230 research outputs found

    Daylighting Performance of Solar Control Films for Hospital Buildings in a Mediterranean Climate

    Get PDF
    One of the main retrofitting strategies in warm climates is the reduction of the effects of solar radiation. Cooling loads, and in turn, cooling consumption, can be reduced through the implementation of reflective materials such as solar control films. However, these devices may also negatively affect daylight illuminance conditions and the electric consumption of artificial lighting systems. In a hospital building, it is crucial to meet daylighting requirements as well as indoor illuminance levels and visibility from the inside, as these have a significant impact on health outcomes. The aim of this paper is to evaluate the influence on natural illuminance conditions of a solar control film installed on the windows of a public hospital building in a Mediterranean climate. To this end, a hospital room, with and without solar film, was monitored for a whole year. A descriptive statistical analysis was conducted on the use of artificial lighting, illuminance levels and rolling shutter aperture levels, as well as an analysis of natural illuminance and electric consumption of the artificial lighting system. The addition of a solar control film to the external surface of the window, in combination with the user-controlled rolling shutter aperture levels, has reduced the electric consumption of the artificial lighting system by 12.2%. Likewise, the solar control film has increased the percentage of annual hours with natural illuminance levels by 100–300 lux

    Indoor Air Quality Assessment: Comparison of Ventilation Scenarios for Retrofitting Classrooms in a Hot Climate

    Get PDF
    Current energy e ciency policies in buildings foster the promotion of energy retrofitting of the existing stock. In southern Spain, the most extensive public sector is that of educational buildings, which is especially subject to significant internal loads due to high occupancy. A large fraction of the energy retrofit strategies conducted to date have focused on energy aspects and indoor thermal comfort, repeatedly disregarding indoor air quality criteria. This research assesses indoor air quality in a school located in the Mediterranean area, with the objective of promoting di erent ventilation scenarios, based on occupancy patterns and carbon dioxide levels monitored on site. Results show that manual ventilation cannot guarantee minimum indoor quality levels following current standards. A constant ventilation based on CO2 levels allows 15% more thermal comfort hours a year to be reached, compared to CO2-based optimized demand-controlled ventilation. Nevertheless, the latter ensures 35% annual energy savings, compared to a constant CO2-based ventilation, and 37% more annual energy savings over that of a constant ventilation rate of outdoor air per person

    Solar Decathlon Latin America and Caribbean: Comfort and the Balance between Passive and Active Design

    Get PDF
    This article contains an overall analysis of the results obtained by the four highest scoring teams in the Solar Decathlon Latin America and Caribbean 2015 collegiate sustainable habitat competition. Considering that the prototypes developed were based on energy self-su ciency when operational, it was considered necessary to propose this analysis based on the degree of suitability of each of these models based on their di erent performances from the perspective of comfort conditions. It was observed that the design of the prototypes did not manage to properly adjust the relationship between passive and active conditioning elements based on the location’s conditions. Accordingly, this article concludes that a balance of the two aforementioned conditioning modes recorded better results based on the measurements taken

    Assessment of Indoor Environmental Quality for Retrofitting Classrooms with An Egg-Crate Shading Device in A Hot Climate

    Get PDF
    In the Mediterranean climate, a large number of educational buildings suffer from discomfort due mostly to energy-deficient thermal envelopes and a lack of cooling systems. Impending climate change is expected to worsen overheating in classrooms, especially during heatwave periods. Therefore, the protection of window openings to reduce incident solar radiation while maintaining adequate indoor environmental quality must be considered a necessary key focus. The main objective of this research is to assess the influence of an egg-crate shading device on the indoor environmental quality of a classroom in Southern Spain. To do so, two classrooms—with and without this shading device—were simultaneously monitored over a whole year. The implementation of an egg-crate shading device allowed for a significant reduction of the incident solar radiation, both in summer and mid-season (around 45–50%), which objectively slightly conditioned indoor operative temperatures. Given the noticeable influence of the user patterns observed, indoor illuminance was also improved, as the rolling shutters tended to be opened at higher aperture levels

    Thermal and Lighting Consumption Savings in Classrooms Retrofitted with Shading Devices in a Hot Climate

