19 research outputs found

    An automated, 0.5 Hz nano-foil target positioning system for intense laser plasma experiments

    Get PDF
    We report on a target system supporting automated positioning of nano-targets with a precision resolution of in three dimensions. It relies on a confocal distance sensor and a microscope. The system has been commissioned to position nanometer targets with 1Hz repetition rate. Integrating our prototype into the table-top ATLAS 300 TW-laser system at the Laboratory for Extreme Photonics in Garching, we demonstrate the operation of a 0.5Hz laser-driven proton source with a shot-to-shot variation of the maximum energy about 27% for a level of confidence of 0.95. The reason of laser shooting experiments operated at 0.5Hz rather than 1Hz is because the synchronization between the nano-foil target positioning system and the laser trigger needs to improve.DFG Cluster of Excellence Munich-Centre for Advanced Photonics (MAP); Centre for Advanced Laser Applications; China Scholarship [201508080084]SCI(E)ARTICLE

    I-BEAT: Ultrasonic method for online measurement of the energy distribution of a single ion bunch

    Get PDF
    The shape of a wave carries all information about the spatial and temporal structure of its source, given that the medium and its properties are known. Most modern imaging methods seek to utilize this nature of waves originating from Huygens' principle. We discuss the retrieval of the complete kinetic energy distribution from the acoustic trace that is recorded when a short ion bunch deposits its energy in water. This novel method, which we refer to as Ion-Bunch Energy Acoustic Tracing (I-BEAT), is a refinement of the ionoacoustic approach. With its capability of completely monitoring a single, focused proton bunch with prompt readout and high repetition rate, I-BEAT is a promising approach to meet future requirements of experiments and applications in the field of laser-based ion acceleration. We demonstrate its functionality at two laser-driven ion sources for quantitative online determination of the kinetic energy distribution in the focus of single proton bunches

    An automatic laser beam delivery alignment for LEX and CALA

    No full text

    Ionoacoustic detection of swift heavy ions

    No full text
    The maximum energy loss (Bragg peak) located near the end of range is a characteristic feature of ion stopping in matter, which generates an acoustic pulse, if ions are deposited into a medium in adequately short bunches. This so-called ionoacoustic effect has been studied for decades, mainly for astrophysical applications, and it has recently found renewed interest in proton therapy for precise range measurements in tissue. After detailed preparatory studies with 20 MeV protons at the MLL tandem accelerator, ionoacoustic range measurements were performed in water at the upgraded SIS18 synchrotron of GSI with 238U and 124Xe ion beams of energy about 300 MeV/u, and 12C ions of energy about 200 MeV/u using fast beam extraction to get 1 microsecond pulse lengths. Acoustic signals were recorded in axial geometry by standard piezo-based transducers at a 500 kHz mean frequency and evaluated in both the time and frequency domains. The resulting ranges for the different ions and energies were found to agree with Geant4 simulations as well as previous measurements to better than 1%. Given the high accuracy provided by ionoacoustic range measurements in water and their relative simplicity, we propose this new method for stopping power measurements for heavy ions at GeV energies and above. Our experimental results clearly demonstrate the potential of an ionoacoustic particle monitor especially for very intense heavy ion beams foreseen at future accelerator facilities.Comment: 22 pages, 15 figures, 3 tables, submitted to Nucl Instr Meth

    Ionoacoustic characterization of the proton Bragg peak with submillimeter accuracy.

    No full text
    PURPOSE: Range verification in ion beam therapy relies to date on nuclear imaging techniques which require complex and costly detector systems. A different approach is the detection of thermoacoustic signals that are generated due to localized energy loss of ion beams in tissue (ionoacoustics). Aim of this work was to study experimentally the achievable position resolution of ionoacoustics under idealized conditions using high frequency ultrasonic transducers and a specifically selected probing beam. METHODS: A water phantom was irradiated by a pulsed 20 MeV proton beam with varying pulse intensity and length. The acoustic signal of single proton pulses was measured by different PZT-based ultrasound detectors (3.5 and 10 MHz central frequencies). The proton dose distribution in water was calculated by Geant4 and used as input for simulation of the generated acoustic wave by the matlab toolbox k-WAVE. RESULTS: In measurements from this study, a clear signal of the Bragg peak was observed for an energy deposition as low as 10(12) eV. The signal amplitude showed a linear increase with particle number per pulse and thus, dose. Bragg peak position measurements were reproducible within ±30 μm and agreed with Geant4 simulations to better than 100 μm. The ionoacoustic signal pattern allowed for a detailed analysis of the Bragg peak and could be well reproduced by k-WAVE simulations. CONCLUSIONS: The authors have studied the ionoacoustic signal of the Bragg peak in experiments using a 20 MeV proton beam with its correspondingly localized energy deposition, demonstrating submillimeter position resolution and providing a deep insight in the correlation between the acoustic signal and Bragg peak shape. These results, together with earlier experiments and new simulations (including the results in this study) at higher energies, suggest ionoacoustics as a technique for range verification in particle therapy at locations, where the tumor can be localized by ultrasound imaging. This acoustic range verification approach could offer the possibility of combining anatomical ultrasound and Bragg peak imaging, but further studies are required for translation of these findings to clinical application

    Experimental demonstration of accurate Bragg peak localization with ionoacoustic tandem phase detection (iTPD).

    Get PDF
    Accurate knowledge of the exact stopping location of ions inside the patient would allow full exploitation of their ballistic properties for patient treatment. The localized energy deposition of a pulsed particle beam induces a rapid temperature increase of the irradiated volume and leads to the emission of ionoacoustic (IA) waves. Detecting the time-of-flight (ToF) of the IA wave allows inferring information on the Bragg peak location and can henceforth be used for in-vivo range verification. A challenge for IA is the poor signal-to-noise ratio at clinically relevant doses and viable machines. We present a frequency-based measurement technique, labeled as ionoacoustic tandem phase detection (iTPD) utilizing lock-in amplifiers. The phase shift of the IA signal to a reference signal is measured to derive the ToF. Experimental IA measurements with a 3.5 MHz lead zirconate titanate (PZT) transducer and lock-in amplifiers were performed in water using 22 MeV proton bursts. A digital iTPD was performed in-silico at clinical dose levels on experimental data obtained from a clinical facility and secondly, on simulations emulating a heterogeneous geometry. For the experimental setup using 22 MeV protons, a localization accuracy and precision obtained through iTPD deviates from a time-based reference analysis by less than 15 mu m. Several methodological aspects were investigated experimentally in systematic manner. Lastly, iTPD was evaluated in-silico for clinical beam energies indicating that iTPD is in reach of sub-mm accuracy for fractionated doses < 5 Gy. iTPD can be used to accurately measure the ToF of IA signals online via its phase shift in frequency domain. An application of iTPD to the clinical scenario using a single pulsed beam is feasible but requires further development to reach <1 Gy detection capabilities
    corecore