13,253 research outputs found

    Spectrum Analysis of Bright Kepler late B- to early F- Stars

    Full text link
    The Kepler satellite mission delivers single band-pass light curves of a huge number of stars observed in the Cygnus-Lyra region opening a new window for asteroseismology. In order to accomplish one of the preconditions for the asteroseismic modelling of the stars, we aim to derive fundamental parameters and individual abundances for a sample of 18 Gamma Dor (GD)/Delta Sct (DSct) and 8 SPB/beta Cep candidate stars in the Kepler satellite field of view. We use the spectral synthesis method to model newly obtained, high-resolution spectra of 26 stars in order to derive their fundamental parameters and individual abundances. The stars are then placed into the log(Teff)-log(g) diagram and the obtained spectroscopic classification is compared to the existing photometric one. For hot stars, the KIC temperatures appear to be systematically underestimated, in agreement with previous findings. We also find that the temperatures derived from our spectra agree reasonably well with those derived from the SED fitting. According to their position in the log(Teff)-log(g) diagram, two stars are expected GD stars, four stars are expected DSct stars, and four stars are possibly DSct stars at the blue edge of the instability strip. Two stars are confirmed SPB variables, and one star falls into the SPB instability region but its parameters might be biased by binarity. Two of the four stars that fall into the DSct instability region show GD-type oscillation in their light curves implying that GD-like oscillations are much more common among the DSct stars than is theoretically expected. Moreover, one of the stars located at the hot border of the DSct instability strip is classified as DSct-GD hybrid pulsator from its light curve analysis. Given that these findings are fully consistent with recent investigations, we conclude that a revision of the GD and DSct instability strips is essential.Comment: 14 pages, 14 figures, 6 tables; accepted for publication in MNRA

    Robot-Mediated Interviews with Children : What do potential users think?

    Get PDF
    Luke Wood, Hagen Lehmann, Kerstin Dautenhahn, Ben Robins, Austen Rayner, and Dag Syrdal, ‘Robot-Mediated Interviews with Children: What do potential users think?’, paper presented at the 50th Annual Convention of the Society for the Study of Artificial Intelligence and the Simulation of Behaviour, 1 April 2014 – 4 April 2014, London, UK.When police officers are conducting interviews with children, some of the disclosures can be quite shocking. This can make it difficult for an officer to maintain their composure without subtly indicating their shock to the child, which can in turn impede the information acquisition process. Using a robotic interviewer could eliminate this problem as the behaviours and expressions of the robot can be consciously controlled. To date research investigating the potential of Robot-Mediated Interviews has focused on establishing whether children will respond to robots in an interview scenario and if so how well. The results of these studies indicate that children will talk to a robot in an interview scenario in a similar way to which they talk to a human interviewer. However, in order to test if this approach would work in a real world setting, it is important to establish what the experts (e.g. specialist child interviewers) would require from the system. To determine the needs of the users we conducted a user panel with a group of potential real world users to gather their views of our current system and find out what they would require for the system to be useful to them. The user group we worked with consisted of specialist child protection police officers based in the UK. The findings from this panel suggest that a Robot-Mediated Interviewing system would need to be more flexible than our current system in order to respond to unpredictable situations and paths of investigation. This paper gives an insight into what real world users would need from a Robot-Mediated Interviewing system

    A superfluid hydrodynamic model for the enhanced moments of inertia of molecules in liquid 4He

    Full text link
    We present a superfluid hydrodynamic model for the increase in moment of inertia, ΔI\Delta I, of molecules rotating in liquid 4^4He. The static inhomogeneous He density around each molecule (calculated using the Orsay-Paris liquid 4^4He density functional) is assumed to adiabatically follow the rotation of the molecule. We find that the ΔI\Delta I values created by the viscousless and irrotational flow are in good agreement with the observed increases for several molecules [ OCS, (HCN)2_2, HCCCN, and HCCCH3_3 ]. For HCN and HCCH, our model substantially overestimates ΔI\Delta I. This is likely to result from a (partial) breakdown of the adiabatic following approximation.Comment: 4 pages, 1 eps figure, corrected version of published paper. Erratum has been submitted for change

    Self-Trapped Exciton Defects in a Charge Density Wave: Electronic Excitations of BaBiO3

    Full text link
    In the previous paper, it was shown that holes doped into BaBiO3 self-trap as small polarons and bipolarons. These point defects are energetically favorable partly because they undo locally the strain in the charge-density-wave (Peierls insulator) ground state. In this paper the neutral excitations of the same model are discussed. The lowest electronic excitation is predicted to be a self-trapped exciton, consisting of an electron and a hole located on adjacent Bi atoms. This excitation has been seen experimentally (but not identified as such) via the Urbach tail in optical absorption, and the multi-phonon spectrum of the ``breathing mode'' seen in Raman scattering. These two phenomena occur because of the Franck-Condon effect associated with oxygen displacement in the excited state.Comment: 5 pages with 7 embedded figures. See also cond-mat/0108089 on polarons and bipolarons in BaBiO3 contains background informatio

