1,327 research outputs found
Design Optimization for Shear Key on the TF Coil Structure of the KSTAR Tokamak
The KSTAR tokamak is comprised of a magnet system, vacuum vessel, and cryostat, thereby facilitating vacuum conditions for plasma gas at high temperatures, along with low-temperature helium gas for cooling. The TF coil structure, a part of the magnet system, is constructed and jointed with 16 pieces at 22.5-degree intervals using a conical bolt and shear key. The main function of the shear key in the inner and outer inter-coil structures is to resist in-plane and out-of-plane forces and to increase the shear stiffness for the inter coil structures. However, since the shape of the shear key is difficult to produce and can incur high costs, the shear key needs to be dimensionally optimized to regularize the stress between the key and the structure. Accordingly, shape optimization of the shear key was carried out using the Taguchi method and the stresses analyzed by ANSYS
Time and Amplitude of Afterpulse Measured with a Large Size Photomultiplier Tube
We have studied the afterpulse of a hemispherical photomultiplier tube for an
upcoming reactor neutrino experiment. The timing, the amplitude, and the rate
of the afterpulse for a 10 inch photomultiplier tube were measured with a 400
MHz FADC up to 16 \ms time window after the initial signal generated by an LED
light pulse. The time and amplitude correlation of the afterpulse shows several
distinctive groups. We describe the dependencies of the afterpulse on the
applied high voltage and the amplitude of the main light pulse. The present
data could shed light upon the general mechanism of the afterpulse.Comment: 11 figure
Neutron beam test of CsI crystal for dark matter search
We have studied the response of Tl-doped and Na-doped CsI crystals to nuclear
recoils and 's below 10 keV. The response of CsI crystals to nuclear
recoil was studied with mono-energetic neutrons produced by the
H(p,n)He reaction. This was compared to the response to Compton
electrons scattered by 662 keV -ray. Pulse shape discrimination between
the response to these 's and nuclear recoils was studied, and quality
factors were estimated. The quenching factors for nuclear recoils were derived
for both CsI(Na) and CsI(Tl) crystals.Comment: 21pages, 14figures, submitted to NIM
Scintillation-only Based Pulse Shape Discrimination for Nuclear and Electron Recoils in Liquid Xenon
In a dedicated test setup at the Kamioka Observatory we studied pulse shape
discrimination (PSD) in liquid xenon (LXe) for dark matter searches. PSD in LXe
was based on the observation that scintillation light from electron events was
emitted over a longer period of time than that of nuclear recoil events, and
our method used a simple ratio of early to total scintillation light emission
in a single scintillation event. Requiring an efficiency of 50% for nuclear
recoil retention we reduced the electron background to 7.7\pm1.1(stat)\pm1.2
0.6(sys)\times10-2 at energies between 4.8 and 7.2 keVee and to
7.7\pm2.8(stat)\pm2.5 2.8(sys)\times10-3 at energies between 9.6 and 12 keVee
for a scintillation light yield of 20.9 p.e./keV. Further study was done by
masking some of that light to reduce this yield to 4.6 p.e./keV, the same
method results in an electron event reduction of 2.4\pm0.2(stat)\pm0.3
0.2(sys)\times10-1 for the lower of the energy regions above. We also observe
that in contrast to nuclear recoils the fluctuations in our early to total
ratio for electron events are larger than expected from statistical
fluctuations.Comment: 25 pages, 15 figure
Search for solar axions in XMASS, a large liquid-xenon detector
XMASS, a low-background, large liquid-xenon detector, was used to search for
solar axions that would be produced by bremsstrahlung and Compton effects in
the Sun. With an exposure of 5.6ton days of liquid xenon, the model-independent
limit on the coupling for mass 1keV is
(90% C.L.), which is a factor of two stronger than the existing experimental
limit. The bounds on the axion masses for the DFSZ and KSVZ axion models are
1.9 and 250eV, respectively. In the mass range of 10-40keV, this study produced
the most stringent limit, which is better than that previously derived from
astrophysical arguments regarding the Sun to date
Carrier-mediated ferromagnetic ordering in Mn ion-implanted p+GaAs:C
Highly p-type GaAs:C was ion-implanted with Mn at differing doses to produce
Mn concentrations in the 1 - 5 at.% range. In comparison to LT-GaAs and
n+GaAs:Si samples implanted under the same conditions, transport and magnetic
properties show marked differences. Transport measurements show anomalies,
consistent with observed magnetic properties and with epi- LT-(Ga,Mn)As, as
well as the extraordinary Hall Effect up to the observed magnetic ordering
temperature (T_C). Mn ion-implanted p+GaAs:C with as-grown carrier
concentrations > 10^20 cm^-3 show remanent magnetization up to 280 K
Low energy fast events from radon progenies at the surface of a CsI(Tl) scintillator
In searches for rare phenomena such as elastic scattering of dark matter
particles or neutrinoless double beta decay, alpha decays of Rn222 progenies
attached to the surfaces of the detection material have been identified as a
serious source of background. In measurements with CsI(Tl) scintillator
crystals, we demonstrate that alpha decays of surface contaminants produce fast
signals with a characteristic mean-time distribution that is distinct from
those of neutron- and gamma-induced events.Comment: 9 pages, 8 figure
Non-linear electrical response in a charge/orbital ordered CaMnO crystal : the charge density wave analogy
Non-linear conduction in a charge-ordered manganese oxide
PrCaMnO is reported. To interpret such a feature, it is
usually proposed that a breakdown of the charge or orbitally ordered state is
induced by the current. The system behaves in such a way that the bias current
may generate metallic paths giving rise to resistivity drop. One can describe
this feature by considering the coexistence of localized and delocalized
electron states with independent paths of conduction. This situation is
reminiscent of what occurs in charge density wave systems where a similar
non-linear conduction is also observed. In the light of recent experimental
results suggesting the development of charge density waves in charge and
orbitally ordered manganese oxides, a phenomenological model for charge density
waves motion is used to describe the non-linear conduction in
PrCaMnO. In such a framework, the non-linear conduction
arises from the motion of the charge density waves condensate which carries a
net electrical current.Comment: 13 pages, 6 figure
Determining the Drift Time of Charge Carriers in P-Type Point-Contact HPGe Detectors
An algorithm to measure the drift time of charge carriers in p-type point
contact (PPC) high-purity germanium (HPGe) detectors from the signals processed
with a charge-sensitive preamplifier is introduced. It is demonstrated that the
drift times can be used to estimate the distance of charge depositions from the
point contact and to characterize losses due to charge trapping. A correction
for charge trapping effects over a wide range of energies is implemented using
the measured drift times and is shown to improve the energy resolution by up to
30%.Comment: 16 pages, 8 figures, submitted to Nucl. Instrum. Meth.
First limit on WIMP cross section with low background CsI(Tl) crystal detector
The Korea Invisible Mass Search (KIMS) collaboration has been carrying out
WIMP search experiment with CsI(T)crystal detectors at the YanYang
Underground Laboratory. A successful reduction of the internal background of
the crystal is done and a good pulse shape discrimination is achieved. We
report the first result on WIMP search obtained with 237 kgdays data
using one full-size CsI(T)crystal of 6.6 kg mass.Comment: 16 pages, 9 figures, submitted to Physics Letters
- …