3M) addition curing silicone impressions. The four sets so formed by ceramic, luting cement and resin have been each one serially sectioned in 20 sticks so that the adhesive surface in each presented 1mm² of area. The samples were divided in 2 groups (n=10): G1- stored for 7 days in deionized water at 36 ± 2ºC; G2 - thermocycled 1500 times between 5 and 55ºC dwell times. The microtensile tests were accomplished in an universal testing machine (EMIC) at a crosshead speed of 0,5 mm/min. The results showed that the mean tensile bond strength values (MPa) for the group G2: (22,815 ± 5,254) had not statistically differ of the values of group G1: (25,628 ± 3,353) (t = 1,427; gl = 18; p-value = 0,171), at the level of a= 5%. It can be concluded that the thermocycling technique used in the present experiment had not produced statistically significant differences between the bond strength results of the specimens obtained by the two used techniques.O objetivo deste estudo foi avaliar o efeito da ciclagem térmica sobre a resistência de adesão entre a superfície da cerâmica In-Ceram Alumina (VITA) e o cimento resinoso Panavia F (Kuraray). Foram confeccionados quatro blocos de cerâmica In-Ceram com dimensões de 5x6x6mm. Uma das faces com 6x6mm de cada bloco cerâmico, após condicionamento com o sistema Cojet (ESPE-3M) (jateamento com óxido de alumínio/jateamento com óxido de sílica/ silanização) foi cimentada com Panavia F, sob peso constante de 750g, a outro bloco idêntico de resina composta Clearfil AP-X (Kuraray). Os blocos de resina foram obtidos por meio de duplicação daqueles de cerâmica a partir de moldes com silicona de adição Express (3M). Os quatro conjuntos formados por cerâmica, cimento e resina foram seccionados em 20 corpos-de-prova com forma de palitos, de modo que a região adesiva apresentasse 1mm² de área. Dois grupos (n=10) foram constítuidos: G1- estocagem por 7 dias em água deionizada à 36 ± 2ºC; G2- 1500 ciclos entre 5ºC e 55ºC com intervalos de 30 segundos. A seguir, foi realizado o teste de microtração em máquina de ensaio universal (EMIC) com velocidade de 0,5 mm/min. Os resultados mostraram que os valores médios de tensão de ruptura (MPa) para o grupo G2: (22,815 ± 5,254) não tiveram diferenças estatisticamente significantes daqueles do grupo G1: (25,628 ± 3,353) (t= 1,427; gl = 18; p-valor = 0,171), ao nível de significância de 5%. A partir destes resultados, entendemos lícito concluir que o efeito da ciclagem térmica não produziu alterações estatisticamente significantes nos valores da resistência adesiva

    Precisão de duas técnicas de esplintagem com resina acrílica de transferentes para próteses sobre implantes

    Get PDF
    Dois métodos de esplintagem com resina acrílica de transferentes quadrados usados para moldagem em próteses sobre implantes foram avaliados. Dois implantes foram posicionados no centro de um bloco de poliuretano, e sobre eles foram instaladas pilares protéticos "microunit". Dezesseis amostras foram fabricadas neste modelo, cada uma empregando dois transferentes quadrados, rigidamente conectados com resina acrílica autopolimerizável. Metade das amostras formaram o grupo 1 (n=8). Para o grupo 2 (n=8) a outra metade das amostras foi armazenada durante 24 horas. Neste grupo a esplintagem foi seccionada e os dois segmentos foram unidos novamente. Quatro extensômetros (Excel Sensores Ltda.) posicionados ao redor dos implantes registraram as deformações geradas por cada amostra. Os sinais foram amplificados e transferidos, para então serem registrados e analisados pelo software (AqDados AqAnalysis). Para o grupo 1, as mensurações foram feitas após a polimerização do bloco de resina acrílica; para o grupo 2 foram realizadas após a nova união dos segmentos. A análise estatística foi realizada empregado-se o teste t de Student para amostras independentes (5%). Diferença significante (pTwo acrylic resin splinted techniques used for direct implant impression were assessed for accuracy in a laboratory model that simulated clinical practice. Two implants were embedded in the center of a polyurethane block. Microunit abutments were placed on the implants. Sixteen samples were fabricated on this model, using two square transfer copings rigidly connected to each other with autopolymerizing acrylic resin. Half the samples formed group 1 (n=8). For group 02 (n=8) the other half were stored at ambient conditions for 24 hours; then, the acrylic resin splint was sectioned in this group, and the segments were reconnected. Strain measurements were performed by four strain gauges (Excel Sensores Ltda.) placed on the superior surface of the polyurethane block. For group 1, measurements were made after the polymerization of the acrylic resin splint; for group 2 after the segments were reconnected. Student’s t-test for independent samples, with statistical significance at 5%, was applied to analyze the data. Significant difference (p< .05) was found between the 2 techniques. The 1-piece acrylic resin splinted technique (G1) produced significantly higher strain values (143.25 ±53.48mµ) than the other technique (G2/ 70.83mµ ±29.03mµ). It was concluded that the acrylic resin splinted technique with separation and reconnection after 24 hours was significantly more accurate than the 1-piece acrylic resin splinted technique