    Pricing Multi-Unit Markets

    Full text link
    We study the power and limitations of posted prices in multi-unit markets, where agents arrive sequentially in an arbitrary order. We prove upper and lower bounds on the largest fraction of the optimal social welfare that can be guaranteed with posted prices, under a range of assumptions about the designer's information and agents' valuations. Our results provide insights about the relative power of uniform and non-uniform prices, the relative difficulty of different valuation classes, and the implications of different informational assumptions. Among other results, we prove constant-factor guarantees for agents with (symmetric) subadditive valuations, even in an incomplete-information setting and with uniform prices

    Improved Visualization of the Necrotic Zone after Microwave Ablation Using Computed Tomography Volume Perfusion in an In Vivo Porcine Model

    Get PDF
    After hepatic microwave ablation, the differentiation between fully necrotic and persistent vital tissue through contrast enhanced CT remains a clinical challenge. Therefore, there is a need to evaluate new imaging modalities, such as CT perfusion (CTP) to improve the visualization of coagulation necrosis. MWA and CTP were prospectively performed in five healthy pigs. After the procedure, the pigs were euthanized, and the livers explanted. Orthogonal histological slices of the ablations were stained with a vital stain, digitalized and the necrotic core was segmented. CTP maps were calculated using a dual-input deconvolution algorithm. The segmented necrotic zones were overlaid on the DICOM images to calculate the accuracy of depiction by CECT/CTP compared to the histological reference standard. A receiver operating characteristic analysis was performed to determine the agreement/true positive rate and disagreement/false discovery rate between CECT/CTP and histology. Standard CECT showed a true positive rate of 81% and a false discovery rate of 52% for display of the coagulation necrosis. Using CTP, delineation of the coagulation necrosis could be improved significantly through the display of hepatic blood volume and hepatic arterial blood flow (p < 0.001). The ratios of true positive rate/false discovery rate were 89%/25% and 90%/50% respectively. Other parameter maps showed an inferior performance compared to CECT

    Effizienter Erwerb chirurgischer Basistechniken durch "blended learning"

    Get PDF
    Zusammenfasssung: Hintergrund: Große Studierendenzahlen und heterogene Dozierende erschweren einheitliche Kursgestaltungen und die objektive Standardisierung von Prüfungen im chirurgischen Fertigkeitstraining. Diese Arbeit zeigt die Vorteile des Einsatzes neuer Medien im "Blended-learning-Konzept" für das Fertigkeitstraining im Studiengang Humanmedizin der Universität Basel. Material und Methoden: Der studentische chirurgische "Nahtkurs" wurde nach einem Blended-learning-Konzept mit multimedialer CD, Präsenzveranstaltung und SkillsLab restrukturiert. Die Lernziele des Kurses wurden am Ende der Studienjahre anhand von Posten mit Checklisten im OSCE ("objective structured clinical examination") überprüft. Die studentische Kursbeurteilung sowie die Prüfungsergebnisse vor und nach Einführung des "blended learning" wurden miteinander verglichen. Ergebnisse: Sowohl die Beurteilungen der eingesetzten Lehrmittel, des subjektiven Übungserfolges und des prospektiven Nutzens für das Wahlstudienjahr (Praktisches Jahr) als auch die Gesamtkursbeurteilung waren nach Einführung des Blended-learning-Konzeptes signifikant höher als im alten Kursformat. Auch der Anteil an bestandenen Prüfungen war mit einem Zuwachs von 10% signifikant im Vergleich zum alten Kurs erhöht. Schlussfolgerung: "Blended learning” kann sowohl Wahrnehmung und Leistung als auch die Effizienz des Fertigkeitstrainings und der Betreuungszeit verbessern. Dadurch werden indirekt Ressourcen gespart. Chirurgische Verfahren können klar und übersichtlich vermittelt werde

    The barrel DIRC of PANDA

    Get PDF
    Cooled antiproton beams of unprecedented intensities in the momentum range of 1.5-15 GeV/c will be used for the PANDA experiment at FAIR to perform high precision experiments in the charmed quark sector. The PANDA detector will investigate antiproton annihilations with beams in the momentum range of 1.5 GeV/c to 15 GeV/c on a fixed target. An almost 4π acceptance double spectrometer is divided in a forward spectrometer and a target spectrometer. The charged particle identification in the latter is performed by ring imaging Cherenkov counters employing the DIRC principle
    corecore