    Get PDF
    Most educational buildings in southern Spain do not meet current energy requirements as weak thermal envelopes and the lack of cooling systems lead to severe discomfort in classrooms, especially when temperatures are above 30 °C. Given that global warming is expected to worsen this situation in coming decades, one of the first steps to be taken is to protect window openings from high levels of solar radiation by adding shading devices to reduce indoor temperatures and improve visual comfort. The aim of this research is to evaluate the reduction in thermal and lighting consumption in a classroom where a solar protection system in the form of an egg-crate shading device was installed. Two classrooms—one with an egg-crate device and another with no shading system—were monitored and compared for a whole year. The use of an egg-crate device in these classrooms reduced indoor operative temperatures during warmer periods while also improving indoor natural illuminance levels. Moreover, annual electric air conditioning consumption decreased by approximately 20%, with a 50% reduction in electric lighting consumption. These savings in electricity were largely conditioned by the use patterns observed in these ambient systems.Spanish government BIA2014-53949-RMinistry of Economy and Competitiveness, Spanish GovernmentEuropean Regional Development Fun

    Assessment of Indoor Environmental Quality for Retrofitting Classrooms with An Egg-Crate Shading Device in A Hot Climate

    Get PDF
    In the Mediterranean climate, a large number of educational buildings suffer from discomfort due mostly to energy-deficient thermal envelopes and a lack of cooling systems. Impending climate change is expected to worsen overheating in classrooms, especially during heatwave periods. Therefore, the protection of window openings to reduce incident solar radiation while maintaining adequate indoor environmental quality must be considered a necessary key focus. The main objective of this research is to assess the influence of an egg-crate shading device on the indoor environmental quality of a classroom in Southern Spain. To do so, two classrooms—with and without this shading device—were simultaneously monitored over a whole year. The implementation of an egg-crate shading device allowed for a significant reduction of the incident solar radiation, both in summer and mid-season (around 45–50%), which objectively slightly conditioned indoor operative temperatures. Given the noticeable influence of the user patterns observed, indoor illuminance was also improved, as the rolling shutters tended to be opened at higher aperture levels

    Daylighting and Energy Performance Evaluation of an Egg-Crate Device for Hospital Building Retrofitting in a Mediterranean Climate

    Get PDF
    Hospital buildings present a significant savings potential in order to meet the objectives of H2020. The improvement of healthcare built environments contributes to improving the health of patients. In this respect, passive measurements must be prioritized, especially in relation to the weakest element of the building thermal enclosure: the window opening. Shading devices allow solar radiation and indoor temperature to be controlled, as well as improving visual comfort, mostly in buildings with a Mediterranean climate. This factor is of great importance when considering the increase in outdoor temperatures expected due to climate change. Unlike other studies in which predictive models are implemented, this paper examines a methodology based on the simultaneous monitoring of ambient variables, in real use and operative conditions, for two hospital rooms located in southern Spain. The aim of this research is to provide a comparative assessment of ambient conditions in a standard room with an egg-crate device and in a non-shaded one. The use of an egg-crate device allows a better yearly performance, improving natural illuminance levels, reducing incident solar radiation on the window, and decreasing artificial lighting consumption. However, its efficiency is greatly conditioned by the user patterns in relation to ambient systems, as the blind aperture level and the activation of the lighting system are directly controlled by users

    Transparent nanocellular PMMA: Characterization and modeling of the optical properties

    Get PDF
    In this work, the optical properties of transparent nanocellular polymethylmethacrylate (PMMA) have been studied, experimental and theoretically. Transmittance measurements of samples presenting different cell sizes (14, 24, 39 and 225 nm) and a constant relative density of around 0.45 have been carried out obtaining values as high as 0.94 for the sample with the smaller cell size and a thickness of 0.05 mm. In addition, the light absorption coefficient has been measured as a function of cell size and wavelength. It has been found that the transmittance has a strong dependence with the wavelength, presenting these transparent materials Rayleigh scattering. On the other hand, the transmission of visible light through these nanocellular materials has been modelled for the first time. The developed model reproduces with good accuracy the trends observed in the experimental results and provides remarkable insights into the physics mechanisms controlling the optical behavior of these materials

    Hygrothermal Performance of Worship Spaces: Preservation, Comfort, and Energy Consumption

    Get PDF
    The energy problem, one the most important on a global scale, greatly affects the environment. Much of the current energy consumption occurs in existing buildings, including heritage buildings with varying protected status. Energy intervention and heritage conservation conflict to some extent, as research focuses more on the search for improved energy efficiency solutions for materials and systems than on their application to heritage buildings. This study describes experimental research on environmental conditioning techniques in spaces of worship in a temperate climate in southern Spain. Buildings were monitored and assessed in the implementation of different environmental techniques—active and combined (passive and active)—with the aim of improving the thermal comfort conditions of the faithful while preserving the cultural heritage of these buildings. The need for a control system of RH and the air system was concluded, as well as radiant floors and radiators, which, in the considered case studies, would barely affect the artworks. 24- and 12-h operation are better suited to heritage preservation than occasional use. All operation schedules are valid for thermal comfort