    Heat treatment of pre-hydrolyzed silane increases adhesion of phosphate monomer-based resin cement to glass ceramic

    Full text link
    This study evaluated the influence of different forms of heat treatment on a pre-hydrolyzed silane to improve the adhesion of phosphate monomer-based (MDP) resin cement to glass ceramic. Resin and feldspathic ceramic blocks (n=48, n=6 for bond test, n=2 for microscopy) were randomly divided into 6 groups and subject to surface treatments: G1: Hydrofluoric acid (HF) 9.6% for 20 s + Silane + MDP resin cement (Panavia F); G2: HF 9.6% for 20 s + Silane + Heat Treatment (oven) + Panavia F; G3: Silane + Heat Treatment (oven) + Panavia F; G4: HF 9.6% for 20 s + Silane + Heat Treatment (hot air) + Panavia F; G5: Silane + Heat Treatment (hot air) + Panavia F; G6: Silane + Panavia F. Microtensile bond strength (MTBS) test was performed using a universal testing machine (1 mm/min). After debonding, the substrate and adherent surfaces were analyzed using stereomicroscope and scanning electron microscope (SEM) to categorize the failure types. Data were analyzed statistically using two-way test ANOVA and Tukey's test (=0.05). Heat treatment of the silane containing MDP, with prior etching with HF (G2: 13.15 ± 0.89a; G4: 12.58 ± 1.03a) presented significantly higher bond strength values than the control group (G1: 9.16 ± 0.64b). The groups without prior etching (G3: 10.47 ± 0.70b; G5: 9.47 ± 0.32b) showed statistically similar bond strength values between them and the control group (G1). The silane application without prior etching and heat treatment resulted in the lowest mean bond strength (G6: 8.05 ± 0.37c). SEM analysis showed predominantly adhesive failures and EDS analysis showed common elements of spectra (Si, Na, Al, K, O, C) characterizing the microstructure of the glass-ceramic studied. Heat treatment of the pre-hydrolyzed silane containing MDP in an oven at 100 °C for 2 min or with hot air application at 50 ± 5 ºC for 1 min, was effective in increasing the bond strength values between the ceramic and resin cement containing MDP

    Comparação da rugosidade superficial de resinas compostas após polimento imediato e tardio

    No full text
    Objetivo: Comparar os efeitos do polimento imediato e tardio (após sete dias) sobre a rugosidade superficial de quatro resinas compostas diretas: Suprafill, Opallis, Filtek Z250 e Filtek Z350. Materiais e Métodos: Quarenta espécimes (n=10) foram confeccionados a partir de uma matriz metálica de alumínio (5 mm Ø e 2mm de espessura). Cada grupo de resina composta foi submetido a dois tipos de polimento de forma aleatória. 5 amostras de cada grupo teve seu polimento realizado imediatamente e os outros 5 corpos de prova aguardaram sete dias para a realização do polimento com discos de óxido de alumínio Sof-Lex em todas as suas granulometrias diferentes. A rugosidade foi avaliada por meio de rugosímetro Surftest 211, série 178 (velocidade de 0,5 mm/s; distância de 0,25mm; ajuste em Ra µm). Os dados foram submetidos à análise estatística com o Teste paramétrico t de student pareado. Resultados: Os valores de p foram para G1=1 (0,58/0,58mm); G2=0,44 (0,59/0,51mm); G3=0,012 (0,6/0,95mm); e G4=0,33 (0,56/0,48mm), ou seja, houve diferença estatisticamente significativa apenas o G3, sendo pior o seu desempenho de lisura superficial após sete dias. Conclusão: não houve melhoria estatística dos resultados de rugosidade superficial após polimento tardio em relação ao polimento imediato (p>0,05)

    Efficacy of prostheses bonding using silane incorporated to universal adhesives or applied separately: A systematic review

    No full text
    Currently, the long-term success of esthetic rehabilitation with ceramics is required. Hence, professional knowledge about the most indicated dental material for each clinical situation as well as its usage protocol is essential. The aim of this systematic review of clinical and laboratorial studies was to compare the bond strength of prostheses using silane incorporated to universal adhesives or applied separately. The literature search in databases “Cochrane Library,” “MEDLINE,” “Web of Science,” “Scopus,” “LILACS,” “Scielo,” and “Google Scholar” was based on the keywords “Silane;” “Silanes;” “Silane coupling agent;” “Universal adhesive;” and “Universal adhesives.” A total of five articles were included in this review. In general, the studies showed better results for ceramic etching with hydrofluoric acid and application of silane separately to the universal adhesive. As a conclusion, the treatment with pure silane or as an additional pretreatment with universal adhesives improved the bond strength of glass ceramics. Hence, higher shear bond strength can be achieved, resulting in treatment longevity

    Effect of thermocycling on the bond strength of a glass-infiltrated ceramic and a resin luting cement Efeito da ciclagem térmica sobre a resistência de união entre uma cerâmica infiltrada com vidro e um cimento resinoso

    No full text
    The aim of the present study was to evaluate the effect of thermocycling on the bond strength between the surface of the glass-infiltrated alumina ceramic In-Ceram (VITA) and the Panavia F resin cement (Kuraray CO.). Four 5x6x6mm In-Ceram blocks were obtained. One of the 6x6mm faces of each block was conditioned with Cojet - System (tribochemical silica coating, ESPE-3M) and then luted under a constant 750g pressure with Panavia F cement to another identical face of a resin composit block (Clearfil AP-X, Kuraray) obtained by reproduction of the ceramic one from Express (3M) addition curing silicone impressions. The four sets so formed by ceramic, luting cement and resin have been each one serially sectioned in 20 sticks so that the adhesive surface in each presented 1mm² of area. The samples were divided in 2 groups (n=10): G1- stored for 7 days in deionized water at 36 ± 2ºC; G2 - thermocycled 1500 times between 5 and 55ºC dwell times. The microtensile tests were accomplished in an universal testing machine (EMIC) at a crosshead speed of 0,5 mm/min. The results showed that the mean tensile bond strength values (MPa) for the group G2: (22,815 ± 5,254) had not statistically differ of the values of group G1: (25,628 ± 3,353) (t = 1,427; gl = 18; p-value = 0,171), at the level of a= 5%. It can be concluded that the thermocycling technique used in the present experiment had not produced statistically significant differences between the bond strength results of the specimens obtained by the two used techniques.<br>O objetivo deste estudo foi avaliar o efeito da ciclagem térmica sobre a resistência de adesão entre a superfície da cerâmica In-Ceram Alumina (VITA) e o cimento resinoso Panavia F (Kuraray). Foram confeccionados quatro blocos de cerâmica In-Ceram com dimensões de 5x6x6mm. Uma das faces com 6x6mm de cada bloco cerâmico, após condicionamento com o sistema Cojet (ESPE-3M) (jateamento com óxido de alumínio/jateamento com óxido de sílica/ silanização) foi cimentada com Panavia F, sob peso constante de 750g, a outro bloco idêntico de resina composta Clearfil AP-X (Kuraray). Os blocos de resina foram obtidos por meio de duplicação daqueles de cerâmica a partir de moldes com silicona de adição Express (3M). Os quatro conjuntos formados por cerâmica, cimento e resina foram seccionados em 20 corpos-de-prova com forma de palitos, de modo que a região adesiva apresentasse 1mm² de área. Dois grupos (n=10) foram constítuidos: G1- estocagem por 7 dias em água deionizada à 36 ± 2ºC; G2- 1500 ciclos entre 5ºC e 55ºC com intervalos de 30 segundos. A seguir, foi realizado o teste de microtração em máquina de ensaio universal (EMIC) com velocidade de 0,5 mm/min. Os resultados mostraram que os valores médios de tensão de ruptura (MPa) para o grupo G2: (22,815 ± 5,254) não tiveram diferenças estatisticamente significantes daqueles do grupo G1: (25,628 ± 3,353) (t= 1,427; gl = 18; p-valor = 0,171), ao nível de significância de 5%. A partir destes resultados, entendemos lícito concluir que o efeito da ciclagem térmica não produziu alterações estatisticamente significantes nos valores da resistência adesiva

    NEOTROPICAL CARNIVORES: a data set on carnivore distribution in the Neotropics

    No full text
    Mammalian carnivores are considered a key group in maintaining ecological health and can indicate potential ecological integrity in landscapes where they occur. Carnivores also hold high conservation value and their habitat requirements can guide management and conservation plans. The order Carnivora has 84 species from 8 families in the Neotropical region: Canidae; Felidae; Mephitidae; Mustelidae; Otariidae; Phocidae; Procyonidae; and Ursidae. Herein, we include published and unpublished data on native terrestrial Neotropical carnivores (Canidae; Felidae; Mephitidae; Mustelidae; Procyonidae; and Ursidae). NEOTROPICAL CARNIVORES is a publicly available data set that includes 99,605 data entries from 35,511 unique georeferenced coordinates. Detection/non-detection and quantitative data were obtained from 1818 to 2018 by researchers, governmental agencies, non-governmental organizations, and private consultants. Data were collected using several methods including camera trapping, museum collections, roadkill, line transect, and opportunistic records. Literature (peer-reviewed and grey literature) from Portuguese, Spanish and English were incorporated in this compilation. Most of the data set consists of detection data entries (n = 79,343; 79.7%) but also includes non-detection data (n = 20,262; 20.3%). Of those, 43.3% also include count data (n = 43,151). The information available in NEOTROPICAL CARNIVORES will contribute to macroecological, ecological, and conservation questions in multiple spatio-temporal perspectives. As carnivores play key roles in trophic interactions, a better understanding of their distribution and habitat requirements are essential to establish conservation management plans and safeguard the future ecological health of Neotropical ecosystems. Our data paper, combined with other large-scale data sets, has great potential to clarify species distribution and related ecological processes within the Neotropics. There are no copyright restrictions and no restriction for using data from this data paper, as long as the data paper is cited as the source of the information used. We also request that users inform us of how they intend to use the data

    NEOTROPICAL ALIEN MAMMALS: a data set of occurrence and abundance of alien mammals in the Neotropics

    No full text
    Biological invasion is one of the main threats to native biodiversity. For a species to become invasive, it must be voluntarily or involuntarily introduced by humans into a nonnative habitat. Mammals were among first taxa to be introduced worldwide for game, meat, and labor, yet the number of species introduced in the Neotropics remains unknown. In this data set, we make available occurrence and abundance data on mammal species that (1) transposed a geographical barrier and (2) were voluntarily or involuntarily introduced by humans into the Neotropics. Our data set is composed of 73,738 historical and current georeferenced records on alien mammal species of which around 96% correspond to occurrence data on 77 species belonging to eight orders and 26 families. Data cover 26 continental countries in the Neotropics, ranging from Mexico and its frontier regions (southern Florida and coastal-central Florida in the southeast United States) to Argentina, Paraguay, Chile, and Uruguay, and the 13 countries of Caribbean islands. Our data set also includes neotropical species (e.g., Callithrix sp., Myocastor coypus, Nasua nasua) considered alien in particular areas of Neotropics. The most numerous species in terms of records are from Bos sp. (n = 37,782), Sus scrofa (n = 6,730), and Canis familiaris (n = 10,084); 17 species were represented by only one record (e.g., Syncerus caffer, Cervus timorensis, Cervus unicolor, Canis latrans). Primates have the highest number of species in the data set (n = 20 species), partly because of uncertainties regarding taxonomic identification of the genera Callithrix, which includes the species Callithrix aurita, Callithrix flaviceps, Callithrix geoffroyi, Callithrix jacchus, Callithrix kuhlii, Callithrix penicillata, and their hybrids. This unique data set will be a valuable source of information on invasion risk assessments, biodiversity redistribution and conservation-related research. There are no copyright restrictions. Please cite this data paper when using the data in publications. We also request that researchers and teachers inform us on how they are using the data
    corecore